Unit of competency Outline
Date retreived
22/07/2026 6:09 AM AWST
22/07/2026 6:09 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Monitor and operate flow control, pressure measuring and regulating devices for gas transmission
Monitor and operate flow control, pressure measuring and regulating devices for gas transmission
Unit of competency
National Code
UEGNSG356A
UEGNSG356A
State Code
WJ046
WJ046
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
07/04/2014
Field of Education
040327 - Plumbing
Original Release Date
07/04/2014
Nominal Hours
90
Description
1) Scope:1.1) DescriptorThis unit covers monitoring and operating of complex flow control, measuring and regulating devices to monitor and control gas supply in gas transmission systems in accordance with relevant legislation, code, regulations and procedures. It encompasses inspecting, testing and controlling; regulation of flow and pressure; measuring; recording and reporting; regulation of flow and regulation devices; regulation of the system; equipment; organisational and statutory requirements.
Notes
Elements and Performance Criteria
No information
RANGE STATEMENT
9)This relates to the competency standard unit as a whole providing the range of contexts and conditions to which the Performance Criteria apply. It allows for different work environments and situations that will affect performance.
This unit shall be demonstrated in relation to the monitoring and operating of complex flow control, measuring and regulating devices for gas pressure and flow control in transmission systems.
The following constants and variables included in the element/Performance Criteria in this unit are fully described in the Definitions Section of this volume and form an integral part of the Range Statement of this unit:
Inspecting and controlling
Regulation of flow and pressure
Measuring
Recording and reporting
Regulation of flow and regulation devices
Regulation of the system
Equipment
Organisational and statutory requirements
9)This relates to the competency standard unit as a whole providing the range of contexts and conditions to which the Performance Criteria apply. It allows for different work environments and situations that will affect performance.
This unit shall be demonstrated in relation to the monitoring and operating of complex flow control, measuring and regulating devices for gas pressure and flow control in transmission systems.
The following constants and variables included in the element/Performance Criteria in this unit are fully described in the Definitions Section of this volume and form an integral part of the Range Statement of this unit:
Inspecting and controlling
Regulation of flow and pressure
Measuring
Recording and reporting
Regulation of flow and regulation devices
Regulation of the system
Equipment
Organisational and statutory requirements
EVIDENCE GUIDE
8) The Evidence Guide forms an integral part of this Competency Standard Unit and shall be used in conjunction with all components parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.
Overview of Assessment
8.1)
Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the Industry’s preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accord with Industry regulatory policy in this regard.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Hence, sources of evidence need to be ‘rich’ in nature so as to minimise error in judgment.
Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data gathered will contribute to its ‘richness’. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practiced. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.
Critical aspects of evidence required to demonstrate competency in this unit
8.2)
Before the critical aspects of evidence are considered all prerequisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated Performance Criteria shall be demonstrated on at least two occasions in accordance with the ‘Assessment Guidelines — UEG11’. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the Performance Criteria and range
Apply sustainable energy principles and practices as specified in the Performance Criteria and range
Demonstrate an understanding of the required knowledge and skills as described in this unit to such an extent that the learner’s performance outcome is reported in accordance with the preferred approach; namely a percentile graded result, where required by the regulated environment
Demonstrate an appropriate level of employability skills
Conduct work observing the relevant anti-discrimination legislation, regulations, polices and workplace procedures
Demonstrate performance across a representative range of contexts from the prescribed items below.
Monitoring and operating of complex flow control, measuring and regulating devices for gas pressure and flow control in transmission systems in accordance with relevant legislation, code, regulations and procedures as described as described in 9.) Range Statement and including:
Range of tools/equipment/procedures/workplace
Group No
The minimum number of items on which skill is to be demonstrated
Item List
A
At least 3
Interpret technical drawings and symbols
Selection of appropriate tools and equipment
System knowledge of Transmission pipelines and stations
Relevant knowledge of AS3885 Part 3
B
All
Auxiliary control systems knowledge and understanding
Wide open monitor operation
Monitor Active Regulation
Two stage pressure reduction with monitor override
C
All
RTU control of regulators
D
At least 2
Pressure Controllers, operation, maintenance and understanding
Commissioning/Setting
Troubleshooting
Pressure Boosters minor repairs
Knowledge of types/models
E
At least 2
Regulator knowledge and understanding
Sleeve types
Control valves
Pressure reliefs
Diaphragm types
Hydraulic Plug types
F
All
Valve maintenance and operation.
