Unit of competency Outline
Date retreived
22/07/2026 2:58 PM AWST
22/07/2026 2:58 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Develop and manage periodic electrical inspection and maintenance programs for hazardous areas
Develop and manage periodic electrical inspection and maintenance programs for hazardous areas
Unit of competency
National Code
UEEHA0009
UEEHA0009
State Code
OCB27
OCB27
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
18
Description
This unit involves the skills and knowledge required to develop and manage the explosion-protection aspects for periodic electrical inspections and maintenance schemes. It includes understanding of the provisions of the applicable hazardous area standards in relation to area classification or equipment protection levels (EPLs) and selection and installation of electrical equipment; understanding of repair and reclamation of equipment; determining the frequency and grades of inspections and levels of maintenance required; and specifying and overseeing the inspection and maintenance processes to be followed and maintaining the required documentation in the verification dossier. It is adopted from clause 2.9 of AS/NZS 4761.1:2018 Competencies for working with electrical equipment for hazardous areas (EEHA).This unit applies to technical management and maintenance functions.Site-specific work permits maybe required to work in the hazardous environment. In addition, other permits may be required, such as confined space and to operate specific pieces of equipment such as elevated work platforms (EWPs) in various jurisdictions.Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Establish inspection and maintenance requirements
- 1.1 Understanding of the provisions of hazardous area standards applicable to area classification, electrical installation design, selection and installation, and repair and reclamation of electrical equipment is applied to establishing the inspection and maintenance program
- 1.2 Documentation in the verification dossier is reviewed to ascertain the extent of hazardous areas, the area classifications and the electrical installation details and, for an existing site, previous inspection schedule and maintenance program records
- 1.3 The effect of external factors that may influence equipment integrity are assessed and included in establishing the types, grades and frequency inspections
2 Develop an inspection program for a hazardous area
- 2.1 Inspection schedules are developed from knowledge of the extent of the hazardous area and the electrical installation, the assessment of factors influencing equipment integrity and an understanding of the requirements and recommendations of standards and equipment manufacturers
- 2.2 Procedures for each grade of inspection are developed from recommendation of standards and equipment manufacturers and conditions particular to the site
- 2.3 A documentation system is developed for reporting inspection activities and identifying non-compliance defects and recommendations for maintenance
- 2.4 WHS/OHS policies and procedures are incorporated into the inspection and resulting maintenance program
3 Implement and evaluate the inspection and maintenance program
- 3.1 Qualifications of inspectors and maintenance personnel are reviewed to ensure they are currently competent to do the work
- 3.2 Periodic and sample inspection reports are used to develop maintenance programs and identify the need to revise the extent and frequency of inspections
- 3.3 Maintenance programs are established within the limits permitted for remedial maintenance in hazardous areas
- 3.4 Procedures are established for equipment identified as requiring repair or overhaul to be removed from service and sent to an accredited facility
- 3.5 Reports and other documentation related to the inspection and maintenance program activities are retained in the site verification dossier
No information
No information
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OEE80 | UEEHA0023 | Develop and manage periodic electrical inspection and maintenance programs for hazardous areas | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFM8 | UEE62220 | Advanced Diploma of Electrical - Engineering | Qualification |
| BFL9 | UEE62320 | Advanced Diploma of Electrical Engineering - Coal Mining | Qualification |
| BFM2 | UEE43020 | Certificate IV in Electrical Equipment and Systems | Qualification |
| BFP6 | UEE53020 | Diploma of Electrical Systems Engineering | Qualification |
| BFK9 | UEE63020 | Advanced Diploma of Electrical Systems Engineering | Qualification |
| BFM4 | UEE61220 | Advanced Diploma of Engineering - Explosion protection | Qualification |
| BFL5 | UEE42620 | Certificate IV in Hazardous areas - Electrical | Qualification |
| BFL3 | UEE60620 | Advanced Diploma of Industrial Electronics and Control Engineering | Qualification |