Unit of competency Outline

Date retreived
22/07/2026 5:38 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate and monitor brine concentrator plant

Operate and monitor brine concentrator plant

Unit of competency
National Code
UEPOPS324B
State Code
WE347
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
25/07/2012
State Implementation and Classification
Approved Date
22/07/2014
Field of Education
030717 - Plant And Machine Operations
Original Release Date
22/07/2014
Nominal Hours
27
Description
1)Scope:1.1) DescriptorThis unit deals with the skills and knowledge required to operate, inspect and monitor of brine concentrator plant.
Notes
Elements and Performance Criteria
1 Plan and prepare work
  • 1.1 Safety issues are identified to comply with enterprise/site requirements
  • 1.2 Work requirements are identified from relevant personnel and documentation
  • 1.3 Documentation to determine plant status is assessed and evaluated
  • 1.4 Localised plant inspection and field preparation for service are carried out in accordance with manufacturer and enterprise procedures
  • 1.5 Plant operational pre-requisites are established in accordance with manufacturer and enterprise procedures
  • 1.6 Sequence for recommissioning of plant is determined to suit existing circumstances in accordance with enterprise/site requirements
  • 1.7 Where appropriate, the teams and individuals roles and responsibilities within the team are identified and, where required, assist in the provision of the on-the-job training
2 Operate plant
  • 2.1 Plant is operated in accordance with enterprise and manufacturer operating procedures
  • 2.2 Plant is monitored and observed to detect deviations from normal operating conditions
  • 2.3 Corrective actions taken to rectify abnormalities in accordance with manufacturer and enterprise procedures
  • 2.4 Plant to be removed from service is locally identified and removed from service in accordance with enterprise/site requirements
  • 2.5 Corrective actions are taken in accordance with enterprise safety rules and site requirements when abnormalities are identified during the removal from service
3 Test plant operation
  • 3.1 Tests are performed in accordance with defined procedures applicable to the operational test
  • 3.2 Plant is observed for correct operational response
  • 3.3 Corrective action is taken when response is not in accordance with documentation, plant integrity or personnel safety requirements
  • 3.4 Plant is returned to required operational status upon completion of test
4 Analyse plant faults
  • 4.1 Cause of abnormal plant operating conditions are identified by analysing the technical and operational information in a logical and sequential manner
  • 4.2 Corrective action taken is in accordance with enterprise/site procedures
  • 4.3 Plant integrity and personnel safety is maintained through consultation with appropriate personnel, and with reference to plant, technical and operational documentation
5 Monitor and inspect plant
  • 5.1 Plant to be monitored/inspected is physically identified
  • 5.2 Plant is monitored/inspected for normal operation or to detect deviations
  • 5.3 Corrective action taken is in accordance with enterprise/site procedures
6 Complete documentation
  • 6.1 Documentation is updated and plant problems, movements, abnormalities and status are reported and logged in accordance with enterprise/site procedures
RANGE STATEMENT
10) This relates to the unit of competency as a whole providing the range of contexts and conditions to which the Performance Criteria apply. It allows for different work environments and situations that will affect performance.
Systems, plant and/or equipment may include electric boiler and associated auxiliaries; electrical supply switchboard(s) and transformers; vapour compressor; centrifuges; electrical motors; valves, actuators and dampers (electric, hydraulic, pneumatic and manual); supervisory, protection alarm and control equipment; safety showers and eyewash equipment; pumps; heat exchangers; de-aerator; and process chemicals storage and handling equipment.
Safety standards may include relevant sections of Occupational Health and Safety legislation, enterprise safety rules, relevant state and federal legislation, national standards for plant and Australian standards.
Information and documentation sources may include verbal and written communications, enterprise/site safety rules documentation/form(s), enterprise/site operating instructions, enterprise/site log book, manufacturer operation and maintenance manuals, dedicated computer equipment, equipment and alarm manuals, enterprise standing instructions and plant notes.
Technical and operational indicators may include stimuli (audio, smell, touch, visual), remote or local indicators and recorders and alarms (visible and or audible).
Communications may be by means of telephone, two way radio, pager, computer (electronic mail), operating log (written or verbal) and public address system.
Tests may include stand-by plant “cut-in” tests and motor direction checks.
Appropriate personnel to consult, give or receive direction may include supervisor/team leader or equivalent, technical and engineering officers or equivalent, maintenance staff, power plant operations personnel or equivalent, other operating staff or equivalent and contractor staff.
Test, fault finding and operating tools may include high voltage testers, providing dead equipment, power or hand tools and pH meters.
Operating environment may be, remote from plant, aided by indicators and monitors, during inclement or otherwise harsh weather conditions, wet/noisy/dusty/ hot areas and during continuous operation.
Faults and abnormal operating conditions may include motor/pump/ actuator/valve/ damper failure/malfunctions, control equipment failure/ malfunctions, loss of electrical supply to plant and equipment, process chemical limits exceeded, process chemicals leaks/spillages and excessive vibration pumps/motors.
Generic terms are used throughout this Training Package for vocational standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms are given in Section 2.1 Preliminary Information and Glossaries.
EVIDENCE GUIDE
9) This provides essential advice for assessment of the unit of competency and must be read in conjunction with the Performance Criteria and the Range Statement of the unit and the Training Package Assessment Guidelines.
The Evidence Guide forms an integral part of this Competency Standard Unit and shall be used in conjunction with all components parts of this unit and, performed in accordance with the Assessment Guidelines of this Training Package.

