Unit of competency Outline
Date retreived
22/07/2026 2:40 PM AWST
22/07/2026 2:40 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Test copper rail signalling cables
Test copper rail signalling cables
Unit of competency
National Code
UEERS0019
UEERS0019
State Code
OBX67
OBX67
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
18
Description
This unit involves the skills and knowledge required to test signal and communication copper cables.It includes following workplace procedures, determining tools required, setting up and conducting tests, interpreting test results, determining activities to maintain system integrity and reporting activities.Persons achieving competence in this unit will need to fulfil the applicable state/territory legislated rail safety requirements and to comply with relevant codes of practice, rules and/or guidelines.No other licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to inspect and test rail signalling cable
- 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for work area are identified, obtained and applied
- 1.2 Hazards are identified, risks assessed, and control measures and workplace procedures implemented
- 1.3 Safety hazards that have not previously been identified are noted on the job safety assessments and existing risk control measures implemented
- 1.4 Access times and work methods are confirmed to comply with customer requirements and relevant rail safety legislation
- 1.5 Rail service access is checked prior to testing and signalling cable is isolated/disconnected from rail network/equipment to ensure no equipment damage can occur during testing
- 1.6 Required inspection, test procedures and purpose are identified from site, client, workplace documentation and manufacturer specifications
- 1.7 Tools and testing devices needed for cable testing are obtained in accordance with workplace procedures and checked for correct operation and safety
- 1.8 Testing devices calibration certification is checked and current in accordance with manufacturer specifications
2 Inspect and test rail signal cables
- 2.1 Work area and rail cable system is made safe for testing in accordance with WHS/OHS risk control measures and workplace procedures
- 2.2 Rail signal cables are inspected in accordance with workplace procedures and relevant specifications
- 2.3 Tests are set up and performed in accordance with safety risk control measures and manufacturer specifications
- 2.4 Test results are read accurately and compared against manufacturer and site specifications for rail cable performance
- 2.5 Existing methods for dealing with unplanned situations are dealt with safely in a manner that minimises risk to personnel and equipment and with the approval of an authorised person/s
- 2.6 Testing is performed efficiently without waste of materials or damage to apparatus, the surrounding environment or services in accordance with sustainable energy practices
- 2.7 Available services are connected and tested for functionality to ensure all previous services have been resumed
3 Report test results
- 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
- 3.2 Recommendations and required actions to maintain cable system integrity resulting from cable tests are reported and documented
- 3.3 Results of tests are documented accurately and in a timely manner to ensure test results remain current
- 3.4 Site and installation records are updated to ensure traceability of system information performance is maintained in accordance with workplace procedures
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| WC726 | UEENEEN104A | Test copper rail signalling cables | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OFD87 | UEERS0037 | Test copper rail signalling cables | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| BFO2 | UEE41220 | Certificate IV in Electrical - Rail Signalling | Qualification |
| BFO5 | UEE33020 | Certificate III in Electrical Fitting | Qualification |
| BFN2 | UEE40620 | Certificate IV in Electrotechnology - Systems Electrician | Qualification |
| BFN0 | UEE30820 | Certificate III in Electrotechnology Electrician | Qualification |