Unit of competency Outline
Date retreived
23/07/2026 5:51 AM AWST
23/07/2026 5:51 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Work safely with live fibre to test and commission a fibre to the x installation
Work safely with live fibre to test and commission a fibre to the x installation
Unit of competency
National Code
ICTBWN3100A
ICTBWN3100A
State Code
D3296
D3296
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
26/11/2013
Field of Education
061301 - Occupational Health And Safety
Original Release Date
26/11/2013
Nominal Hours
45
Description
This unit describes the performance outcomes, skills and knowledge required to work safely on a live optical fibre installation to test and commission a wave division multiplexing (WDM) system or connect a splitter for fibre to the x (FTTx) deployment.Optical networks and FTTx are part of the strategies by service providers using WDM to deliver very high speed broadband capacity through the access network for the National Broadband Network (NBN) initiative.No licensing, legislative, regulatory or certification requirements apply to this unit at the time of endorsement but users should confirm requirements with the relevant federal, state or territory authority.
Notes
Elements and Performance Criteria
1. Set up and prepare for working with live fibre
- 1.1. Obtain relevant legislation, codes, regulations and standards for compliance when conducting work
- 1.2. Scope the work by obtaining project plan from appropriate personnel and arrange for site access to comply with security arrangements
- 1.3. Notify appropriate personnel of identified safety hazards at the worksite
- 1.4. Determine type of FTTx equipment, components of optical distribution network (ODN) and WDM components from project plan for testing and commissioning
- 1.5. Obtain tools and safety equipment and materials to perform tasks safely and efficiently
- 1.6. Select and use required protective equipment and make site safe and secure for commissioning work
- 1.7. Create a safe working environment by following safe work practices and identifying optical fibre hazards that could cause possible injuries when handling optical fibres and laser-based equipment
2. Connect a splitter input fibre to the feeder cable
- 2.1. Follow occupational health and safety (OHS) and environmental requirements for the given work and identify and avoid other services
- 2.2. Locate the feeder fibre port to be connected
- 2.3. Determine the state (live or not) of the fibre port to be connected and notify transmitter to ensure that power is turned off at the source if the fibre port is live
- 2.4. Connect up connectorised splitter input fibres as instructed by the manufacturer
- 2.5. Arrange for power to be turned back on to the newly connected feeder port
3. Perform live WDM commission testing of a ODN installation used in FTTx network
- 3.1. Locate the appropriate test points in the ODN from manufacturer's instructions for WDM testing
- 3.2. Test live wavelengths for the WDM tests following safety precautions
- 3.3. Test the optical signal strengths for the operating wavelengths incoming into the optical network termination (ONT) and determine if signal strengths are within the range of acceptable power levels
- 3.4. Test the losses between the WDM outputs and the individual LM for each wavelength and determine if within maximum and minimum power losses
- 3.5. Conduct all acceptance tests as specified by manufacturer
- 3.6. Record and tabulate all tests results for commissioning requirements
4. Clean up work site
- 4.1. Seal and secure any enclosures and cabinets
- 4.2. Remove waste and debris from worksite and dispose of according to environmental requirements
- 4.3. Notify appropriate personnel of job completion and obtain sign off
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Relevant legislation, codes, regulations and standards may include:
Australian Communications Industry Forum (ACIF) standards and codes
AS Communications Cabling Manual (CCM) Volume 1
AS/NZS 3000:2007
AS/NZS 3080:2003
AS/NZS 3084:2003
AS/NZS 3085.1:2004
AS/NZS IEC 61935.1:2006
AS/NZS IEC 61935.2:2006
AS/NZS ISO/IEC 14763.3:2007
AS/NZS ISO/IEC 15018:2005
AS/NZS ISO/IEC 24702:2007
cabling security codes and regulations
Environmental Protection Acts
ISO Draft 11801 (International)
OHS
regulated or industry codes of practice including appropriate Australian Communications and Media Authority (ACMA) standards
relevant Institute of Electrical and Electronics Engineers (IEEE) standards
technical standards AS/ACIF S008:2006 and AS/ACIF S009:2006.
