Unit of competency Outline

Date retreived
22/07/2026 4:46 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Perform basic magnetic particle testing

Perform basic magnetic particle testing

Unit of competency
National Code
MEM24003B
State Code
W5701
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
01/12/2005
State Implementation and Classification
Approved Date
30/06/2011
Field of Education
030305 - Materials Engineering
Original Release Date
30/06/2011
Nominal Hours
18
Description
This unit covers performing basic magnetic particle testing procedures in a range of industrial applications. It covers the principles of magnetism and the associated application of basic magnetic particle testing techniques in the field of non-destructive testing. Knowledge of metallurgy associated with the level of application in this unit is required.
Notes
Elements and Performance Criteria
1. Prepare inspection areas for basic magnetic particle testing
  • 1.1. Inspection areas are cleaned and prepared for testing using appropriate procedures and materials.
  • 1.2. Preparation processes are carried out in accordance with the relevant specifications and OH&S requirements.
  • 1.3. Inspection areas are visually assessed and obvious discontinuities are identified.
2. Perform basic magnetic particle testing
  • 2.1. Nominated 'yoke' or 'bench' magnetic particle testing procedure is identified from standard operating procedures.
  • 2.2. Test equipment is prepared in accordance with relevant standards and/or procedures.
  • 2.3. Magnetic particle test is carried out in accordance with relevant work instructions and OHS requirements.
  • 2.4. Magnetic particle testing equipment is maintained and stored in accordance with standard operating procedures and OH&S requirements.
3. Report the results of magnetic particle test(s)
  • 3.1. Basic indications are checked and defects are identified in accordance with enterprise standards and/or procedures.
  • 3.2. Basic indications are confirmed in accordance with enterprise standards and/or procedures.
  • 3.3. Test results are reported in accordance with enterprise standards and/or procedures.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Preparation processes
Surface cleaning and drying
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to perform basic magnetic particle testing. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with performing basic magnetic particle testing procedures in a range of industrial applications or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaces
State Code National Code Title Type
M1489 MEM24.3AA Perform basic magnetic particle testing Unit of competency
Replaced By
State Code National Code Title Type
OEU03 MEM24003 Perform basic magnetic particle testing Unit of competency