Unit of competency Outline
Date retreived
22/07/2026 1:41 PM AWST
22/07/2026 1:41 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Shut down a boiler unit
Shut down a boiler unit
Unit of competency
National Code
UEPOPS133
UEPOPS133
State Code
ODY10
ODY10
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
14/04/2023
Field of Education
030717 - Plant And Machine Operations
Original Release Date
14/04/2023
Nominal Hours
54
Description
This unit involves the skills and knowledge required to conduct the shutdown of a boiler unit to a depressurised state.A shutdown of a boiler unit will involve a series of steps to stop production, feed and fuel flows in a safe and controlled manner.Competency in this unit requires the ability to plan and prepare boiler unit shutdown, conduct a shutdown, test boiler unit operation during shutdown, analyse boiler unit system faults during shutdown and complete documentation post-shutdown. Individuals will, in general, work under supervision in a power generation facility as an operator.Power generation plant operators are trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Plan and prepare boiler unit shutdown work
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) regulations, legislative requirements, codes of practice, manufacturers’ recommendations and specifications, environmental requirements and workplace procedures are identified, applied and monitored
- 1.2 Work requirements are identified from relevant personnel and documentation in accordance with workplace procedures
- 1.3 Preoperational checks are carried out on boiler unit plant in accordance with manufacturers' recommendations and specifications, and workplace procedures
2 Conduct boiler unit shutdown
- 2.1 Perform shutdown of boiler unit in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 2.2 Boiler unit is cooled down and purged in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 2.3 Boiler unit is depressurised in accordance with manufacturers' recommendations and specifications, and workplace procedures
- 2.4 Corrective actions are taken to rectify boiler unit abnormalities in accordance with manufacturers' recommendations and specifications, and workplace procedures
3 Test boiler unitplant operation
- 3.1 Tests are performed on boiler unit in accordance with workplace procedures
- 3.2 Power generation system and boiler unit plant is observed for operational response in accordance with workplace procedures
- 3.3 Boiler unit plant is returned to required operational status upon completion of testing in accordance with workplace procedures
4 Analyse and report on system faults during boiler unit shutdown
- 4.1 Causes of abnormal boiler unit plant operating conditions are identified by analysing technical and operational information in accordance with workplace procedures
- 4.2 Boiler unit plant integrity and personnel safety is maintained through consultation with relevant personnel and technical and operational documentation in accordance with workplace procedures
- 4.3 Relevant personnel are notified when defects are detected in accordance with workplace procedures
5 Complete documentation
- 5.1 Boiler unit plant problems, movements and status are reported in accordance with workplace procedures
- 5.2 Documentation is updated in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAG55 | UEPOPS410 | Shut down a boiler unit | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BHQ2 | UEP40122 | Certificate IV in ESI Generation | Qualification |
| BHP9 | UEP50122 | Diploma of ESI Generation | Qualification |