Unit of competency Outline
Date retreived
22/07/2026 7:32 PM AWST
22/07/2026 7:32 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Design energy management controls for electrical installations in buildings
Design energy management controls for electrical installations in buildings
Unit of competency
National Code
UEERE0010
UEERE0010
State Code
OBY69
OBY69
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031301 - Electrical Engineering
Original Release Date
12/07/2021
Nominal Hours
72
Description
This unit involves the skills and knowledge required to design energy management controls for electrical installations in new buildings/structures.It includes designing and developing energy management control methods to reduce energy use in new buildings/structures, and documenting strategies to effectively reduce energy use in the completed installation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Identify energy management techniques for electrical installations in buildings
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) processes and workplace procedures for a given work area are identified, obtained and applied
- 1.2 Hazards are identified, WHS/OHS risks assessed, and control measures and workplace procedures are implemented in preparation for work
- 1.3 Scope of the energy management electrical design is determined from specifications of building and its services, plant and machinery and in consultation with relevant person/s
- 1.4 Advice is sought from allied trade areas and component suppliers on required energy usage and system design in accordance with manufacturer specifications on energy usage for electrical control system
- 1.5 Advice is sought from work supervisor to ensure work is coordinated effectively with relevant person/s
- 1.6 Tools, testing devices and materials needed to carry out work are obtained and checked for correct operation and safety
2 Design energy management controls for electrical installations
- 2.1 WHS/OHS risk control measures and workplace procedures for carrying out work are followed
- 2.2 Inspection, tests and measurements are carried out in accordance with WHS/OHS requirements and workplace procedures
- 2.3 Energy use of building services, plant and machinery is obtained and applied to the energy management design control process
- 2.4 Energy evaluation tests are set up in accordance with inspection and test methods and workplace procedures
- 2.5 Strategies to reduce electrical system energy use without compromising occupancy standards are developed in accordance with energy management techniques and evaluation test results
- 2.6 Unexpected situations are dealt with safely and effectively in accordance with workplace procedures and approval relevant person
- 2.7 Design and electrical installation evaluation is carried out without unnecessary damage to systems circuits, the surrounding environment or services using sustainable energy practices
3 Document energy management strategies to effectively reduce energy use in building
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
- 3.3 Results of energy management design controls, recommended electrical installation strategies and their criterion for energy reduction are documented in accordance with workplace procedures
- 3.4 Plans, wiring diagrams and specifications are completed and forwarded to relevant person/s
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WC715 | UEENEEK146A | Design energy management controls for electrical installations in buildings | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OEU37 | UEERE0059 | Design energy management controls for electrical installations in buildings | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFK9 | UEE63020 | Advanced Diploma of Electrical Systems Engineering | Qualification |
| BFN8 | UEE62120 | Advanced Diploma of Engineering Technology - Electrical | Qualification |
| BHZ3 | UEE62122 | Advanced Diploma of Engineering Technology - Electrical | Qualification |
| BFM3 | UEE62020 | Advanced Diploma of Engineering Technology - Renewable Energy | Qualification |
| BFJ7 | UEE60920 | Advanced Diploma of Renewable Energy Engineering | Qualification |
| AE242 | UEESS00165 | Sustainable - Energy Efficiency Systems Designer Skill Set | Skill set |
| AE233 | UEESS00166 | Sustainable - Energy Efficiency Systems Developer Skill Set | Skill set |