Qualification Outline

Date retreived
22/07/2026 10:08 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate III in Gas Fitting

Certificate III in Gas Fitting

Qualification
National Code:
CPC32713
State Code:
J789
TGA Status:
Replaced
DTWD Status:
Replaced
National Endorsed, State Implementation and Classification
Field of Education
0403 - Building
Original TGA Release Date
17/01/2014
Approved Date
20/06/2014
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
C
Nominal Hours
639
Duration
2 Semesters
Current Release Number
3.00
Current Release Date
11/11/2021
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
3.00 11/11/2021 Current Approved
2.00 17/01/2017 Replaced Approved
1.00 17/01/2014 Replaced Approved
Description

This qualification provides a trade outcome in gas fitting.
Occupational titles may include:
Gas fitter.
The qualification has core and elective unit of competency requirements that cover some common skills for the plumbing industry, as well as gas fitting specialist units of competency.
The plumbing industry strongly affirms that training and assessment leading to recognition of skills must be undertaken in a real or very closely simulated workplace environment and this qualification requires all units of competency to be delivered in this context.
Completion of the general induction training program specified by the National Code of Practice for Induction Training for Construction Work (ASCC 2007) is required before entering a construction work site. Achievement of unit CPCCOHS1001A covers this requirement.

Schedule
Packaging Rules
To achieve this qualification, the candidate must demonstrate competency in:
Thirty two (32) units of competency:
- twenty six (26) core units
- six (6) elective units.

Some units in this qualification may have prerequisite requirements, which must be met when packaging the qualification. Users are referred to the list of CPC08 units with prerequisite unit requirements available in this Training Package for this purpose.

Restricted Permit Class G
The Certificate III in Gas Fitting (CPC32713) including the following units:
- CPCPCM2041A Work effectively in the plumbing and services sector
- CPCPCM2043A Carry out WHS requirements
- CPCPCM2046A Use plumbing hand and power tools
- CPCPCM2052A Weld using oxy-acetylene equipment

Unrestricted Permit Class G Installation
The Certificate III in Gas Fitting (CPC32713) including the following units:
- CPCPCM2041A Work effectively in the plumbing and services sector
- CPCPCM2043A Carry out WHS requirements
- CPCPCM2046A Use plumbing hand and power tools
- CPCPCM2052A Weld using oxy-acetylene equipment
- CPCPCM3022A Weld polyethlene and polypropylene pipes using fusion method
- CPCPGS3055A Install gas sub-meters
- CPCPGS4011C Design and size consumer gas installations

This is a licensed occupation.
1. Core Units

All twenty six (26) units must be completed.

State Code National Code Title Hours Type
WF900 CPCPGS3054A Calculate and install natural ventilation for Type A gas appliances 12 Unit of competency
WE999 CPCPCM2039A Carry out interactive workplace communication 12 Unit of competency
WF836 CPCPCM2047A Carry out levelling 12 Unit of competency
WF833 CPCPCM2043A Carry out WHS requirements 34 Unit of competency
WF837 CPCPCM2048A Cut and join sheet metal 16 Unit of competency
WF896 CPCPGS3053A Disconnect and reconnect Type A gas appliances 16 Unit of competency
WF844 CPCPCM3021A Flash penetrations through roofs and walls 30 Unit of competency
WF834 CPCPCM2045A Handle and store plumbing materials 12 Unit of competency
WI774 CPCPGS3061A Install and commission Type A gas appliances 24 Unit of competency
WF902 CPCPGS3056A Install gas piping systems 24 Unit of competency
WF894 CPCPGS3048A Install gas pressure control equipment 12 Unit of competency
WF905 CPCPGS3059A Install LPG storage of aggregate storage capacity up to 500 litres 12 Unit of competency
WF892 CPCPGS3046A Install LPG systems in caravans, mobile homes and mobile workplaces 20 Unit of competency
WF893 CPCPGS3047A Install LPG systems in marine craft 4 Unit of competency
WF895 CPCPGS3049A Install Type A gas appliance flues 10 Unit of competency
WF899 CPCPGS3052A Maintain Type A gas appliances 8 Unit of competency
WF839 CPCPCM2050A Mark out materials 16 Unit of competency
WD144 HLTFA211A Provide basic emergency life support 10 Unit of competency
WF897 CPCPGS3051A Purge consumer piping 6 Unit of competency
WF831 CPCPCM2040A Read plans and calculate plumbing quantities 12 Unit of competency
WF903 CPCPGS3057A Size consumer gas piping systems 12 Unit of competency
WF835 CPCPCM2046A Use plumbing hand and power tools 16 Unit of competency
WF841 CPCPCM2053A Weld using manual metal arc welding equipment 8 Unit of competency
WF840 CPCPCM2052A Weld using oxy-acetylene equipment 8 Unit of competency
WF832 CPCPCM2041A Work effectively in the plumbing and services sector 16 Unit of competency
WF843 CPCPCM2055A Work safely on roofs 15 Unit of competency
2. Elective Units

Six (6) units to be completed.
Please refer to the Training Package for the full list of available elective units.

State Code National Code Title Hours Type
W9435 CPCCOHS2001A Apply OHS requirements, policies and procedures in the construction industry 32 Unit of competency
WF913 CPCPMS2021A Assemble mechanical services components 12 Unit of competency
W9555 CPCCST2005A Carry out load slinging of off-site materials 4 Unit of competency
WF842 CPCPCM2054A Carry out simple concreting and rendering 24 Unit of competency
WF838 CPCPCM2049A Cut using oxy-LPG-acetylene equipment 8 Unit of competency
WE986 CPCCCM2008B Erect and dismantle restricted height scaffolding 16 Unit of competency
WF846 CPCPCM3023A Fabricate and install non-ferrous pressure piping 8 Unit of competency
WF914 CPCPMS3031A Fabricate and install steel pressure piping 52 Unit of competency
WF918 CPCPMS3035A Install and test ducting systems 12 Unit of competency
WF901 CPCPGS3055A Install gas sub-meters 6 Unit of competency
WF906 CPCPGS3060A Install LPG storage of aggregate storage capacity exceeding 500 litres and less than 8KL 8 Unit of competency
WF916 CPCPMS3033A Install small bore heating systems 12 Unit of competency
WH086 RIICCM210D Install trench support 8 Unit of competency
WE988 CPCCCM3001C Operate elevated work platforms 16 Unit of competency
W9484 CPCCRI3001A Operate personnel and materials hoists 24 Unit of competency
W5326 MEM05050B Perform routine gas metal arc welding 18 Unit of competency
W5324 MEM05049B Perform routine gas tungsten arc welding 18 Unit of competency
WF845 CPCPCM3022A Weld polyethylene and polypropylene pipes using fusion method 8 Unit of competency
WE987 CPCCCM2010B Work safely at heights 16 Unit of competency
Replaces
State Code National Code Title Type
J494 CPC32712 Certificate III in Gas Fitting Qualification
Replaced By
State Code National Code Title Type
BGB7 CPC32720 Certificate III in Gas Fitting Qualification
No information
Entry Requirements

Not applicable.

Traineeships and Apprenticeships
No information