Appropriate personnel may be:
consultant
project engineer
project supervisor
site supervisor.
Safety hazards may refer to:
access points that may contain:
hazardous light (non-visible laser)
radio frequency (RF) emission
active lasers with no safety labels
active optical fibres
contact with remote power feed
electrical supply that require mandatory separation from communications cable
exposed fibres
unsafe support structures
unsafe weather:
heavy rains
high winds
severe heat or cold
thunderstorms.
FTTx equipment may include:
add-drop multiplexer
Bragg grating device
lead-in fibre cable
optical amplifier
optical filter
optical splitter.
Components of the optical distribution network (ODN) may include:
distribution fibre
distribution joint acting as and feeding LMs (DLM)
fibre access point (FAP)
fibre distribution hub (FDH)
FDH tail cable
lead-in joint with multiple lead-in ports (LM)
main fibre cable
multi-dwelling unit (MDU)
network termination device (NTD)
optical network termination (ONT)
passive optical network (PON)
power supply unit (PSU)
single dwelling unit (SDU).
WDM components may include:
dispersion compensation module
optical add/drop multiplexer
optical amplifier
optical de-multiplexer
optical multiplexer
transponder
variable optical attenuator.
Tools and safety equipment may include:
personal protective equipment
safety equipment
test equipment:
PON meter
optical time domain reflectometer (OTDR)
tools:
fibre cleaning kit
fibre splicer
labeller
screw drivers
spanners
tagging tool.
Safe work practices may relate to:
applying relevant Australian standards of required health and safety precautions when working with visible and infra-red lasers
avoiding contact with chemicals, breathing in fumes and vapours, and digesting such materials
clearing fibre particles, hazardous solvents or chemicals from site at the completion of the work
ensuring all solvent residues are disposed of according to environmental policy when using a wet cleaning process
gently releasing stored energy in coiled fibre cable
installing dust caps on unplugged fibre connectors
knowing action and treatment of potential accidents
knowing the colour codes used to identify the various types of fibre and what sort of signals these cables would normally carry
labelling active equipment to warn other people of possible hazards
leaving caps at the end of unconnected fibres and unused laser outputs
never unplugging patch leads without first turning off the active equipment
not damaging or obscuring manufacturer warnings or instruction labels of the laser product during installation
not looking directly into the end of a fibre as it may be carrying laser light
not looking into transmitter ports as they may be of active
not using magnifiers in the presence of laser radiation
restraining cable ends to prevent damage to eyes or body
using only built-in or another form of safe light source when examining connectors with a microscope for contamination, chips or fractures
using protective eyewear designed specifically for laser work
using sharps container to dispose of fibre off-cuts.
Optical fibre hazards may relate to:
cleaning alcohol, epoxy resins and other solvents and chemicals may be carcinogenic, cause allergies or be dangerous to health in other ways
cleaning fluids, solvents and other chemicals may be highly inflammable
fibre off-cut damage to eyes and skin
inhalation of fibre off-cuts and particles from vacuum cleaning of worksite
laser damage to eyes
causing personal injury by activating equipment without notifying other staff who may be working remotely on the network.
Possible injuries may include:
damage to lungs from inhalation of fibre off-cuts or particles
damage to retina in eyes
damage to skin from fibre off-cuts
personal injury from cable end whipping when releasing coiled cable.
OHS and environmental requirements may include:
identifying other services, including power and gas
personal protective equipment:
earmuffs
gloves:
leather
plastic
rubber
head protection
masks
protective suits
safety boots
safety glasses
safe working practices, such as the safe use and handling of:
chemicals
materials
tools and equipment
safety equipment:
flashing lights
safety barriers
warning signs and tapes
witches hats
special access requirements
environmental considerations:
clean-up protection
stormwater protection
waste management.
Other services may include:
alarms
electrical services
fire sprinkler systems
gas and water mains
high voltage power
other service provider networks.
Operating wavelengths may include:
1310 nm
1490 nm
1550 nm.
Range of acceptable power levels may include:
-2 to + 2 dBm @ 1310 nm
-26 to -6 dBm @ 1490 nm
-11.5 to +5 dBm @ 1550 nm.
