Unit of competency Outline

Date retreived
22/07/2026 5:52 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Select refrigerant piping, accessories and associated controls

Select refrigerant piping, accessories and associated controls

Unit of competency
National Code
UEERA0081
State Code
OBX39
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031315 - Refrigeration And Air Conditioning Mechanics
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to select refrigerant piping, accessories and associated controls.It includes selecting refrigerant piping, accessories and controls for refrigeration and air conditioning installation to comply with regulations, industry standards and specifications. It also includes developing refrigerant pipe work arrangements; selecting pipe work and fittings, refrigerant flow controls and accessories, and mechanical and electrical control devices based on specifications, industry standards and manufacturer catalogues to determine calculated and deemed-to-comply solutions and documenting selection information.The skills and knowledge described in this unit may, in some jurisdictions, require a licence or permit to practice in the workplace subject to regulations for undertaking refrigeration and air conditioning work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.
Notes
Elements and Performance Criteria
1 Prepare to selectrefrigerant piping, accessories and associated controls
  • 1.1 Extent and nature of the refrigeration installation is determined from job specifications
  • 1.2 WHS/OHS and regulatory requirements of the refrigeration system are identified, obtained and applied
2 Develop refrigerant pipe work arrangements
  • 2.1 Intended location of refrigeration equipment is determined from job specifications and site drawings or deemed-to-comply arrangements
  • 2.2 Pipe work arrangements are developed to ensure safe and functional operation of the refrigerant system in accordance with workplace procedures
  • 2.3 Pipe work is arranged to comply with technical industry standards, job specifications and requirements
3 Select refrigerant piping, accessories and associated controls
  • 3.1 Suitable pipe and tubing are selected for the environment in which it is to be installed in accordance with industry standards
  • 3.2 Pipe and tubing are sized to meet refrigeration parameters and capacity requirements for the refrigerant to be used
  • 3.3 Pipe and tubing quantities are determined from equipment location diagrams and job specifications
  • 3.4 Refrigeration controls and accessories are selected to meet load requirements based on calculated or deemed-to-comply solutions
  • 3.5 Control devices are selected to meet functional and regulatory requirements
  • 3.6 Electrical control devices are selected to meet current voltage and ingress protection ratings in accordance with industry standards
  • 3.7 Evidence is obtained to confirm the selected refrigeration equipment and control devices comply with job requirements and industry standards
4 Document refrigerant piping, accessories and associated controls selection
  • 4.1 Refrigerant piping, accessories and associated control selections, including calculations, are documented in accordance with workplace procedures
  • 4.2 Refrigeration installation arrangement and specifications for selected items are documented in accordance with workplace procedures and forwarded to appropriate person/s
No information
No information
Replaces
State Code National Code Title Type
S7346 UEENEEJ110A Select refrigerant piping, accessories and associated controls Unit of competency
State Code National Code Title Type
BMB7 UEE32225 Certificate III in Air Conditioning and Refrigeration Qualification
BFJ5 UEE32220 Certificate III in Air Conditioning and Refrigeration Qualification
BFQ1 UEE62520 Advanced Diploma of Air Conditioning and Refrigeration Engineering Qualification
BFK7 UEE51220 Diploma of Air Conditioning and Refrigeration Engineering Qualification
BMB0 UEE51225 Diploma of Air Conditioning and Refrigeration Engineering Qualification
BMB1 UEE62525 Advanced Diploma of Air Conditioning and Refrigeration Engineering Qualification
BFP9 UEE42720 Certificate IV in Air Conditioning and Refrigeration Servicing Qualification
BMB5 UEE42725 Certificate IV in Air Conditioning and Refrigeration Servicing Qualification
BMB9 UEE42825 Certificate IV in Air-conditioning Systems Energy Management and Control Qualification
BFL0 UEE42820 Certificate IV in Air-conditioning Systems Energy Management and Control Qualification
BFO0 UEE50320 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BMB4 UEE50325 Diploma of Electrical and Refrigeration and Air Conditioning Qualification
BFO9 UEE62420 Advanced Diploma of Engineering Technology - Air Conditioning and Refrigeration Qualification
BFP3 UEE51120 Diploma of Engineering Technology - Refrigeration and Air Conditioning Qualification
BFN6 UEE42920 Certificate IV in Refrigeration and Air Conditioning Systems Qualification
BMB6 UEE42925 Certificate IV in Refrigeration and Air Conditioning Systems Qualification