Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Operate and monitor D.C. electrical systems
Operate and monitor D.C. electrical systems
Unit of competency
National Code
UEPOPS406
UEPOPS406
State Code
OAG58
OAG58
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
15/05/2019
Field of Education
031311 - Powerline Installation And Maintenance
Original Release Date
15/05/2019
Nominal Hours
18
Description
This unit involves the skills and knowledge required to operate and monitor local and remote operation of Direct Current (D.C.) electrical system including switchgears, ring mains, switchboards, rectification and distribution systems.Electrical systems in power generating facilities distribute electrical power to system components and provide electrical protection for power sources and components.Competency in this unit requires the ability to plan switching operations work, carry out operation of switch gears, switch boards and rectification systems,test switch gear and rectification equipment operation, analyse switch gear and rectification system equipment faults,inspect and monitor switch gear and switch board systems and the completion of all documentation. Individuals will, in general, work under supervision, in a power generation facility as an operator. Power generation plant operators are typically trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.Note: Workplace practiceThe application of the skills and knowledge described in this unit may require a licence or training permit to practice in the workplace where work is carried out on gas and electrical installations. Additional conditions may apply under state and territory legislative and regulatory licensing requirements.
Notes
Elements and Performance Criteria
1 Plan and prepare for switching operations
- 1.1 Safety issues related to operating and monitoring Direct Current (D.C.) electrical system plant are identified, in accordance with workplace procedures and Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations and legislative requirements
- 1.2 Work requirements are identified, in accordance with workplace procedures, from appropriate personnel and documentation
- 1.3 Documentation to determine D.C. electrical system plant status is assessed and evaluated, in accordance with workplace procedures
- 1.4 Equipment inspection, preoperational check and field preparation for D.C. electrical system service is carried out, in accordance with workplace procedures and manufacturers' recommendations procedures
- 1.5 Switchboard and equipment operational prerequisites and switching sequences are established, in accordance with workplace procedures and manufacturers' recommendations
2 Carry out operation of switchgears, switchboards and rectification systems
- 2.1 Operation of switchgear is carried out, in accordance with workplace procedures and manufacturers' recommendations
- 2.2 Isolation, removal and reinstatement of switchgear, switchboards and rectification systems are carried out, in accordance with workplace procedures and manufacturers' recommendations
- 2.3 Paralleling and balancing requirements are assessed, in accordance with workplace procedures, to meet D.C. electrical system stability
- 2.4 Rectification system is operated, isolated and reinstated, in accordance with workplace procedures and manufacturers' recommendations
3 Test switchgear and rectification equipment operation
- 3.1 Operational tests are performed, in accordance with workplace procedures
- 3.2 Switchgear and/or rectification system equipment is observed for correct operational response, in accordance with workplace procedures
- 3.3 Corrective action is taken, in accordance with workplace procedures, when response does not meet with documentation, D.C. electrical system integrity or personnel safety requirements
- 3.4 Switchgear and/or rectification system equipment is returned to required operational status upon completion of testing, in accordance with workplace procedures
4 Analyse system, switchgear and rectification equipment faults
- 4.1 Causes of abnormal D.C. electrical system and switchgear operating conditions are identified, in accordance with workplace procedures, and by analysing technical and operational information
- 4.2 Corrective action is taken, in accordance with workplace procedures
- 4.3 D.C. electrical system, and switchgear plant integrity and personnel safety are maintained, in accordance with workplace procedures, and in consultation with appropriate personnel and technical and operational documentation
5 Inspect and monitor system and switchboards
- 5.1 D.C. electrical system and switchgear to be monitored and inspected is physically identified, in accordance with workplace procedures
- 5.2 D.C. electrical system and switchgear is monitored and inspected, in accordance with workplace procedures, for normal operation or to detect deviations
- 5.3 Corrective action is taken, in accordance with workplace procedures
- 5.4 Appropriate personnel are notified, in accordance with workplace procedures, when defects and abnormal operating conditions are detected
6 Complete documentation
- 6.1 Equipment problems and status are reported, in accordance with workplace procedures
- 6.2 Documentation is updated, in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WE392 | UEPOPS406B | Operate and monitor d.c. electrical systems | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| ODZ29 | UEPOPS089 | Operate and monitor d.c. electrical systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BEB6 | UEP40218 | Certificate IV in ESI Generation - Operations | Qualification |
| BEC3 | UEP50218 | Diploma of ESI Generation - Operations | Qualification |
| BEC0 | UEP40118 | Certificate IV in ESI Generation - Systems Operations | Qualification |
| BEB7 | UEP50118 | Diploma of ESI Generation - Systems Operations | Qualification |