Unit of competency Outline

Date retreived
22/07/2026 12:47 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Paint and fire glass

Paint and fire glass

Unit of competency
National Code
MSFDG3003
State Code
OAK01
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
03/12/2018
State Implementation and Classification
Approved Date
22/05/2019
Field of Education
040323 - Glazing
Original Release Date
22/05/2019
Nominal Hours
70
Description
This unit describes the skills and knowledge required to apply patterns and/or designs to glass with vitreous paints to achieve specific outcomes through the firing of glass.This unit applies to individuals working with designed glass.No licensing or certification requirements exist at the time of publication. Relevant legislation, industry standards and codes of practice within Australia must be applied.
Notes
Elements and Performance Criteria
1. Identify painting and firing requirements
  • 1.1 Identify and follow work health and safety, legislative and workplace procedures
  • 1.2 Identify types and quantities of patterns, designs and materials required from plans or work instructions
  • 1.3 Identify the processes for painting patterns and designs onto glass and achieving specific outcomes through the firing of glass
2. Prepare to paint and fire glass
  • 2.1 Determine painting sequence in a logical order to suit the job
  • 2.2 Select and check tools, equipment and materials for suitability, serviceability and safety prior to use
  • 2.3 Check patterns and design templates against specifications or job order
  • 2.4 Match paint colours against the plan or work order and prepare glass for painting
3. Apply vitreous paint
  • 3.1 Apply paint to the glass surface in accordance with the pattern or design template
  • 3.2 Identify and rectify any problems occurring during the painting operation
4. Conduct firing operations
  • 4.1 Determine firing sequence in a logical order to suit the job
  • 4.2 Check kiln prior to use to ensure it is appropriate for the firing, serviceable and in a safe condition
  • 4.3 Identify and check kiln components and controls, including emergency stops and guards, for correct operation
  • 4.4 Prepare glass for firing and operate, adjust and monitor kiln equipment to ensure correct product quality and output
  • 4.5 Identify and rectify any problems occurring during the firing operation
5. Finalise the work
  • 5.1 Inspect painted and fired glass for quality of work and repair or discard in accordance with workplace procedures
  • 5.2 Clean and store tools, equipment and materials in accordance with workplace procedures
  • 5.3 Clean work area is cleaned and leave in a safe condition and dispose of waste or recycle in accordance with workplace protocols
  • 5.4 Accurately complete required workplace documentation
No information
No information
Replaces
State Code National Code Title Type
WI648 MSFSL3005 Paint and fire glass Unit of competency