Automatic Line Break Valves operation and maintenance
Configuration of Ball, Plug, Gate, Instrument and Butterfly valves
G
At least 3
Working knowledge of:
Diaphragm meters
Rotary meters
Turbine meters
Ultrasonic meters
Orifice plates
Coriolis meters
Oil changing
H
At least 3
Operational checks
Single run units
Dual run units
City gates or Trunk Receiving Stations (TRS)
District regulators
Pressure Reliefs
I
At least 3
Maintenance Activities
Single run units
Dual run units
City gates
District Regulators
Pressure Reliefs
J
At least 3
Pressure alterations
Industrial units
City gates
Regulator Stations
Distribution mains
K
At least 3
Flaring and Purging
Industrial units
City gates
Regulator Stations
Distribution mains
L
At least 3
Overpressure Protection Systems function and operation.
OPSO
Internal pressure relief systems
Pressure relief valves
Slam Shut systems
Valve Actuator and control systems
M
All
Paperwork:
Risk assessments
Time sheets
Completing work records
Notifications and work permits
Equipment check lists
Meter bypass forms
Service orders
Pressure recording charts
N
At least one occasion
Deal with an unplanned event by drawing on required knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items
Context of and specific resources for assessment
8.3)
This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this Competency Standard Unit.
Appropriate environmental regulation and work practices.
Appropriate organisational requirements.
In addition to the resources listed above, in Context of and specific resources for assessment, evidence should show demonstrated competency in monitoring and operating flow control, pressure, measuring and regulating devices for gas transmission.
Assessment of this competency must also be undertaken in either an actual workplace or under a simulated work environment. Assessment must also integrate the employability skills.
Method of assessment
8.4)
This Competency Standard Unit shall be assessed by methods given in Volume 1, Part 3 ‘Assessment Guidelines’.
Note: Competent performance with inherent safe working practices is expected in the Industry to which this Competency Standard Unit applies. This requires that the specified required l Knowledge and Skills are assessed in a structured environment which is primarily intended for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the required knowledge and skills described in this unit.
Concurrent assessment and relationship with other units
8.5)
There are no recommended concurrent assessments with this unit, however in some cases efficiencies may be gained in terms of learning and assessment effort being concurrently managed with allied Competency Standard Units where listed.
UEGNSG132A
Carry out basic work activities in a gas industry work environment
UEGNSG133A
Comply with environmental policies and procedures in the utilities industry
UEGNSG134A
Establish a utilities infrastructure work site
BSBFLM312B
Contribute to team effectiveness
BSBFLM303C
Contribute to effective workplace relationships
8) The Evidence Guide forms an integral part of this Competency Standard Unit and shall be used in conjunction with all components parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.
Overview of Assessment
8.1)
Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the Industry’s preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accord with Industry regulatory policy in this regard.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Hence, sources of evidence need to be ‘rich’ in nature so as to minimise error in judgment.
Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data gathered will contribute to its ‘richness’. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practiced. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.
Critical aspects of evidence required to demonstrate competency in this unit
8.2)
Before the critical aspects of evidence are considered all prerequisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated Performance Criteria shall be demonstrated on at least two occasions in accordance with the ‘Assessment Guidelines — UEG11’. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the Performance Criteria and range
Apply sustainable energy principles and practices as specified in the Performance Criteria and range
Demonstrate an understanding of the required knowledge and skills as described in this unit to such an extent that the learner’s performance outcome is reported in accordance with the preferred approach; namely a percentile graded result, where required by the regulated environment
Demonstrate an appropriate level of employability skills
Conduct work observing the relevant anti-discrimination legislation, regulations, polices and workplace procedures
Demonstrate performance across a representative range of contexts from the prescribed items below.
