Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Assess documentation for annual fire systems certification inspections
Assess documentation for annual fire systems certification inspections
Unit of competency
National Code
CPCSFS5015A
CPCSFS5015A
State Code
WA419
WA419
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
20/06/2014
Field of Education
039905 - Fire Technology
Original Release Date
20/06/2014
Nominal Hours
55
Description
This unit of competency specifies the outcomes required to research the applicable regulatory requirements for existing fire systems in all types of buildings, and assess compliance documentation to determine whether requirements are met.Licensing, legislative, regulatory or certification requirements may apply to this unit and so the varying state or territory requirements should be confirmed with the relevant body.
Notes
Elements and Performance Criteria
1. Determine the installation dates for fire systems.
- 1.1. The construction dates and modification histories of buildings to be inspected are accessed, interpreted and noted.
- 1.2. The types of fire systems installed in buildings to be inspected are identified from compliance documentation.
- 1.3. The installation dates for individual fire systems in buildings to be inspected are identified.
2. Research and interpret the applicable codes and standards.
- 2.1. The current and historical legislation, codes and standards applicable to individual fire systems at the time of installation, or modification of the building are researched and identified.
- 2.2. The detailed requirements of applicable historical legislation, codes and standards are researched and interpreted.
- 2.3. Any disparity between historical legislation, codes and standards applicable at the installation or modification date and current fire safety requirements are noted and reported to relevant stakeholders.
- 2.4. Checklists and notes on applicable current and historical codes and standards are prepared to assist the annual inspection process.
3. Assess and report on fire system compliance documentation.
- 3.1. Schedules for the inspection, testing and maintenance of fire safety systems are reviewed and checked for compliance with current regulatory requirements.
- 3.2. Documentation for regular fire systems inspection and testing activities is reviewed and checked for currency and completeness.
- 3.3. Information regarding non-compliance issues and defects is identified and noted.
- 3.4. Documentary evidence of resolution of non-compliance issues and defects is requested and reviewed, if available.
- 3.5. Checklists and notes on non-compliance issues and defects identified from compliance documentation are prepared to assist the annual inspection process.
- 3.6. Reports detailing anomalies and omissions in fire systems' compliance documentation are prepared and processed according to workplace and regulatory requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Fire systems may include:
water-based systems, including:
wet pipe sprinkler systems
deluge and drencher systems
dry pipe sprinkler systems
pre-action sprinkler systems
early suppression fast response (ESFR)
hydrants, hose reels and monitors
water supply tanks
fire pump sets
detection and warning systems, including:
emergency warning and intercommunications systems (EWIS)
fire detection and alarm systems
smoke control systems
emergency lighting systems
special hazard fire systems, including:
foam systems (low expansion, medium expansion and high expansion)
gaseous agent systems (carbon dioxide, inert gas and halocarbon gases)
water spray systems (deluge, medium/high velocity water spray and high speed deluge)
chemical systems, including:
powder
wet chemical.
Compliance documentation may include:
fire safety schedules
inspection and testing logbooks
maintenance, repair and replacement documentation.
Current and historical legislation, codes and standards may include:
current, or earlier versions of:
the Building Code of Australia
relevant Australian standards for fire systems
relevant international standards for fire systems
codes and standards stipulated by the regulatory authority or building insurer
obsolete legislation, regulations, codes and standards.
Relevant stakeholders may include:
owners
agents
occupants
local authority.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Fire systems may include:
water-based systems, including:
wet pipe sprinkler systems
deluge and drencher systems
dry pipe sprinkler systems
pre-action sprinkler systems
early suppression fast response (ESFR)
hydrants, hose reels and monitors
water supply tanks
fire pump sets
detection and warning systems, including:
emergency warning and intercommunications systems (EWIS)
fire detection and alarm systems
smoke control systems
emergency lighting systems
special hazard fire systems, including:
foam systems (low expansion, medium expansion and high expansion)
gaseous agent systems (carbon dioxide, inert gas and halocarbon gases)
water spray systems (deluge, medium/high velocity water spray and high speed deluge)
chemical systems, including:
powder
wet chemical.
Compliance documentation may include:
fire safety schedules
inspection and testing logbooks
maintenance, repair and replacement documentation.
Current and historical legislation, codes and standards may include:
current, or earlier versions of:
the Building Code of Australia
relevant Australian standards for fire systems
relevant international standards for fire systems
codes and standards stipulated by the regulatory authority or building insurer
obsolete legislation, regulations, codes and standards.
Relevant stakeholders may include:
owners
agents
occupants
local authority.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment, provided that the simulated or project-based assessment fully replicates workplace conditions, materials, activities, responsibilities and procedures.
This unit could be assessed as an activity involving the establishment of the legislation, codes and standards that apply to existing fire systems in a range of buildings. The activity should include assessment of the compliance of fire safety schedules and inspection, testing and maintenance documentation.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of the required skills and knowledge specified within this unit.
In particular the person should demonstrate:
a comprehensive understanding of the range of relevant current and historical legislation, codes, standards and regulatory requirements for the certification of existing fire systems
an understanding of the function and operation of the full range of fire systems, including water-based fire systems, detection and warning systems and special hazard fire systems used in a wide variety of types of buildings, including:
low-rise buildings
medium-rise buildings
high-rise buildings (over 25 metres)
buildings over 45 metres in height
the ability to research and identify the applicable current and historical compliance requirements for a range of fire systems installed and modified at different dates, in a variety of types of buildings
the ability to assess fire safety schedules and inspection and testing documentation for currency and completeness
the ability to identify and report on anomalies and omissions in fire safety compliance documentation
the ability to produce checklists and notes regarding issues of particular interest found in fire safety documentation, to assist annual inspection processes.
Context of and specific resources for assessment
Assessment of essential underpinning knowledge may be conducted in an off-site context. It is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
documents, drawings, plans and specifications
copies of codes, standards, legislation and regulatory requirements
access to information and communications technology - hardware and software.
Method of assessment
Assessment must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Guidance information for assessment
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment, provided that the simulated or project-based assessment fully replicates workplace conditions, materials, activities, responsibilities and procedures.
This unit could be assessed as an activity involving the establishment of the legislation, codes and standards that apply to existing fire systems in a range of buildings. The activity should include assessment of the compliance of fire safety schedules and inspection, testing and maintenance documentation.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of the required skills and knowledge specified within this unit.
In particular the person should demonstrate:
a comprehensive understanding of the range of relevant current and historical legislation, codes, standards and regulatory requirements for the certification of existing fire systems
an understanding of the function and operation of the full range of fire systems, including water-based fire systems, detection and warning systems and special hazard fire systems used in a wide variety of types of buildings, including:
low-rise buildings
medium-rise buildings
high-rise buildings (over 25 metres)
buildings over 45 metres in height
the ability to research and identify the applicable current and historical compliance requirements for a range of fire systems installed and modified at different dates, in a variety of types of buildings
the ability to assess fire safety schedules and inspection and testing documentation for currency and completeness
the ability to identify and report on anomalies and omissions in fire safety compliance documentation
the ability to produce checklists and notes regarding issues of particular interest found in fire safety documentation, to assist annual inspection processes.
Context of and specific resources for assessment
Assessment of essential underpinning knowledge may be conducted in an off-site context. It is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
documents, drawings, plans and specifications
copies of codes, standards, legislation and regulatory requirements
access to information and communications technology - hardware and software.
Method of assessment
Assessment must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Guidance information for assessment
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OCM32 | CPCSFS5015 | Prepare documentation for annual fire systems inspections | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| W713 | CPC50509 | Diploma of Fire Systems Design | Qualification |