Maximum and minimum power losses may include:
23.3 dB to 15.0 dB @1310 nm
21.6 dB to 8.0 dB @1490 nm
20.9 dB to 9.5 dB @1550 nm.
Acceptance tests may include:
delay
dispersion
optical attenuation and loss measurements
optical power levels
phase.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Relevant legislation, codes, regulations and standards may include:
Australian Communications Industry Forum (ACIF) standards and codes
AS Communications Cabling Manual (CCM) Volume 1
AS/NZS 3000:2007
AS/NZS 3080:2003
AS/NZS 3084:2003
AS/NZS 3085.1:2004
AS/NZS IEC 61935.1:2006
AS/NZS IEC 61935.2:2006
AS/NZS ISO/IEC 14763.3:2007
AS/NZS ISO/IEC 15018:2005
AS/NZS ISO/IEC 24702:2007
cabling security codes and regulations
Environmental Protection Acts
ISO Draft 11801 (International)
OHS
regulated or industry codes of practice including appropriate Australian Communications and Media Authority (ACMA) standards
relevant Institute of Electrical and Electronics Engineers (IEEE) standards
technical standards AS/ACIF S008:2006 and AS/ACIF S009:2006.
Appropriate personnel may be:
consultant
project engineer
project supervisor
site supervisor.
Safety hazards may refer to:
access points that may contain:
hazardous light (non-visible laser)
radio frequency (RF) emission
active lasers with no safety labels
active optical fibres
contact with remote power feed
electrical supply that require mandatory separation from communications cable
exposed fibres
unsafe support structures
unsafe weather:
heavy rains
high winds
severe heat or cold
thunderstorms.
FTTx equipment may include:
add-drop multiplexer
Bragg grating device
lead-in fibre cable
optical amplifier
optical filter
optical splitter.
Components of the optical distribution network (ODN) may include:
distribution fibre
distribution joint acting as and feeding LMs (DLM)
fibre access point (FAP)
fibre distribution hub (FDH)
FDH tail cable
lead-in joint with multiple lead-in ports (LM)
main fibre cable
multi-dwelling unit (MDU)
network termination device (NTD)
optical network termination (ONT)
passive optical network (PON)
power supply unit (PSU)
single dwelling unit (SDU).
WDM components may include:
dispersion compensation module
optical add/drop multiplexer
optical amplifier
optical de-multiplexer
optical multiplexer
transponder
variable optical attenuator.
Tools and safety equipment may include:
personal protective equipment
safety equipment
test equipment:
PON meter
optical time domain reflectometer (OTDR)
tools:
fibre cleaning kit
fibre splicer
labeller
screw drivers
spanners
tagging tool.
Safe work practices may relate to:
applying relevant Australian standards of required health and safety precautions when working with visible and infra-red lasers
avoiding contact with chemicals, breathing in fumes and vapours, and digesting such materials
clearing fibre particles, hazardous solvents or chemicals from site at the completion of the work
ensuring all solvent residues are disposed of according to environmental policy when using a wet cleaning process
gently releasing stored energy in coiled fibre cable
installing dust caps on unplugged fibre connectors
knowing action and treatment of potential accidents
knowing the colour codes used to identify the various types of fibre and what sort of signals these cables would normally carry
labelling active equipment to warn other people of possible hazards
leaving caps at the end of unconnected fibres and unused laser outputs
never unplugging patch leads without first turning off the active equipment
not damaging or obscuring manufacturer warnings or instruction labels of the laser product during installation
not looking directly into the end of a fibre as it may be carrying laser light
not looking into transmitter ports as they may be of active
not using magnifiers in the presence of laser radiation
restraining cable ends to prevent damage to eyes or body
using only built-in or another form of safe light source when examining connectors with a microscope for contamination, chips or fractures
using protective eyewear designed specifically for laser work
using sharps container to dispose of fibre off-cuts.
