Unit of competency Outline
Date retreived
22/07/2026 6:45 PM AWST
22/07/2026 6:45 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install WiMAX customer premises equipment broadband wireless access equipment
Install WiMAX customer premises equipment broadband wireless access equipment
Unit of competency
National Code
ICTRFN3146A
ICTRFN3146A
State Code
D3400
D3400
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
15/04/2014
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
15/04/2014
Nominal Hours
35
Description
This unit describes the performance outcomes, skills and knowledge required to install and set up worldwide interoperability for microwave access (WiMAX) customer premises equipment (CPE) in homes and commercial premises.No licensing, legislative, regulatory or certification requirements apply to this unit at the time of endorsement but users should confirm requirements with the relevant federal, state or territory authority.
Notes
Elements and Performance Criteria
1. Prepare for WiMAX equipment installation
- 1.1. Arrange access to the site according to required procedure
- 1.2. Verify customerrequirements, type of WiMAX CPE equipment and location of proposed installation according to the plans obtained from authorised personnel
- 1.3. Prepare tools, equipment and CPE required for installation
2. Install the outdoor unit and antenna
- 2.1. Make worksite safe by identifying existing and potential hazards
- 2.2. Comply with relevant legislation, codes, regulations and standards, occupational health and safety (OHS) and environmental requirements
- 2.3. Mount the outdoor unit according to manufacturer's specifications and enterprise plans
- 2.4. Connect the outdoor unit to the indoor unit using specified cable
- 2.5. Position the antenna towards the distant WiMAX base station for preliminary orientation
- 2.6. Align the unit for maximum signal strength using received signal strength indication (RSSI) display
- 2.7. Record the installation and alignment details
- 2.8. Connect indoor unit and accessories to customer equipment
3. Test the performance of the installation
- 3.1. Test WiMAX CPE according to manufacturer's procedures
- 3.2. Check operating environment does not degrade test results
- 3.3. Evaluate test results to verify operational performance with customer
4. Restore site and complete documentation
- 4.1. Restore worksite to the customer's satisfaction
- 4.2. Complete reports on installation
- 4.3. Notify customer and obtain sign off
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Customer requirements may include:
backup procedures
bandwidth
congestion
network connectivity
power back up
quality of service (QoS)
redundancy
wireless access.
WiMAX CPE equipment may include:
indoor unit
outdoor unit
USB unit.
Authorised personnel may include:
customer
network administrator
network planner
project manager
supervisor.
Tools may include:
crimping tool
cable stripping tool
drill bits
screwdrivers
spanner
wall anchors and screws.
Equipment may include:
compass
global positioning system (GPS)
inclinometer
laptop.
Hazards may include:
building debris
earth potential rise
glass fibre
live power lines
manual handling
radio frequency (RF) equipment emitting radiation.
Relevant legislation, codes, regulations and standards may include:
Australian Communications Industry Forum (ACIF) standards and codes
Australian Communications and Media Authority (ACMA) technical standards
Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) electromagnetic radiation (EMR) standard
AS/NZS 4268:2008
AS/NZS 4295:2004
AS/NZS 4415.1:2003
AS/NZS 4582:1999
AS/NZS 4583:1999
AS/NZS 4769.1:2000
AS/NZS 4770:2000
Australian building codes and regulations
Australian standards
enterprise standards
environmental protection
equipment standards
European Telecommunications Standards Institute (ETSI) EN 300 220-1
ETSI EN 301 406
fire regulations
heritage legislation
international standards
intrinsically safe lightning protection
local government
OHS
Radcoms Act
RSS-119
site engineering standards
spectrum planning reports
Telecommunications Act
Telecommunications Industry Alliance and Electronic Industries Alliance (TIA/EIA) standards.
OHS and environmental requirements may relate to:
decommissioning and isolating worksite and lines prior to commencement
identifying other services, including power and gas
personal protective clothing:
earmuffs
gloves:
plastic
rubber
leather
head protection
head protection
kneepads
masks
protective suits
safety boots
safety glasses
safety harness
safety line
safe working practices, such as the safe use and handling of:
asbestos
chemicals
materials
tools and equipment
work platforms
safety equipment:
flashing lights
gas and other hazard detection equipment
safety barriers
trench guards
warning signs and tapes
witches hats
special access requirements
suitable light and ventilation
environmental considerations:
clean-up protection
stormwater protection
waste management.
