Qualification Outline
22/07/2026 9:37 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Certificate II in Fire Alarms Servicing
Certificate II in Fire Alarms Servicing
UEE21020
BFJ1
Current
Approved
National Endorsed, State Implementation and Classification
Releases
| Release Version | Release Date | TGA Status | DTWD Status |
|---|---|---|---|
| 3.00 | 20/12/2022 | Current | Approved |
| 2.00 | 23/03/2022 | Replaced | Approved |
| 1.00 | 05/10/2020 | Replaced | Approved |
Description
This qualification covers competencies to select, assemble, set up and test base level fire protection systems in domestic and commercial premises.
No licensing, legislative or certification requirements apply to this qualification at the time of publication.
Schedule
Packaging Rules
A total of 360 weighting points comprising:- 220 core weighting points listed below; plus
- 140 general elective weighting points from the general elective units listed below.
Choose a total of 140 weighting points elective units from the list below, of which between 0 and 60 weighting points can be taken from Group A; and between 80 and 140 weighting points must be taken from Group B; or all 140 weighting points canbe taken from Group B.
Up to 60 weighting points of the general elective units Group A, may be selected, with appropriate contextualisation, from any relevant nationally endorsed Training Package or accredited course, provided selected units contribute to the vocational outcome of the qualification. Previously assigned weighting points are listed in the UEE Electrotechnology Training Package Companion Volume Implementation Guide (CVIG), if not listed weighting points will be 10 points, unless directed from the Electrotechnology Industry Reference Committee (IRC).
There are units of competency within this qualification that contain pre-requisites. Units of competency that have a pre-requisite requirement are identified by this symbol * on training.gov.au. Refer directly to the units of competency to identify pre-requisite requirements to ensure all are complied with. A list of all pre-requisites is also provided in the UEE Pre-requisite Companion Volume.
Where imported units are selected, care must be taken to ensure all pre-requisite units specified are complied with.
1. Core Units
All core units must be completed.
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| OBY70 | UEERE0001 | Apply environmentally and sustainable procedures in the energy sector | 18 | Unit of competency |
| OCA55 | UEECD0007 | Apply work health and safety regulations, codes and practices in the workplace | 18 | Unit of competency |
| OCC08 | UEECD0016 | Document and apply measures to control WHS risks associated with electrotechnology work | 18 | Unit of competency |
| OBX42 | UEECD0019 | Fabricate, assemble and dismantle utilities industry components | 36 | Unit of competency |
| OBY81 | UEECD0020 | Fix and secure electrotechnology equipment | 18 | Unit of competency |
| OCB83 | UEEEC0041 | Install fire detection and warning system apparatus | 36 | Unit of competency |
| OCB19 | UEECD0027 | Participate in development and follow a personal competency development plan | 18 | Unit of competency |
| OCC28 | UEECD0051 | Use drawings, diagrams, schedules, standards, codes and specifications | 36 | Unit of competency |
2. Group A: Imported and Common Elective Units
Between 0 and 60 weighting points may be chosen from Group A.
Please refer to the packaging rules for the full details of available options.
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| OCD34 | BSBOPS203 | Deliver a service to customers | 40 | Unit of competency |
| OBY02 | UEECO0002 | Maintain documentation | 18 | Unit of competency |
| ODX74 | CPCWHS1001 | Prepare to work safely in the construction industry | 6 | Unit of competency |
| OCA56 | UEECD0035 | Provide basic instruction in the use of electrotechnology apparatus | 18 | Unit of competency |
| OCD26 | HLTAID009 | Provide cardiopulmonary resuscitation | 4 | Unit of competency |
| OCC19 | UEECO0016 | Receive and store materials and equipment for electrotechnology work | 18 | Unit of competency |
| OBY79 | UEECO0017 | Source and purchase material/parts for installation or service jobs | 18 | Unit of competency |
3. Group B: Qualification Elective Units
Between 80 and 140 weighting points must be chosen from Group B; or all 140 weighting points can be taken from Group B
Please refer to the packaging rules for the full details of available options.
| State Code | National Code | Title | Hours | Type |
|---|---|---|---|---|
| OBZ75 | UEEIC0002 | Assemble, enter and verify operating instructions in microprocessor equipped devices | 18 | Unit of competency |
| OCC05 | UEEDV0003 | Install and connect cabling for direct access to telecommunications service | 18 | Unit of competency |
| OCB14 | UEECD0025 | Lay wiring/cabling and terminate accessories for extra-low voltage (ELV) circuits | 36 | Unit of competency |
| OBU39 | ICTICT214 | Operate application software packages | 60 | Unit of competency |
| OCA64 | UEECD0043 | Solve problems in direct current circuits | 72 | Unit of competency |
| OBZ39 | UEEEC0076 | Verify compliance and functionality of fire protection system installations | 54 | Unit of competency |
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| A107 | UEE21011 | Certificate II in Fire Alarms Servicing | Qualification |
No information
Entry Requirements
There are no entry requirements for this qualification
Traineeships and Apprenticeships
Part-time is defined as a minimum of 20 hours per week.