Overview of Assessment
9.1)

Longitude competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the Industry’s preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accord with Industry and, Regulatory policy in this regard.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Hence, sources of evidence need to be ‘rich’ in nature so as to minimise error in judgment.
Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data gathered will contribute to its ‘richness’. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.

Critical aspects of evidence required to demonstrate competency in this unit
9.2)

Before the critical aspects of evidence are considered all pre-requisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated Performance Criteria shall be demonstrated on at least two occasions in accordance with the “Assessment Guidelines - UEP12”. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the Performance Criteria and Range Statement
Apply sustainable energy principles and practices as specified in the Performance Criteria and Range Statement
Demonstrate an understanding of the essential knowledge and associated skills as described in 6) Essential Knowledge and Associated Skills of this unit
Demonstrate an appropriate level of employability skills
Conduct work observing the relevant Anti Discrimination legislation, regulations, polices and workplace procedures
Demonstrated performance across a representative range of contexts from the prescribed items below:
Knowledge and application of relevant sections of: Occupational Health and Safety legislation; Statutory legislation; Enterprise/site safety procedures; Enterprise/site emergency procedures
Preparation and planning of work
Operation of brine concentrator plant
Operationally testing plant
Analysing plant faults
Monitoring plant operation
Knowledge of the properties of gases, their use and precautions to be taken
Dealing with an unplanned event by drawing on essential knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items

Context of and specific resources for assessment
9.3)

This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this unit.
Competency Standards should be assessed in the workplace or simulated workplace and under the normal range of workplace conditions.
Assessment of this unit will be supported with documentary evidence, by means of endorsement stating type and application of work.
In addition to the resources listed above in Context of assessment’, evidence should show competency working, in limited spaces, with different types of plant and equipment as well as different structural/construction types and methods and in a variety of environments.

Method of assessment
9.4)

This unit shall be assessed by methods given in Section 1.3.00 Assessment Guidelines.
Note: Competent performance with inherent safe working practices is expected in the Industry to which this unit applies. This requires that the specified essential knowledge and associated skills are assessed in a structured environment which is primarily intended for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the essential knowledge and skills described in this unit.

Concurrent assessment and relationship with other units
9.5)

There are no recommended concurrent assessments with this unit, however in some cases efficiencies may be gained in terms of learning and assessment effort being concurrently managed with allied competency standard units where listed.
Nil
Replaces
State Code National Code Title Type
S5210 UEPOPS324A Operate and Monitor Brine Concentrator Plant Unit of competency
Replaced By
State Code National Code Title Type
OAH04 UEPOPS324 Operate and monitor brine concentrator plant Unit of competency