Indoor unit and accessories may include:
correct cable:
crossover
straight-through
optional extension module:
voice over internet protocol (VoIP)
wireless fidelity (WiFi)
power unit:
AC power
DC power adaptor
DC power supply
protection device:
lightning protection
surge protection.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Customer requirements may include:
backup procedures
bandwidth
congestion
network connectivity
power back up
quality of service (QoS)
redundancy
wireless access.
WiMAX CPE equipment may include:
indoor unit
outdoor unit
USB unit.
Authorised personnel may include:
customer
network administrator
network planner
project manager
supervisor.
Tools may include:
crimping tool
cable stripping tool
drill bits
screwdrivers
spanner
wall anchors and screws.
Equipment may include:
compass
global positioning system (GPS)
inclinometer
laptop.
Hazards may include:
building debris
earth potential rise
glass fibre
live power lines
manual handling
radio frequency (RF) equipment emitting radiation.
Relevant legislation, codes, regulations and standards may include:
Australian Communications Industry Forum (ACIF) standards and codes
Australian Communications and Media Authority (ACMA) technical standards
Australian Radiation Protection and Nuclear Safety Agency (ARPANSA) electromagnetic radiation (EMR) standard
AS/NZS 4268:2008
AS/NZS 4295:2004
AS/NZS 4415.1:2003
AS/NZS 4582:1999
AS/NZS 4583:1999
AS/NZS 4769.1:2000
AS/NZS 4770:2000
Australian building codes and regulations
Australian standards
enterprise standards
environmental protection
equipment standards
European Telecommunications Standards Institute (ETSI) EN 300 220-1
ETSI EN 301 406
fire regulations
heritage legislation
international standards
intrinsically safe lightning protection
local government
OHS
Radcoms Act
RSS-119
site engineering standards
spectrum planning reports
Telecommunications Act
Telecommunications Industry Alliance and Electronic Industries Alliance (TIA/EIA) standards.
OHS and environmental requirements may relate to:
decommissioning and isolating worksite and lines prior to commencement
identifying other services, including power and gas
personal protective clothing:
earmuffs
gloves:
plastic
rubber
leather
head protection
head protection
kneepads
masks
protective suits
safety boots
safety glasses
safety harness
safety line
safe working practices, such as the safe use and handling of:
asbestos
chemicals
materials
tools and equipment
work platforms
safety equipment:
flashing lights
gas and other hazard detection equipment
safety barriers
trench guards
warning signs and tapes
witches hats
special access requirements
suitable light and ventilation
environmental considerations:
clean-up protection
stormwater protection
waste management.
Indoor unit and accessories may include:
correct cable:
crossover
straight-through
optional extension module:
voice over internet protocol (VoIP)
wireless fidelity (WiFi)
power unit:
AC power
DC power adaptor
DC power supply
protection device:
lightning protection
surge protection.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
install and test WiMAX CPE outdoor unit
install indoor unit and connect to customer network
reinstate site, document and complete installation reports.
Context of and specific resources for assessment
Assessment must ensure:
sites on which WiMAX installations can be conducted
tools and equipment required for installation
relevant regulatory and equipment documentation..
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
review of a hands-on project completed by the candidate
review of an oral and written report with completed documentation
direct observation of the candidate installing and connecting WiMAX CPE equipment.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTDRE3165A Install a complex digital reception system
ICTRFN4095A Conduct radio frequency measurements.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
install and test WiMAX CPE outdoor unit
install indoor unit and connect to customer network
reinstate site, document and complete installation reports.
Context of and specific resources for assessment
Assessment must ensure:
sites on which WiMAX installations can be conducted
tools and equipment required for installation
relevant regulatory and equipment documentation..
Method of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
review of a hands-on project completed by the candidate
review of an oral and written report with completed documentation
direct observation of the candidate installing and connecting WiMAX CPE equipment.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTDRE3165A Install a complex digital reception system
ICTRFN4095A Conduct radio frequency measurements.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AWD97 | ICTRFN303 | Install WiMAX customer premises equipment broadband wireless access equipment | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J814 | ICT30113 | Certificate III in Broadband and Wireless Networks Technology | Qualification |