Optical fibre hazards may relate to:
cleaning alcohol, epoxy resins and other solvents and chemicals may be carcinogenic, cause allergies or be dangerous to health in other ways
cleaning fluids, solvents and other chemicals may be highly inflammable
fibre off-cut damage to eyes and skin
inhalation of fibre off-cuts and particles from vacuum cleaning of worksite
laser damage to eyes
causing personal injury by activating equipment without notifying other staff who may be working remotely on the network.
Possible injuries may include:
damage to lungs from inhalation of fibre off-cuts or particles
damage to retina in eyes
damage to skin from fibre off-cuts
personal injury from cable end whipping when releasing coiled cable.
OHS and environmental requirements may include:
identifying other services, including power and gas
personal protective equipment:
earmuffs
gloves:
leather
plastic
rubber
head protection
masks
protective suits
safety boots
safety glasses
safe working practices, such as the safe use and handling of:
chemicals
materials
tools and equipment
safety equipment:
flashing lights
safety barriers
warning signs and tapes
witches hats
special access requirements
environmental considerations:
clean-up protection
stormwater protection
waste management.
Other services may include:
alarms
electrical services
fire sprinkler systems
gas and water mains
high voltage power
other service provider networks.
Operating wavelengths may include:
1310 nm
1490 nm
1550 nm.
Range of acceptable power levels may include:
-2 to + 2 dBm @ 1310 nm
-26 to -6 dBm @ 1490 nm
-11.5 to +5 dBm @ 1550 nm.
Maximum and minimum power losses may include:
23.3 dB to 15.0 dB @1310 nm
21.6 dB to 8.0 dB @1490 nm
20.9 dB to 9.5 dB @1550 nm.
Acceptance tests may include:
delay
dispersion
optical attenuation and loss measurements
optical power levels
phase.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
use optical power test equipment
evaluate tests results
connect input and output optical fibres to the splitter
conduct live tests measuring optical signals at three WDM wavelengths on optical devices
conduct acceptance tests for commissioning
demonstrate successful completion of the procedures
complete connection recording
comply with all related OHS requirements and work practices.
Context of, and specific resources for assessment
Assessment must ensure:
a telecommunications operations site where an FTTP installation may be tested and commissioned
access to a WDM system and relevant optical splitter
use of tools, equipment and personal protective equipment currently used in industry
relevant regulatory and equipment documentation that impacts on work activities.
Methods of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate using optical power test equipment applying all related OHS requirements and work practices
direct observation of the candidate conducting live tests measuring optical signals at three WDM wavelengths
direct observation of the candidate conducting acceptance tests for commissioning
oral or written questioning to assess required knowledge.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTBWN3082A Perform tests on optical communication system and components
ICTBWN3088A Install optical fibre splitters in fibre distribution hubs
ICTBWN3090A Install lead-in module and cable for fibre to the premises.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
use optical power test equipment
evaluate tests results
connect input and output optical fibres to the splitter
conduct live tests measuring optical signals at three WDM wavelengths on optical devices
conduct acceptance tests for commissioning
demonstrate successful completion of the procedures
complete connection recording
comply with all related OHS requirements and work practices.
Context of, and specific resources for assessment
Assessment must ensure:
a telecommunications operations site where an FTTP installation may be tested and commissioned
access to a WDM system and relevant optical splitter
use of tools, equipment and personal protective equipment currently used in industry
relevant regulatory and equipment documentation that impacts on work activities.
Methods of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
direct observation of the candidate using optical power test equipment applying all related OHS requirements and work practices
direct observation of the candidate conducting live tests measuring optical signals at three WDM wavelengths
direct observation of the candidate conducting acceptance tests for commissioning
oral or written questioning to assess required knowledge.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTBWN3082A Perform tests on optical communication system and components
ICTBWN3088A Install optical fibre splitters in fibre distribution hubs
ICTBWN3090A Install lead-in module and cable for fibre to the premises.
Aboriginal people and other people from a non-English speaking background may have second language issues.
Access must be provided to appropriate learning and assessment support when required.
Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.
In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.
Where applicable, physical resources should include equipment modified for people with special needs.
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WI867 | ICTBWN3100B | Work safely with live fibre to test and commission a fibre to the x installation | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D556 | ICA30111 | Certificate III in Information, Digital Media and Technology | Qualification |