Unit of competency Outline
Date retreived
22/07/2026 8:40 AM AWST
22/07/2026 8:40 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install LPG, CNG and LNG electrical control equipment
Install LPG, CNG and LNG electrical control equipment
Unit of competency
National Code
AURTTL3010
AURTTL3010
State Code
WF431
WF431
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
07/08/2013
Field of Education
030505 - Automotive Electrics And Electronics
Original Release Date
07/08/2013
Nominal Hours
30
Description
This unit describes the performance outcomes required to install Liquefied Petroleum Gas (LPG), Compressed Natural Gas (CNG) and Liquefied Natural Gas (LNG) electrical control equipment. It involves identification and confirmation of work requirement, preparation for work, installation of LPG, CNG and LNG electrical control equipment, testing of installed equipment and completion of work finalisation processes, including clean-up and documentation.Licencing, legislative, regulatory or certification requirements may apply to this unit in some jurisdictions. Users are advised to check with the relevant regulatory authority.
Notes
Elements and Performance Criteria
1. Prepare to install electrical control equipment
- 1.1. Workplace instructions are used to determine job requirements
- 1.2. Workplace health and safety (WHS) requirements relating to LPG, CNG and LNG fuel systems are observed and applied throughout the work
- 1.3. Procedures and information are sourced and interpreted
- 1.4. Method options are analysed and those most appropriate to the circumstances are selected
- 1.5. Appropriate tools and equipment are selected and prepared
2. Carry out installation
- 2.1. Installation is performed according to workplace procedures and manufacturer and component supplier specifications and without causing damage to components or systems
- 2.2. Adjustments are made according to workplace procedures and manufacturer and component supplier specifications
3. Conduct post-installation tests and analyse results
- 3.1. Testing is carried out according to workplace procedures and manufacturer and component supplier specifications
- 3.2. Test results are compared with manufacturer and component supplier specifications to indicate compliance or non-compliance
- 3.3. Results are documented according to workplace procedures, including recommendations for necessary repairs or adjustments
4. Clean up work area and finalise work processes
- 4.1. Final inspection is made to ensure work is to workplace expectations and vehicle is presented ready for use
- 4.2. Tools and equipment are checked and stored according to workplace expectations
- 4.3. Workplace and installation documentation is processed according to workplace procedures
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Workplace instructions may include:
computer-generated instructions
verbal instructions
written instructions.
Job requirements may include:
LPG, CNG and LNG fuel system electrical control equipment installation methods, processes and equipment
Workplace health and safety (WHS) requirements:
are those prescribed under legislation, regulations, codes of practice, and workplace policies and procedures
may include:
protective clothing and equipment
use of tools and equipment
handling of material
use of fire-fighting equipment
first aid equipment
hazard control, including control of hazardous materials and toxic substances.
Procedures and information may include:
verbal, written and graphical instructions
signage
work schedules, plans and specifications
work bulletins or memos
material safety data sheets (MSDS)
diagrams or sketches
safe work procedures relating to the installation of LPG, CNG and LNG fuel system electrical control equipment
regulatory and legislative requirements relating to the automotive industry
Australian Design Rules
Engineer’s design specifications and instructions
organisational work specifications and requirements
instructions issued by authorised workplace or external persons
Australian standards
vehicle service requirements and repair manuals.
Adjustments may include:
integrating the electrical control system into the existing wiring loom
changes to the wiring loom length and configuration
changes to the fuel system configuration
changes to the air intake system configuration.
Tests may include:
testing for electrical continuity, resistance, shorts to ground, voltage drop
verifying correct operation of associated vehicle systems
gas leakage checks.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Workplace instructions may include:
computer-generated instructions
verbal instructions
written instructions.
Job requirements may include:
LPG, CNG and LNG fuel system electrical control equipment installation methods, processes and equipment
Workplace health and safety (WHS) requirements:
are those prescribed under legislation, regulations, codes of practice, and workplace policies and procedures
may include:
protective clothing and equipment
use of tools and equipment
handling of material
use of fire-fighting equipment
first aid equipment
hazard control, including control of hazardous materials and toxic substances.
