Unit of competency Outline

Date retreived
23/07/2026 7:28 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Design and size consumer gas installations

Design and size consumer gas installations

Unit of competency
National Code
CPCPGS4011B
State Code
WF907
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
07/02/2013
State Implementation and Classification
Approved Date
27/03/2013
Field of Education
040327 - Plumbing
Original Release Date
27/03/2013
Nominal Hours
38
Description
This unit of competency specifies the outcomes required to design, size and document a consumer's gas installation, including consumer piping operating up to a pressure of 200kPa, fluing, ventilation and appliance installation associated with natural gas (NG), simulated natural gas (SNG), liquefied petroleum gas (LPG) and tempered liquefied petroleum gas (TLPG) for a building of minimum four floors and multiple buildings supplied through one gas source (billing meter or storage tank).It covers preparing for work, determining gas installation design requirements, detailed planning of the layout, and completing work finalisation processes, including records and documentation.
Notes
Elements and Performance Criteria
1 Prepare for planning.
  • 1.1 Nature and scope of planning task are identified and confirmed.
  • 1.2 Work health and safety (WHS) and environmental requirements associated with planning, sizing and documenting layout of gas installations are adhered to throughout the work.
  • 1.3 Work is organised and sequenced in conjunction with others involved in or affected by the work.
  • 1.4 Tools and equipmentrequired for planning, sizing and documenting layout of gas installations, including personal protective equipment, are selected and checked for serviceability, and faults are rectified or referred for action.
  • 1.5 Work area in which planning process is to be conducted is prepared.
2 Identify system requirements.
  • 2.1 Informationand specifications for required work are obtained and confirmed, if necessary by site inspection.
  • 2.2 Regulations and Australian standards relevant to the work are consulted and applied to all aspects of the work.
  • 2.3 Quantity, location and type of take-off materials and fixtures are determined from plans and specifications.
  • 2.4 Gas installations are sized according to relevant Australian standards, and statutory and regulatory authority and workplace requirements.
3 Plan system layout.
  • 3.1 Layout of gas installations is planned according to building plans, relevant Australian standards and workplace procedures.
  • 3.2 Materials required are specified and optimised according to relevant Australian standards from proposed design.
  • 3.3 Plans are recorded according to regulatory authorities' and workplace requirements.
  • 3.4 Sustainability principles and concepts are observed when preparing for and undertaking work process.
4 Restore work area.
  • 4.1 Work area is restored according to workplace procedures.
  • 4.2 Tools and equipment used in the process are refurbished and left according to workplace procedures.
  • 4.3 Information is accessed and documentation, including work backup, is completed according to workplace requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electrical components and safety
gas fires and explosions
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.

Environmental requirements may include:
air pollution
clean-up protection
environmental protection
waste management.

Gas installations may include:
liquefied petroleum gas
natural gas
simulated natural gas
tempered liquefied petroleum gas.

Tools and equipment may include:
computers running appropriate CAD software
drawing instruments
measuring equipment.

Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
gas regulations
WHS and environmental requirements
plumbing regulations
relevant Australian standards, including AS5601 Gas installations
safe work procedures relating to planning, sizing and documenting the layout of gas installations
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.

Statutory and regulatory authorities include:
commonwealth, state or territory, and local authorities administering applicable Acts, regulations and codes of practice.

Materials may include:
building plans and specifications.

Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
use of efficient design principles to ensure minimal environmental impact
incorporation of efficient use of material into the design, including recycling of material
choice of efficient energy and water appliances
correct handling of hazardous materials
disposing of waste material to ensure minimal environmental impact.



The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.

Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, relevant Australian standards and specifications to the planning, sizing and layout of gas installations
applying safety requirements throughout the work sequence, including electrical safety requirements and the use of personal protective clothing and equipment
designing, sizing and documenting the layout of three gas installations, which are to include any combinations covering:
pipe sizing and pressures up to 200kPa
at least one NG installation
at least one LPG installation
at least one domestic installation
at least one commercial installation
a caravan installation
a marine installation, including the installation of an LPG leak detection system in a mono hull vessel
installations planned and documented must include:
multiple buildings
a two stage LPG system
five or more gas appliances
domestic and commercial Type A gas appliances
a common flue system
a minimum of three piping materials
an over-pressure protection device
a subsidiary meter
plans and documentation should ensure:
application of sustainability principles and concepts
identification, evaluation and incorporation of sustainability principles and concepts into the design
correct identification of location, design and details of proposed services
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, relevant Australian standards and organisational quality procedures and processes
communicating and working effectively and safely with others.

Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.

Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.



Replaces
State Code National Code Title Type
D7463 CPCPGS4011A Design and size consumer gas installations Unit of competency
Replaced By
State Code National Code Title Type
WI775 CPCPGS4011C Design and size consumer gas installations Unit of competency
State Code National Code Title Type
J491 CPC32412 Certificate III in Plumbing Qualification