Unit of competency Outline

Date retreived
22/07/2026 11:24 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Diagnose and repair pumping systems

Diagnose and repair pumping systems

Unit of competency
National Code
AURPTA011
State Code
AXB73
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
14/04/2016
State Implementation and Classification
Approved Date
13/07/2016
Field of Education
030503 - Vehicle Mechanics
Original Release Date
13/07/2016
Nominal Hours
30
Description
This unit describes the performance outcomes required to diagnose and repair faults in the pumping systems of outdoor power equipment according to manufacturer specifications. It involves preparing for the task, selecting the correct diagnostic procedure, carrying out the diagnosis and the repair, performing post-repair testing, and completing workplace processes and documentation.It applies to those working in the automotive service and repair industry. The pumping systems are those of outdoor power equipment and include:centrifugal pumps used for firefighting, irrigation and water transferdiaphragm pumps used in orchard sprayinghigh pressure piston pumps used for pressure cleanersNo licensing, legislative, regulatory or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Prepare to diagnose and repair outdoor power equipment pumping system
  • 1.1 Job requirements are determined from workplace instructions
  • 1.2 Diagnostic information is sourced and interpreted
  • 1.3 Diagnostic options are analysed and those most appropriate to the circumstances are selected
  • 1.4 Hazards associated with the work are identified and risks are managed
  • 1.5 Diagnostic tools and equipment are selected and checked for serviceability
2. Diagnose pumping system
  • 2.1 Diagnostic tests are carried out according to manufacturer specifications, workplace procedures and safety requirements
  • 2.2 Faults are identified from diagnostic test results and causes of faults are determined
  • 2.3 Diagnosis findings, including recommendations for necessary repairs or adjustments, are reported according to workplace procedures
  • 2.4 Obtain authorisation to proceed according to workplace procedures
3. Repair pumping system
  • 3.1 Repair information is sourced and interpreted
  • 3.2 Repair options are analysed and those most appropriate to the circumstances are selected
  • 3.3 Repair tools, equipment and materials are selected and checked
  • 3.4 Repairs and component replacements and adjustments are carried out according to manufacturer specifications, workplace procedures and safety requirements, and without causing damage to components or systems
  • 3.5 Post-repair testing is carried out according to workplace procedures to confirm fault rectification, and any further problems detected as having been introduced during the repair process are rectified
4. Complete work processes
  • 4.1 Final inspection is made to ensure work is to workplace expectations and system is presented ready for use, including protective guards, cowlings and safety features
  • 4.2 Work area is cleaned, waste and non-recyclable materials are disposed of, and recyclable material is collected
  • 4.3 Tools and equipment are checked and stored according to workplace procedures
  • 4.4 Workplace documentation is processed according to workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WF303 AURPTA3011 Repair pumping systems Unit of competency
Replaced By
State Code National Code Title Type
OCI80 AURPTA111 Diagnose and repair pumping systems Unit of competency