Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Terminate metallic conductor customer cable
Terminate metallic conductor customer cable
Unit of competency
National Code
ICTCBL203
ICTCBL203
State Code
AWG39
AWG39
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
05/07/2016
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
05/07/2016
Nominal Hours
60
Description
This unit describes the skills and knowledge required to terminate metallic conductor cable or join cable in a terminating block for a new cable installation or upgrade of cable capacity for an existing network or subsystem, or cabling infrastructure for convergence to next generation networks (NGN).It applies to individuals who work in technical roles carrying out indoor and outdoor, domestic, commercial or industrial installations for all communications applications, digital and analog, telephony, data, video, digital broadcasting, computer networks, local area networks (LAN), wide area networks (WAN) and multimedia.All customer cabling work in the telecommunications, fire, security and data industries must be performed by a registered cabler. All cablers are required to register with an Australian Communications and Media Authority (ACMA) accredited registrar.
Notes
Elements and Performance Criteria
1. Prepare cable termination
- 1.1 Arrange access according to customer and individual worksite requirements
- 1.2 Prepare for cable terminating work within regulatory environment, cabling environment, cable type, cable identification, termination systems, earthing and protection, records and relevant legislation, codes, regulations and standards
- 1.3 Select correct termination for installation according to strategies to manage infrastructure and relevant legislation, codes, regulations and standards
- 1.4 Notify appropriate personnel of identified safety hazards at cabling worksite
- 1.5 Identify remote power feeding services that operate at above telecommunications network voltage (TNV) inside customer premises, and risks posed by contact with remote power feed
- 1.6 Remove all contaminants from worksite that may adversely affect termination and prepare worksite to ensure adequate visibility to minimise errors and reduce eye strain
- 1.7 Design cable and block location within frame with capacity for expansion where possible
- 1.8 Segregate incoming and outgoing cables for ease of access and to minimise overlaying and backtracking of cable
2. Terminate cable
- 2.1 Remove cable sheath to allow for conductor length and installation requirements
- 2.2 Fan out cable pair groups to manufacturer’s coding system to ensure correct terminating sequence and unique identification where appropriate
- 2.3 Install over-voltage protection devices to all cables with metallic component where required
- 2.4 Install terminating modules to frame according to manufacturer’s specifications
- 2.5 Fan cable pairs neatly to termination equipment to facilitate accurate termination
- 2.6 Terminate cable following work health and safety (WHS) and environmental requirements to manufacturer’s specifications using correct tool
- 2.7 Earth cable shield to manufacturer’s specifications and industry standards
3. Test termination
- 3.1 Conduct visual inspection to confirm that termination colour code sequence has been followed
- 3.2 Test termination to satisfy performance specifications and record results if required
4. Complete records and clean up site
- 4.1 Label cable pairs clearly to provide an accurate identification according to manufacturer, industry and customer standards
- 4.2 Update records and plans with cabling details to provide accurate record according to industry codes of practice and current Australian standards
- 4.3 Complete telecommunications cabling advice (TCA) forms and provide to customer
- 4.4 Remove installation waste and debris from worksite and dispose of according to environmental requirements to maintain safe worksite conditions
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| D3300 | ICTCBL2008A | Terminate metallic conductor customer cable | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OBA73 | ICTCBL241 | Terminate metallic conductor customer cable | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| AZM3 | CUA30815 | Certificate III in Broadcast Technology | Qualification |
| AZJ6 | ICT20315 | Certificate II in Telecommunications Technology | Qualification |
| AZI6 | ICT30515 | Certificate III in Telecommunications Technology | Qualification |