Monitoring and operating of complex flow control, measuring and regulating devices for gas pressure and flow control in transmission systems in accordance with relevant legislation, code, regulations and procedures as described as described in 9.) Range Statement and including:
Range of tools/equipment/procedures/workplace
Group No
The minimum number of items on which skill is to be demonstrated
Item List
A
At least 3
Interpret technical drawings and symbols
Selection of appropriate tools and equipment
System knowledge of Transmission pipelines and stations
Relevant knowledge of AS3885 Part 3
B
All
Auxiliary control systems knowledge and understanding
Wide open monitor operation
Monitor Active Regulation
Two stage pressure reduction with monitor override
C
All
RTU control of regulators
D
At least 2
Pressure Controllers, operation, maintenance and understanding
Commissioning/Setting
Troubleshooting
Pressure Boosters minor repairs
Knowledge of types/models
E
At least 2
Regulator knowledge and understanding
Sleeve types
Control valves
Pressure reliefs
Diaphragm types
Hydraulic Plug types
F
All
Valve maintenance and operation.
Automatic Line Break Valves operation and maintenance
Configuration of Ball, Plug, Gate, Instrument and Butterfly valves
G
At least 3
Working knowledge of:
Diaphragm meters
Rotary meters
Turbine meters
Ultrasonic meters
Orifice plates
Coriolis meters
Oil changing
H
At least 3
Operational checks
Single run units
Dual run units
City gates or Trunk Receiving Stations (TRS)
District regulators
Pressure Reliefs
I
At least 3
Maintenance Activities
Single run units
Dual run units
City gates
District Regulators
Pressure Reliefs
J
At least 3
Pressure alterations
Industrial units
City gates
Regulator Stations
Distribution mains
K
At least 3
Flaring and Purging
Industrial units
City gates
Regulator Stations
Distribution mains
L
At least 3
Overpressure Protection Systems function and operation.
OPSO
Internal pressure relief systems
Pressure relief valves
Slam Shut systems
Valve Actuator and control systems
M
All
Paperwork:
Risk assessments
Time sheets
Completing work records
Notifications and work permits
Equipment check lists
Meter bypass forms
Service orders
Pressure recording charts
N
At least one occasion
Deal with an unplanned event by drawing on required knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items
Context of and specific resources for assessment
8.3)
This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this Competency Standard Unit.
Appropriate environmental regulation and work practices.
Appropriate organisational requirements.
In addition to the resources listed above, in Context of and specific resources for assessment, evidence should show demonstrated competency in monitoring and operating flow control, pressure, measuring and regulating devices for gas transmission.
Assessment of this competency must also be undertaken in either an actual workplace or under a simulated work environment. Assessment must also integrate the employability skills.
Method of assessment
8.4)
This Competency Standard Unit shall be assessed by methods given in Volume 1, Part 3 ‘Assessment Guidelines’.
Note: Competent performance with inherent safe working practices is expected in the Industry to which this Competency Standard Unit applies. This requires that the specified required l Knowledge and Skills are assessed in a structured environment which is primarily intended for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the required knowledge and skills described in this unit.
Concurrent assessment and relationship with other units
8.5)
There are no recommended concurrent assessments with this unit, however in some cases efficiencies may be gained in terms of learning and assessment effort being concurrently managed with allied Competency Standard Units where listed.
UEGNSG132A
Carry out basic work activities in a gas industry work environment
UEGNSG133A
Comply with environmental policies and procedures in the utilities industry
UEGNSG134A
Establish a utilities infrastructure work site
BSBFLM312B
Contribute to team effectiveness
BSBFLM303C
Contribute to effective workplace relationships
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| S8185 | UEGNSG318B | Monitor and operate flow control, pressure, measuring and regulating devices for gas transmission | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAD18 | UEGNSG356 | Monitor and operate flow control, pressure measuring and regulating devices for gas transmission | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J837 | UEG60114 | Advanced Diploma of Gas Supply Industry Operations | Qualification |
| J836 | UEG50114 | Diploma of Gas Supply Industry Operations | Qualification |
| J835 | UEG40114 | Certificate IV in Gas Supply Industry Operations | Qualification |
| J834 | UEG30114 | Certificate III in Gas Supply Industry Operations | Qualification |