Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Design residential and domestic fire sprinkler systems
Design residential and domestic fire sprinkler systems
Unit of competency
National Code
CPCPFS4024A
CPCPFS4024A
State Code
WF886
WF886
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
20/06/2014
Field of Education
039905 - Fire Technology
Original Release Date
20/06/2014
Nominal Hours
96
Description
This unit of competency specifies the outcomes required to design domestic and residential fire sprinkler systems using hydraulic calculations.It covers preparation for the work, determination of system requirements, detailed design and recording of system plans, and work finalisation processes.
Notes
Elements and Performance Criteria
1 Prepare for design process.
- 1.1 Nature and scope of design task are identified and confirmed.
- 1.2 Work health and safety (WHS) andenvironmental requirements associated with designing residential and domestic fire sprinkler systems areadhered to throughout the work.
- 1.3 Quality assurance requirements are identified and adhered to according to workplace requirements.
- 1.4 Work is organised and sequenced in conjunction with others involved in or affected by the work.
- 1.5 Tools, equipmentand materials required for designing domestic and residential fire sprinkler systems, including personal protective equipment, are selected and checked for serviceability.
- 1.6 Work area in which the design process is to be conducted is prepared.
2 Determine system requirements.
- 2.1 Informationand specifications for the required work are obtained and confirmed, if necessary by site inspection.
- 2.2 Regulations and standards relevant to the work are consulted and applied to all aspects of the work.
- 2.3 Relevant data is extracted from plans and specifications.
- 2.4 Building classification and hazard ratings are established according to standards and other relevant regulations.
3 Design sprinkler system.
- 3.1 Water supply needs are established and graphs are drawn for the automatic fire sprinkler system.
- 3.2 Pipework is sized to manufacturer specifications and standards using hydraulic calculations.
- 3.3 Sprinkler system is designed to meet plans, specifications, standards, manufacturer recommendations and water supply data.
- 3.4 Sprinkler heads are selected for appropriate size, spray pattern, temperature and finish.
- 3.5 Sprinklers are spaced according to manufacturer specifications, standards and relevant statutory and regulatory authority regulations.
- 3.6 Pipe layout drawings are prepared according to standards and workplace requirements.
- 3.7 Computations and other supporting evidence are appropriately documented to support design.
- 3.8 Materials required are specified and optimised according to standards from the proposed design.
- 3.9 Fabrication sheets and material lists are prepared.
- 3.10 Plans are recorded according to regulatory authorities' and workplace requirements.
- 3.11 Sustainability principles and concepts are observed when preparing for and undertaking work process.
4 Restore work area.
- 4.1 Work area is cleared and materials disposed of, reused or recycled according to legislation, regulations, codes of practice and job specification.
- 4.2 Tools and equipment used in the design process are refurbished and left according to workplace procedures.
- 4.3 Information is accessed and documentation, including work backup, is completed according to workplace requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
calculators
design data
design tables
drawing and drafting equipment
reference materials
computers running appropriate computer-aided design (CAD) software.
Materials may include:
drafting materials
plans.
Domestic and residential fire sprinkler systems may include:
actuating devices
alarms
control valve assemblies
piping
sprinkler heads.
Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing regulations
relevant Australian standards, including AS2118 Automatic fire sprinkler systems
safe work procedures relating to designing domestic and residential fire sprinkler systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Statutory and regulatory authorities include:
commonwealth, state or territory, and local authorities administering applicable Acts, regulations and codes of practice.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
efficient energy use
efficient use and recycling of material
selecting appropriate components (sprinkler head, pump, etc.) to ensure minimal environmental impact.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
calculators
design data
design tables
drawing and drafting equipment
reference materials
computers running appropriate computer-aided design (CAD) software.
Materials may include:
drafting materials
plans.
Domestic and residential fire sprinkler systems may include:
actuating devices
alarms
control valve assemblies
piping
sprinkler heads.
Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing regulations
relevant Australian standards, including AS2118 Automatic fire sprinkler systems
safe work procedures relating to designing domestic and residential fire sprinkler systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Statutory and regulatory authorities include:
commonwealth, state or territory, and local authorities administering applicable Acts, regulations and codes of practice.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
efficient energy use
efficient use and recycling of material
selecting appropriate components (sprinkler head, pump, etc.) to ensure minimal environmental impact.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to the design of domestic and residential fire sprinkler systems
applying safety requirements throughout the work sequence, including electrical safety requirements and the use of personal protective clothing and equipment
using hydraulic calculations, designing a fire sprinkler system for a residential complex containing a minimum of a communal catering and living area and multiple residential quarters (or equivalent) and also a fire sprinkler system for a domestic residence containing a minimum of two rooms, ensuring:
application of sustainability principles and concepts
correct identification of location, design specification and details of proposed service
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to the design of domestic and residential fire sprinkler systems
applying safety requirements throughout the work sequence, including electrical safety requirements and the use of personal protective clothing and equipment
using hydraulic calculations, designing a fire sprinkler system for a residential complex containing a minimum of a communal catering and living area and multiple residential quarters (or equivalent) and also a fire sprinkler system for a domestic residence containing a minimum of two rooms, ensuring:
application of sustainability principles and concepts
correct identification of location, design specification and details of proposed service
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| D7452 | CPCPFS4014A | Design residential and domestic fire sprinkler systems | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OCN98 | CPCPFS4024 | Design residential fire sprinkler systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J499 | CPC50612 | Diploma of Hydraulic Services Design | Qualification |
| J497 | CPC40912 | Certificate IV in Plumbing and Services | Qualification |