Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Design fire sprinkler systems using pre-calculated charts and tables

Design fire sprinkler systems using pre-calculated charts and tables

Unit of competency
National Code
CPCPFS3030
State Code
OCO34
TGA Status
Current
DTWD Status
Approved
Current Release Number
3.00
Current Release Date
09/12/2021
State Implementation and Classification
Approved Date
01/06/2021
Field of Education
039905 - Fire Technology
Original Release Date
01/06/2021
Nominal Hours
24
Description
This unit of competency specifies the skills and knowledge required to design fire sprinkler systems using pre-calculated tables and charts.In some jurisdictions, this unit of competency may form part of accreditation, licensing, legislative, regulatory or certification requirements.
Notes
Elements and Performance Criteria
1 Prepare for work.
  • 1.1 Obtain scope of work requirements from information and quality requirements, including relevant job plans and specifications, codes, Australian Standards, manufacturer’s specifications and jurisdictional requirements.
  • 1.2 Identify and apply workplace policies and procedures, work health and safety (WHS) and environmental requirements.
  • 1.3 Set up work area to enable sprinkler system to be designed efficiently.
2 Identify design requirements.
  • 2.1 Obtain data from relevant job specifications required to prepare design.
  • 2.2 Identify building classification and hazard ratings that apply to the fire sprinkler system being designed.
  • 2.3 Identify ceiling type and constructions material.
  • 2.4 Identify all features of that building that might obstruct the spray pattern of the sprinkler, i.e. bulkheads, beams, columns, etc.
  • 2.5 Identify sprinkler head type from relevant job plans and specifications, codes, Australian Standards, manufacturer’s specifications and jurisdictional requirements.
  • 2.6 Identify the requirement for concealed space sprinklers.
  • 2.7 Water supply needs are established and graphs are drawn for the automatic fire sprinkler system.
3 Design sprinkler system.
  • 3.1 Identify and locate the control valves.
  • 3.2 Lay out sprinkler locations according to AS 2118.1 Automatic fire sprinkler systems – General systems and manufacturer data sheets.
  • 3.3 Lay out the range and distribution pipework in an economical manner.
  • 3.4 Determine the most remote last range type.
  • 3.5 Locate the design points.
  • 3.6 Size all range pipes in the installation using the pre-calculated tables.
  • 3.7 Size the distribution pipework up to the design point using the pre-calculated tables.
  • 3.8 Size the distribution pipework from the design point to the control valve using hydraulic calculations.
  • 3.9 Prepare fabrication design sheets and material lists.
4 Finalise work.
  • 4.1 Clear the work area, and dispose of, reuse or recycle materials in accordance with state and territory legislation and workplace policies and procedures.
  • 4.2 Apply workplace recording and reporting procedures where required.