Unit of competency Outline
Date retreived
23/07/2026 12:59 AM AWST
23/07/2026 12:59 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Operate Ammonia Refrigeration Plant
Operate Ammonia Refrigeration Plant
Unit of competency
National Code
UEENEEJ196A
UEENEEJ196A
State Code
S7426
S7426
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
07/11/2011
Field of Education
030717 - Plant And Machine Operations
Original Release Date
07/11/2011
Nominal Hours
36
Description
1) 1.1) DescriptorThis unit covers specialised procedures for operating an industrial refrigeration plant using ammonia as the refrigerant. It encompasses applying specialised knowledge of refrigeration principles that apply to ammonia, specifying the normal operating parameters for the plant, rectifying faults and defective components within organisational guidelines and completing the necessary service documentation.
Notes
Elements and Performance Criteria
1 Prepare to operate Ammonia refrigerant plant
- 1.1 OHS procedures for a given work area are identified, obtained and understood through established routines and procedures.
- 1.2 Refrigeration systems and components on which the work is to be carried out are identified.
- 1.3 Established OHS risk control measures and procedures are followed in preparation for the work.
- 1.4 Safety hazards which have not previously been identified are reported and advice on risk control measures is sought from the work supervisor.
- 1.5 The nature of work is obtained from documentation or from work supervisor to establish the scope of work to be undertaken.
- 1.6 Advice is sought from the work supervisor to ensure the work is coordinated effectively with others.
- 1.7 Sources of materials that may be required for the work are accessed in accordance with established routines and procedures.
- 1.8 Tools, equipment and testing devices needed to carry out the work are obtained and checked for correct operation and safety
- 1.9 The refrigeration system's required operating conditions are established from documentation/supervisor and the application of refrigeration fundamentals
2 Operate Ammonia refrigeration plant
- 2.1 Established OHS risk control measures and procedures for carrying out the work are followed.
- 2.2 Refrigeration plant is started up in accordance with established procedures, standard, codes and regulations
- 2.3 Measuring refrigeration system operating parameters is conducted in strict accordance with OHS requirements and established safety procedures
- 2.4 Supervisor or person in charge is advised of system and components performing outside their operating parameters to facilitate remedial action.
- 2.5 Remedial action is implemented within the organisation's procedures.
- 2.6 Service procedures are completed according to identified organisational procedures according to SOPs.
- 2.7 Daily processing requirements are ascertained to predict demand on refrigeration plant.
- 2.8 Oral and written information on the performance of the plant is exchanged formally and informally between the operator and supervisor/production team.
- 2.9 Equipment controls are adjusted to prepare plant to meet the load.
- 2.10 Action is taken in a proactive way to maintain the performance of the plant.
- 2.11 Demands on plant consumables are calculated to facilitate the ordering of replacements.
- 2.12 Strategies are developed to meet demand in the event of equipment malfunction or breakdown.
3 Complete work and report on operating Ammonia refrigeration plant
- 3.1 OHS work completion risk control measures and procedures are followed.
- 3.2 Work site is cleaned and made safe in accordance with established procedures.
- 3.3 Plant performance records are maintained and distributed to meet organisational standards.
RANGE STATEMENT
8) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance.
This unit must be demonstrated in relation to Ammonia refrigeration systems and include starting up, determining operating conditions using measurement and basic calculation methods, basic repairs and shutting down the system. These conditions include suction, inter-stage and discharge pressures, ambient, evaporator, inter-stage and condensing temperatures, evaporator, and condenser temperature difference.
Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1.
8) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance.
This unit must be demonstrated in relation to Ammonia refrigeration systems and include starting up, determining operating conditions using measurement and basic calculation methods, basic repairs and shutting down the system. These conditions include suction, inter-stage and discharge pressures, ambient, evaporator, inter-stage and condensing temperatures, evaporator, and condenser temperature difference.
Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1.
EVIDENCE GUIDE
9) The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package.
The Evidence Guide forms an integral part of this unit. It must be used in conjunction with all parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.
Overview of Assessment
9.1)
Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the industry-preferred model for apprenticeships.
However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. In some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accordance with industry and regulatory policy.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be 'rich' in nature to minimise error in judgment.
Activities associated with normal everyday work influence decisions about how/how much the data gathered will contribute to its 'richness'. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.
Critical aspects of evidence required to demonstrate competency in this unit
9.2)
Before the critical aspects of evidence are considered all prerequisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated performance criteria shall be demonstrated on at least two occasions in accordance with the 'Assessment Guidelines - UEE07'. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the performance criteria and range statement
Apply sustainable energy principles and practices as specified in the performance criteria and range statement
Demonstrate an understanding of the essential knowledge and associated skills as described in this unit to such an extent that the learner's performance outcome is reported in accordance with the preferred approach; namely a percentile graded result, where required by the regulated environment
Demonstrate an appropriate level of skills enabling employment
Conduct work observing the relevant Anti Discrimination legislation, regulations, polices and workplace procedures
Demonstrated consistent performance across a representative range of contexts from the prescribed items below:
Operating an industrial refrigeration plant using ammonia as the refrigerant, determining plant operating conditions, rectifying faults and defective components within organisational guidelines and completing the necessary service documentation.
