Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install LPG storage of aggregate storage capacity exceeding 500 litres and less than 8KL
Install LPG storage of aggregate storage capacity exceeding 500 litres and less than 8KL
Unit of competency
National Code
CPCPGS3060A
CPCPGS3060A
State Code
WF906
WF906
TGA Status
Replaced
Replaced
DTWD Status
Transition (Replaced)
Transition (Replaced)
State Implementation and Classification
Approved Date
20/06/2014
Field of Education
040327 - Plumbing
Original Release Date
20/06/2014
Nominal Hours
8
Description
This unit of competency specifies the outcomes required to select, locate, install and test liquefied petroleum gas (LPG) storage facilities with a storage capacity of more than 500 litres but less than 8KL.The storage is connected to consumer piping systems with an operating pressure not exceeding 140kPa.
Notes
Elements and Performance Criteria
1 Identify installation requirements.
- 1.1 Building plans and specifications and any special instructions are obtained.
- 1.2 Work health and safety (WHS) and environmental requirements associated with installing LPG storage facilities are adhered to throughout the work.
- 1.3 Quality assurance requirements for company operations are identified and adhered to.
- 1.4 Gas load and design requirements are determined from plans, specifications, and job drawing or workplace instructions.
- 1.5 Storage capacity is checked for compliance with regulatory authorities’ and installation requirements.
- 1.6 Appropriate regulators are determined to meet capacity and load of the system according to installation requirements.
- 1.7 Appropriateness of selected location to provide required service is established in compliance with standards and installation requirements.
- 1.8 Quantity of required materials is calculated from design, drawings and specifications in compliance with installation requirements.
2 Prepare for installation.
- 2.1 Materialsand equipment are ordered and checked for compliance with docket and order form, and for acceptable condition.
- 2.2 Appropriate tools and equipment for installation of storage facility, including personal protective equipment, are identified, selected and checked for serviceability.
- 2.3 Appropriate testing apparatus is selected.
- 2.4 Work is planned in conjunction with others involved in or affected by the work.
- 2.5 Work area and materials are prepared to support efficient installation of system.
3 Install and test LPG storage system.
- 3.1 LPG containers, piping, fittings and components are installed in compliance with standards and installation requirements.
- 3.2 Regulators and associated pipework are installed in compliance with standards and installation requirements.
- 3.3 Regulators are adjusted to provide working pressure in compliance with standards and installation requirements.
- 3.4 System is purged according to standards.
- 3.5 System is tested in compliance with standards and installation requirements.
- 3.6 Test equipment is removed and test data recorded in format required by regulatory authority and installation requirements.
- 3.7 Sustainability principles and concepts are applied throughout the installation process.
4 Clean up.
- 4.1 Work area is cleared and materials disposed of, reused or recycled according to legislation, regulations, codes of practice and job specification.
- 4.2 Tools and equipment are cleaned, checked, maintained and stored according to manufacturer recommendations and workplace procedures.
- 4.3 Informationis accessed and documentation completed according to installation requirements.
- 4.4 Relevant authorities and supervisors are advised of job completion in compliance with regulatory and installation requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
identifying and testing for electrical hazards
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials for installing LPG storage facilities:
may include:
container supports and bases
copper tubing
fitting and fixing materials
gas containers (500L-8KL)
gas regulators
non-metallic hose assemblies
other approved materials
are to comply with job specifications and appropriate standards for the storage of LPG.
Tools and equipment may include:
brazing equipment
chain blocks
flaring tools
forklifts
grinders
hacksaws
hand and power tools
hand trolleys
hoists and jacks
ladders
lifting and load shifting equipment
measuring equipment
rollers
pressure testing equipment.
Installation is normally a two stage system and:
may be from storage container:
to point of use, requiring regulators
from storage to a second stage regulator
installation and materials are to be according to relevant standards.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
efficient use of material
efficient energy usage
selecting appropriate material to ensure minimal environmental impact.
Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing and/or gasfitting authority regulations
relevant Australian standards
safe work procedures relating to determining requirements, and installing and testing LPG storage systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
identifying and testing for electrical hazards
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials for installing LPG storage facilities:
may include:
container supports and bases
copper tubing
fitting and fixing materials
gas containers (500L-8KL)
gas regulators
non-metallic hose assemblies
other approved materials
are to comply with job specifications and appropriate standards for the storage of LPG.
Tools and equipment may include:
brazing equipment
chain blocks
flaring tools
forklifts
grinders
hacksaws
hand and power tools
hand trolleys
hoists and jacks
ladders
lifting and load shifting equipment
measuring equipment
rollers
pressure testing equipment.
Installation is normally a two stage system and:
may be from storage container:
to point of use, requiring regulators
from storage to a second stage regulator
installation and materials are to be according to relevant standards.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include:
efficient use of material
efficient energy usage
selecting appropriate material to ensure minimal environmental impact.
Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing and/or gasfitting authority regulations
relevant Australian standards
safe work procedures relating to determining requirements, and installing and testing LPG storage systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements, and select, locate, install and test LPG storage systems
applying safety requirements throughout the work sequence, including applying equipotential bonding procedures and using personal protective clothing and equipment
given the plans and specifications for a gas storage facility of capacity greater than 500 litres (but less than 8KL), determining the requirements, installing and testing first and second stage piping installation from an LPG storage container located and installed to specifications, ensuring:
application of sustainability principles and concepts
correct identification of location, design and details of proposed storage installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements, and select, locate, install and test LPG storage systems
applying safety requirements throughout the work sequence, including applying equipotential bonding procedures and using personal protective clothing and equipment
given the plans and specifications for a gas storage facility of capacity greater than 500 litres (but less than 8KL), determining the requirements, installing and testing first and second stage piping installation from an LPG storage container located and installed to specifications, ensuring:
application of sustainability principles and concepts
correct identification of location, design and details of proposed storage installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| D9307 | CPCPGS3035A | Install LPG storage of aggregate storage capacty exceeding 500 litres and less than 8KL | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OCN18 | CPCPGS3060 | Install LPG storage of aggregate storage capacity exceeding 500 litres and less than 8 kl | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J789 | CPC32713 | Certificate III in Gas Fitting | Qualification |
| J787 | CPC32413 | Certificate III in Plumbing | Qualification |
| J788 | CPC32513 | Certificate III in Plumbing (Mechanical Services) | Qualification |