Unit of competency Outline

Date retreived
22/07/2026 9:47 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Perform advanced tests on seeds

Perform advanced tests on seeds

Unit of competency
National Code
AHCSDT412
State Code
ODU32
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
15/02/2022
State Implementation and Classification
Approved Date
31/05/2022
Field of Education
019909 - Laboratory Technology
Original Release Date
31/05/2022
Nominal Hours
160
Description
This unit of competency describes the skills and knowledge required to perform advanced tests on seeds and grain to determine quality, performed under laboratory conditions in accordance with Australian and industry standards. Tests to be demonstrated include, Anguina test on annual ryegrass seed, endophytic seed test, electrophoresis test on a seed sample, tetrazolium test, seed vigour test and 1000 seed weight test.The unit applies to senior seed analysts who analyse information and exercise judgement to complete a range of advanced skilled activities and demonstrate deep knowledge in a specific technical area. They have accountability for the work of others and analyse, design and communicate solutions to a range of complex problems. All work is carried out to comply with workplace procedures.Seed to be processed for Certification must be sampled by an Authorised Sampler in accordance with international, federal and state seed certification regulations.
Notes
Elements and Performance Criteria
1. Prepare seed for testing and maintain condition and purity
  • 1.1 Identify purpose and type of seed tests from work instructions
  • 1.2 Verify authenticity of seed from submitted sample documentation
  • 1.3 Verify submitted seed sample complies with condition specified for seed test and report inconsistences to supervisor
  • 1.4 Select and implement correct personal protective equipment (PPE)
  • 1.5 Prepare working test sample/s from submitted seed sample according to workplace and laboratory procedures
  • 1.6 Store and maintain condition and quality of seed samples for testing according to seed species, workplace procedures and industry standards
  • 1.7 Implement procedures to prevent contamination of submitted sample and working samples
  • 1.8 Label and record working samples according to workplace and industry standards for traceability
2. Prepare equipment and materials for seed tests
  • 2.1 Select number of replicates for seed test according to specified test procedure and work instructions
  • 2.2 Prepare the required number of replicates according to specific test procedures and industry standards
  • 2.3 Label and store replicates according to workplace procedures and industry standards
  • 2.4 Compile and prepare materials required according to specified seed test procedures
  • 2.5 Select, clean, check and calibrate test equipment according to manufacturer seed test specifications
  • 2.6 Rectify or arrange repair of faulty equipment according to workplace procedures
  • 2.7 Update records of equipment faults, repairs and calibration
  • 2.8 Identify health and safety hazards, assess risk and implement controls according to workplace procedures
3. Implement seed testing procedures
  • 3.1 Measure quantities of seed required for each test replicate according to test procedures
  • 3.2 Pre-treat or condition seed replicates ready for testing according to test procedures
  • 3.3 Conduct seed test according to seed test procedures and industry standards
  • 3.4 Maintain conditions to maintain quality and prevent contamination of replicates during testing process
  • 3.5 Update labelling of replicates and records according to workplace and industry standards for traceability
4. Examine and assess tested seed
  • 4.1 Identify endpoint of test and prepare replicates for assessment according to testing procedures
  • 4.2 Examine each replicate and record observations
  • 4.3 Assess observations against standards specified in workplace and industry procedures
  • 4.4 Record observations and test results according to workplace and industry procedures
5. Prepare and report test results
  • 5.1 Calculate test results according to workplace procedures and industry standards
  • 5.2 Compile and document test results
  • 5.3 Assess test results against standards and report results according to workplace procedures
  • 5.4 Update records according to workplace and industry standards for traceability
6. Finalise testing procedures
  • 6.1 Dispose of replicates and waste according to testing protocols and workplace waste and biosecurity procedures
  • 6.2 Clean and store test equipment according to workplace procedures
No information
No information