A Starting up Ammonia refrigerant plant
B.Selecting and using appropriate measuring devices correctly
C Recording measurements
D Using calculation methods accurately
E Identifying the conditions of the refrigerant (R717) at various locations in the vapour compression and liquid recirculation system.
F Taking remedial action within organisational procedures and job role
G Documenting operating conditions correctly
H. Conducting servicing procedures according to the schedule, including the inspection of all lagging, insulation, pipe and duct mountings
I. Shutting down Ammonia refrigerant plant
J. Dealing with unplanned events by drawing on essential knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items
Context of and specific resources for assessment
9.3)
This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this unit.
These should be part of the formal learning/assessment environment.
Note:
Where simulation is considered a suitable strategy for assessment, conditions must be authentic and as far as possible reproduce and replicate the workplace and be consistent with the approved industry simulation policy.
Evidence should show demonstrated competency in operating and servicing ammonia refrigeration plant in a safe manner following organisational procedures.
Method of assessment
9.4)
This unit shall be assessed by methods given in Volume 1, Part 3 'Assessment Guidelines'.
Note: Competent performance with inherent safe working practices is expected in the Industry to which this unit applies. This requires assessment in a structured environment which is intended primarily for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the essential knowledge and skills described in this unit.
Concurrent assessment and relationship with other units
9.5)
For optimisation of training and assessment effort, competency development in this unit may be arranged concurrently with unit:
UEENEEJ178A Apply safety awareness and legal requirements for ammonia refrigerant
9) The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package.
The Evidence Guide forms an integral part of this unit. It must be used in conjunction with all parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.
Overview of Assessment
9.1)
Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the industry-preferred model for apprenticeships.
However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. In some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accordance with industry and regulatory policy.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be 'rich' in nature to minimise error in judgment.
Activities associated with normal everyday work influence decisions about how/how much the data gathered will contribute to its 'richness'. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.
Critical aspects of evidence required to demonstrate competency in this unit
9.2)
Before the critical aspects of evidence are considered all prerequisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated performance criteria shall be demonstrated on at least two occasions in accordance with the 'Assessment Guidelines - UEE07'. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the performance criteria and range statement
Apply sustainable energy principles and practices as specified in the performance criteria and range statement
Demonstrate an understanding of the essential knowledge and associated skills as described in this unit to such an extent that the learner's performance outcome is reported in accordance with the preferred approach; namely a percentile graded result, where required by the regulated environment
Demonstrate an appropriate level of skills enabling employment
Conduct work observing the relevant Anti Discrimination legislation, regulations, polices and workplace procedures
Demonstrated consistent performance across a representative range of contexts from the prescribed items below:
Operating an industrial refrigeration plant using ammonia as the refrigerant, determining plant operating conditions, rectifying faults and defective components within organisational guidelines and completing the necessary service documentation.
A Starting up Ammonia refrigerant plant
B.Selecting and using appropriate measuring devices correctly
C Recording measurements
D Using calculation methods accurately
E Identifying the conditions of the refrigerant (R717) at various locations in the vapour compression and liquid recirculation system.
F Taking remedial action within organisational procedures and job role
G Documenting operating conditions correctly
H. Conducting servicing procedures according to the schedule, including the inspection of all lagging, insulation, pipe and duct mountings
I. Shutting down Ammonia refrigerant plant
J. Dealing with unplanned events by drawing on essential knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items
Context of and specific resources for assessment
9.3)
This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this unit.
These should be part of the formal learning/assessment environment.
Note:
Where simulation is considered a suitable strategy for assessment, conditions must be authentic and as far as possible reproduce and replicate the workplace and be consistent with the approved industry simulation policy.
Evidence should show demonstrated competency in operating and servicing ammonia refrigeration plant in a safe manner following organisational procedures.
Method of assessment
9.4)
This unit shall be assessed by methods given in Volume 1, Part 3 'Assessment Guidelines'.
Note: Competent performance with inherent safe working practices is expected in the Industry to which this unit applies. This requires assessment in a structured environment which is intended primarily for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the essential knowledge and skills described in this unit.
Concurrent assessment and relationship with other units
9.5)
For optimisation of training and assessment effort, competency development in this unit may be arranged concurrently with unit:
UEENEEJ178A Apply safety awareness and legal requirements for ammonia refrigerant
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OBZ12 | UEERA0057 | Operate ammonia refrigeration plant | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| AB660 | UEESS00085 | Refrigeration-Air Conditioning - Operate Ammonia Refrigeration Plant | Skill set |