Unit of competency Outline

Date retreived
23/07/2026 2:32 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Dispose of explosive ordnance

Dispose of explosive ordnance

Unit of competency
National Code
DEFEO701C
State Code
AVS85
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
24/01/2013
State Implementation and Classification
Approved Date
Field of Education
039999 - Engineering And Related Technologies, N.e.c.
Original Release Date
Nominal Hours
0
Description
This unit covers the competency required to prepare a destruction site and to dispose of explosive ordnance by burning, detonation or by functioning on a licensed demolition range under controlled conditions.This unit specifically precludes the destruction of unexploded ordnance whether that has malfunctioned/failed to function or been otherwise compromised while being handled/mishandled for storage, maintenance or transportation. The unit that covers the competency relating to destruction of unexploded ordnance is DEFEO702D Destroy unexploded ordnance.
Notes
Elements and Performance Criteria
1. Prepare for destruction
  • 1.1 Requirement for disposal of explosive ordnance is identified from work requests/instructions and confirmed with relevant personnel.
  • 1.2 Work health and safety (WHS) requirements including those contained in organisational procedures, are applied throughout the operation.
  • 1.3 Item(s) of explosive ordnance to be disposed of and disposal method are confirmed in accordance with organisation policy and procedures.
  • 1.4 Documentation and instructions are prepared in accordance with statutory and organisation requirements.
  • 1.5 Liaison and notification of parties affected by the disposal is undertaken in accordance with organisation policy and procedures, and Range Standing Orders.
  • 1.6 Site/equipment preparation is completed in accordance with organisation policy and procedures, and Range Standing Orders.
  • 1.7 Net explosive quantities and compatibility are identified, calculated, analysed and applied throughout the operation.
2. Dispose of explosive ordnance
  • 2.1 Explosive ordnance and disposal means are prepared and tested in accordance with Range Standing Orders and organisation policy.
  • 2.2 Explosive ordnance is disposed of using the most appropriate disposal means.
  • 2.3 Emergency and contingency procedures are applied in accordance with organisation policy and Range Standing Orders.
  • 2.4 Residue is inspected to ensure all items have been disposed of in accordance with Range Standing Orders.
3. Finalise the disposal process
  • 3.1 Site/equipment is maintained and/or refurbished in accordance with organisation policy and procedures, and Range Standing Orders.
  • 3.2 Documentation and records are maintained in accordance with statutory, organisation requirements and Range Standing Orders.
The Range Statement relates to the Unit of Competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording in the Performance Criteria is detailed below.
Explosive ordnance includes:
all munitions containing explosives, nuclear fission or fusion materials and biological and chemical agents such as bombs and warheads; guided and ballistic missiles; artillery, mortar, rocket and small arms ammunition; all mines, torpedoes and depth charges; demolition charges; pyrotechnics; clusters and dispensers; cartridge and propellant actuated devices; electro explosive devices; clandestine and other improvised explosive devices; and all similar or related items or components explosive in nature
explosive ordnance in this competency does not include that which has malfunctioned/failed to function following attempted firing or ignition this being classed as unexploded ordnance and the subject of a different competency
Organisation may include:
defence organisation
enterprises that work with explosive ordnance
other government departments or instrumentalities that work with explosive ordnance
Documentation and instructions may include:
range instructions
risk analysis
Preparation may include:
calculation of safety distances including safety fuse burning times
confirmation that the demolition range is licensed for the explosive ordnance calibre, nature and quantity that is being disposed
tests including:
safety fuse
continuity tests on electric detonators
discontinuity tests on firing cables
continuity tests on firing cables
resistance tests on firing cables
Disposal means may be:
by burning in:
an ammunition pit
a furnace
a prepared open site
destruction/jettison at sea in accordance with current instructions
ignition by electric or nonelectric means
The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessment must confirm the ability to:
comply with operational safety including the risk analysis
prepare and refurbish the disposal site or equipment
prepare instructions and documentation
apply net explosive quantity and compatibility limitations
dispose of the explosive ordnance
apply emergency and contingency procedures
Competency must also be demonstrated in a safe and efficient manner with minimal harmful effect on the surrounding environment.
Consistency in performance
Competency should be demonstrated in a range of actual or simulated explosive ordnance disposal contexts.
Context of and specific resources for assessment
Context of assessment
Competency should be assessed in the workplace or in a simulated work environment, in accordance with all relevant legislation and Defence requirements.
Specific resources for assessment
Access is required to:
licensed range
explosive ordnance to be disposed.
Method of assessment
This unit may be assessed with the following unit:
DEFEO101D Work safely with explosive ordnance.
In a public safety environment assessment is usually conducted via direct observation in a training environment or in the workplace via subject matter supervision and/or mentoring, which is typically recorded in a competency workbook.
Assessment is completed using appropriately qualified assessors who select the most appropriate method of assessment.
Assessment may occur in an operational environment or in an industry-approved simulated work environment. Forms of assessment that are typically used include:
direct observation
interviewing the candidate
journals and workplace documentation
third party reports from supervisors
written or oral questions
Replaced By
State Code National Code Title Type
AVR85 DEFEXO101 Dispose of explosives Unit of competency
No information