Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Conduct compliance inspection of single phase LV electrical installations
Conduct compliance inspection of single phase LV electrical installations
Unit of competency
National Code
UEEEL0030
UEEEL0030
State Code
OBZ79
OBZ79
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
54
Description
This unit involves the skills and knowledge required to conduct compliance inspection of single phase low voltage (LV) electrical installation.It includes preparing and conducting compliance inspections, and actioning and reporting on inspection findings.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 volt (V) alternating (a.c.) or 120 V direct current (d.c.)Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, a relevant contract of training, such as an Australian Apprenticeship, may be required. Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to conduct compliance inspection
- 1.1 WHS/OHS procedures for a given work area are identified, obtained and applied
- 1.2 WHS/OHS risk control measures and procedures in preparation for the work are followed
- 1.3 WHS/OHS hazards not previously identified are noted, risks assessed, and risk control measures implemented in consultation with appropriate person/s
- 1.4 Installation documentation and/or relevant industry standard for the installation is reviewed and applied
- 1.5 Appropriate person/s is consulted to ensure the work is coordinated effectively with others
- 1.6 Tools, equipment and testing devices to verify compliance are obtained in accordance with workplace procedures and checked for operation and safety
2 Conduct compliance inspection
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out the work are followed
- 2.2 Need to test and measure live electrical work is conducted in accordance with WHS/OHS requirements and workplace procedures
- 2.3 Circuits/machines/plant are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
- 2.4 Inspection of the mains and main switchboard is conducted for compliance of protection metering earthing circuit arrangements and markings in accordance with relevant industry standards
- 2.5 Inspection of circuits is conducted for compliance of the installed wiring accessories switchgear/control gear and current-using devices in accordance with relevant industry standards
- 2.6 Evidence electrical equipment complies with safety requirements is sought from appropriate person/s and sighted
- 2.7 Inspection is conducted to verify compliance of earthing insulation polarity circuit connections and operation of residual current devices (RCDs) in accordance with relevant industry standards
- 2.8 Fault-loop impedance is determined as being sufficiently low by testing calculation and compliance with arrangement of the installation in accordance with relevant industry standards
- 2.9 Unplanned events are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
3 Act and report on inspection findings
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Non-compliance defects are identified and documented in accordance with relevant industry standards and workplace established procedures
- 3.3 Actions are taken for non-compliance defects within the scope of inspection responsibilities in accordance with workplace procedures and relevant industry standards
- 3.4 Inspection report is completed and issued to appropriate person/s in accordance with workplace procedures and relevant industry standards
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WC480 | UEENEEG122A | Conduct compliance inspection of single phase LV electrical installations | Unit of competency |