Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Respond to a critical incident

Respond to a critical incident

Unit of competency
National Code
UEPOPS369
State Code
OAG67
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
31/10/2018
State Implementation and Classification
Approved Date
15/05/2019
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
15/05/2019
Nominal Hours
36
Description
This unit involves the skills and knowledge required to respond to a critical incident that may impact the operational effectiveness of a power generation facility's plant or system, endanger human life, damage or destroy property and/or have an adverse impact on the environment.A critical incident refers to a crisis that may result in a high level of risk, directly or indirectly, to the core operations of a power generation facility. A high levelof risk would be determined using the risk management processes outlined in the power generation facility's Risk Management System.Competency in this unit requires the ability to identify a critical incident and consequences, stabilise power generation system, restore power generation system and review response to incident. Individuals will, in general, work as an operator, in a power generation facility.Power generation plant operators are typically trained and authorised to isolate, prepare plant and issue permits to work.No licensing, legislative or certification requirements apply to this unit at the time of publication.Note: Workplace practiceThe application of the skills and knowledge described in this unit may require a licence or training permit to practice in the workplace where work is carried out on gas and electrical installations. Additional conditions may apply under state and territory legislative and regulatory licensing requirements.
Notes
Elements and Performance Criteria
1 Identify critical incident and consequences
  • 1.1 Information and documentation to determine power generation system status, and consequences of critical incident is analysed, in accordance with workplace procedures, legislative requirements, industry standards and Work, Health and Safety (WHS)/Occupational Health and Safety (OHS) regulations
  • 1.2 Fault location is determined by monitoring and evaluating power generation system configuration and operational prerequisites, in accordance with workplace procedures
  • 1.3 Fault information is collated, in accordance with workplace procedures, to determine type and cause of failure
  • 1.4 Power generation system limitations and performance, including location and any external influences, are identified, in accordance with workplace procedures
2 Stabilise power generation system
  • 2.1 Appropriate critical incident response techniques are identified and used, in accordance with workplace procedures
  • 2.2 Appropriate personnel and external stakeholders are consulted, in accordance with workplace procedures, prior to further critical incident actions being undertaken
  • 2.3 Power generation system requirements are assessed, and controlled, to maintain stability and integrity, in accordance with workplace procedures
  • 2.4 Corrective actions to rectify power generation system abnormalities are implemented, following analysis of data, in accordance with workplace procedures
3 Restore power generation system
  • 3.1 Specialised assistance, if required, is identified, in accordance with workplace procedures
  • 3.2 Strategies to restore power generation system integrity are identified, and communicated to appropriate personnel, in accordance with workplace procedures
  • 3.3 Power generation system restoration is undertaken, and is monitored and adjusted, in accordance with workplace procedures
4 Review response to incident
  • 4.1 Power generation system response is analysed, in accordance with workplace procedures
  • 4.2 Critical incident preventive measures are documented, in accordance with workplace procedures
  • 4.3 Findings are communicated to appropriate personnel and key stakeholders, in accordance with workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WE384 UEPOPS369A Respond to a critical incident Unit of competency
Replaced By
State Code National Code Title Type
ODY51 UEPOPS130 Respond to a critical incident Unit of competency