Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate H.V. condition changing apparatus

Operate H.V. condition changing apparatus

Unit of competency
National Code
UEPOPS351
State Code
OAG80
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
31/10/2018
State Implementation and Classification
Approved Date
15/05/2019
Field of Education
031301 - Electrical Engineering
Original Release Date
15/05/2019
Nominal Hours
54
Description
This unit involves the skills and knowledge required to undertake the operation of all High Voltage (H.V.) condition changing apparatus.H.V. condition changing apparatus can include on and off load transformer tap changers, capacitor banks, rotary converters, voltage regulators, reactors, current limiters, rectifiers and transformers. H.V. changing apparatus works within system parameters such as voltage, current, frequency, volt ampere reactive load and equipment capability. Competency in this unit requires the ability to plan and prepare work, operate H.V. condition change apparatus and report on H.V. condition during operation. Individuals will, in general, work under supervision, in a power generation facility as an operator.Power generation plant operators are typically trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.Note: Workplace practiceThe application of the skills and knowledge described in this unit may require a licence or training permit to practice in the workplace where work is carried out on gas and electrical installations. Additional conditions may apply under state and territory legislative and regulatory licensing requirements.
Notes
Elements and Performance Criteria
1 Prepareto operate H.V. condition changing apparatus
  • 1.1 Safety requirements for operating High Voltage (H.V.) condition changing apparatus are adhered to, in accordance with Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations, legislative requirements, industry standards, manufacturers' specifications and workplace procedures
  • 1.2 Location of H.V. condition changing apparatus is determined from plans, drawings, system diagrams and maps, in accordance with workplace procedures
  • 1.3 H.V. condition changing apparatus to be operated, is identified and confirmed, with relevant personnel, in accordance with workplace procedures
  • 1.4 Condition and status of H.V. condition changing apparatus is determined visually, in accordance with workplace procedures
  • 1.5 H.V. condition changing apparatus is prepared for operation, in accordance with workplace procedures
2 Conduct H.V. condition changing apparatus operation
  • 2.1 Relevant personnel are advised of progress during H.V. condition changing apparatus operation, in accordance with workplace procedures
  • 2.2 Conditions are evaluated prior to H.V. changing apparatus operation, in accordance with workplace procedures
  • 2.3 H.V. condition changing apparatus is operated in accordance with workplace procedures and manufacturers' recommendations
  • 2.4 H.V. condition changing apparatus is controlled and adjusted to achieve desired outcomes, in accordance with workplace procedures
  • 2.5 H.V. condition changing apparatus is examined, in accordance with workplace procedures, to ensure it has functioned correctly
  • 2.6 Conditions are re-evaluated to confirm correct H.V. condition changing apparatus outcome, in accordance with workplace procedures
  • 2.7 H.V. condition changing apparatus is secured, in accordance with workplace procedures
  • 2.8 Status of H.V. condition changing apparatus is confirmed, in accordance with workplace procedures
3 Complete documentation
  • 3.1 Equipment problems, movements, and status are reported, in accordance with workplace procedures
  • 3.2 Documentation is updated, in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WE371 UEPOPS351B Operate H.V. condition changing apparatus Unit of competency
Replaced By
State Code National Code Title Type
ODX83 UEPOPS114 Operate H.V. condition changing apparatus Unit of competency