Procedures and information may include:
verbal, written and graphical instructions
signage
work schedules, plans and specifications
work bulletins or memos
material safety data sheets (MSDS)
diagrams or sketches
safe work procedures relating to the installation of LPG, CNG and LNG fuel system electrical control equipment
regulatory and legislative requirements relating to the automotive industry
Australian Design Rules
Engineer’s design specifications and instructions
organisational work specifications and requirements
instructions issued by authorised workplace or external persons
Australian standards
vehicle service requirements and repair manuals.
Adjustments may include:
integrating the electrical control system into the existing wiring loom
changes to the wiring loom length and configuration
changes to the fuel system configuration
changes to the air intake system configuration.
Tests may include:
testing for electrical continuity, resistance, shorts to ground, voltage drop
verifying correct operation of associated vehicle systems
gas leakage checks.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy all of the requirements of the performance criteria and required skills and knowledge.
A person who demonstrates competency in this unit must be able to:
observe safety procedures and requirements
select methods and techniques appropriate to the circumstances
conduct the installation and testing of a range of LPG, CNG or LNG electrical control equipment according to workplace, manufacturer and component supplier requirements
interpret and record test results
present vehicle in a condition that complies with workplace requirements.
Context of, and specific resources for assessment
Competency is to be assessed in the workplace or a simulated workplace environment that accurately reflects performance in a real workplace setting.
Assessment is to occur:
using standard workplace practices and procedures
following safety requirements
applying environmental constraints.
Assessment is to comply with relevant:
regulatory requirements
Australian standards
industry codes of practice.
The following resources must be made available for the assessment of this unit:
workplace location or simulated workplace
vehicles that require the fitment of gas system electrical control equipment
material relevant to installing gas system electrical control equipment
equipment, hand and power tools appropriate to installing gas system electrical control equipment
specifications and workplace instructions.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of this Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with the application of required skills and knowledge.
Assessment methods must be by direct observation of tasks and include questioning on required skills and knowledge to ensure correct interpretation and application.
Competence in this unit may be assessed in conjunction with other units which together form part of a holistic work role.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate the needs of diverse clients.
Assessment processes and techniques must be culturally sensitive and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
The evidence required to demonstrate competency in this unit must be relevant to workplace operations and satisfy all of the requirements of the performance criteria and required skills and knowledge.
A person who demonstrates competency in this unit must be able to:
observe safety procedures and requirements
select methods and techniques appropriate to the circumstances
conduct the installation and testing of a range of LPG, CNG or LNG electrical control equipment according to workplace, manufacturer and component supplier requirements
interpret and record test results
present vehicle in a condition that complies with workplace requirements.
Context of, and specific resources for assessment
Competency is to be assessed in the workplace or a simulated workplace environment that accurately reflects performance in a real workplace setting.
Assessment is to occur:
using standard workplace practices and procedures
following safety requirements
applying environmental constraints.
Assessment is to comply with relevant:
regulatory requirements
Australian standards
industry codes of practice.
The following resources must be made available for the assessment of this unit:
workplace location or simulated workplace
vehicles that require the fitment of gas system electrical control equipment
material relevant to installing gas system electrical control equipment
equipment, hand and power tools appropriate to installing gas system electrical control equipment
specifications and workplace instructions.
Method of assessment
Assessment must satisfy the endorsed Assessment Guidelines of this Training Package.
Assessment methods must confirm consistency and accuracy of performance (over time and in a range of workplace relevant contexts) together with the application of required skills and knowledge.
Assessment methods must be by direct observation of tasks and include questioning on required skills and knowledge to ensure correct interpretation and application.
Competence in this unit may be assessed in conjunction with other units which together form part of a holistic work role.
Where applicable, reasonable adjustment must be made to work environments and training situations to accommodate the needs of diverse clients.
Assessment processes and techniques must be culturally sensitive and appropriate to the language, literacy and numeracy capacity of the candidate and the work being performed.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W5039 | AURT304031A | Install LPG/CNG electrical control equipment | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AXA56 | AURTTL010 | Install LPG, CNG and LNG electrical control equipment | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J408 | AUR32012 | Certificate III in Automotive Alternative Fuel Technology | Qualification |
| J419 | AUR40612 | Certificate IV in Automotive Electrical Technology | Qualification |
| J391 | AUR30312 | Certificate III in Automotive Electrical Technology | Qualification |