Unit of competency Outline

Date retreived
22/07/2026 5:30 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Place and connect electrical coils

Place and connect electrical coils

Unit of competency
National Code
UEEEL0056
State Code
OBZ62
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
36
Description
This unit involves the skills and knowledge required to insulate, place and connect electrical coils in small armature/stators, transformers and solenoid equipped devices.It includes working safely, using tools, placing and connecting conductors, following technical instructions and workplace procedures, and completing work reports.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to place and connect electrical coils
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
  • 1.2 Existing WHS/OHS risk control measures for work preparation are followed
  • 1.3 Work instructions are identified, obtained and applied
  • 1.4 Advice is sought from the work supervisor to ensure the work is coordinated effectively with others
  • 1.5 Materials required for the work are obtained in accordance with workplace routines and procedures
  • 1.6 Tools, equipment and testing devices needed to carry out work are obtained and checked for correct operation and safety
2 Place and connect electrical coil
  • 2.1 Existing WHS/OHS risk control work measures are followed
  • 2.2 Machines/equipment are checked and isolated in accordance with WHS/OHS requirements and workplace procedures
  • 2.3 Coils and insulation are selected in accordance with work instructions and workplace procedures
  • 2.4 Insulation is cut and applied in accordance with work instructions and workplace procedures
  • 2.5 Coils are placed in accordance with work instructions and workplace procedures
  • 2.6 Coil ends are prepared and connections made in accordance with work instructions and workplace procedures
  • 2.7 Unplanned situations are responded to in accordance with workplace procedures in a manner that minimises risk to personnel and equipment
  • 2.8 Routine quality checks are conducted to ensure electrical coils are correctly placed and connected in accordance with work instructions
  • 2.9 Electrical coil work is completed within timeframe, environment and workplace conditions
3 Complete workplace report
  • 3.1 WHS/OHS work completion risk control measures are followed
  • 3.2 Workplace report, forms/data sheets are completed accurately in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WC495 UEENEEG151A Place and connect electrical coils Unit of competency