Unit of competency Outline
Date retreived
22/07/2026 8:12 AM AWST
22/07/2026 8:12 AM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Install LPG systems in caravans, mobile homes, water craft and mobile workplaces
Install LPG systems in caravans, mobile homes, water craft and mobile workplaces
Unit of competency
National Code
CPCPGS3016A
CPCPGS3016A
State Code
D7453
D7453
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
11/10/2011
Field of Education
040327 - Plumbing
Original Release Date
11/10/2011
Nominal Hours
20
Description
This unit of competency specifies the outcomes required to install and commission liquefied petroleum gas (LPG) systems in caravans, mobile homes, water craft and mobile workplaces.The unit requires the determination of requirements, the installation and commissioning of LPG systems with an operating pressure not exceeding 2.75kPa in caravans, mobile homes, water craft and mobile workplaces. The design requirements of this unit are limited to the application of the design to layout and installation.
Notes
Elements and Performance Criteria
1. Identify LPG system requirements.
- 1.1. Plans, specifications and any special instructions are obtained.
- 1.2. Safety (OHS) requirements associated with installing and commissioning LPG systems in caravans, mobile homes, water craft and mobile workplaces, and workplace environmental requirements, are adhered to throughout the work.
- 1.3. Quality assurance requirements for company operations are identified and adhered to.
- 1.4. Gas load and design requirements are determined from plans, specifications, and job drawing or workplace instructions.
- 1.5. System capacity is calculated to ensure adequacy for the required load and compliance with standards and workplace requirements.
- 1.6. Appropriate regulator and piping are identified in terms of size, connection sizes and capacity, in accordance with standards and workplace requirements.
- 1.7. Location of cylinders, appliances and piping set out is identified in accordance with job requirements and in compliance with standards and workplace requirements.
- 1.8. Quantity of piping, components and fittings are estimated in compliance with standards and workplace requirements.
2. Prepare for installation.
- 2.1. Materials, equipment, appliances and cylinders are ordered and checked for compliance with docket and order form, and for acceptable condition.
- 2.2. Appropriate tools and equipment for installing and commissioning LPG systems in caravans, mobile homes, water craft and mobile workplaces, including personal protective equipment, are identified and selected.
- 2.3. Work is planned in conjunction with others involved in or affected by the work.
- 2.4. Work area and materials are prepared to support efficient installation of the system.
3. Install LPG system, including flue and ventilation.
- 3.1. Cylinders, regulators, associated pipework, appliances and fixings are installed in compliance with manufacturer requirements, standards and workplace requirements.
- 3.2. Compliance plates are located and fitted in accordance with statutory and regulatory authority requirements, standards and workplace requirements.
4. Test and commission LPG system.
- 4.1. Appropriate test equipment is selected.
- 4.2. System is tested in accordance with standards and workplace requirements.
- 4.3. System is adjusted to provide required flow pressure in conformance to standards and workplace requirements.
- 4.4. Test data is recorded in format required by regulatory and workplace requirements.
5. Clean up.
- 5.1. Work area is cleared and materials disposed of or recycled in accordance with state or territory statutory and regulatory authority legislation and workplace procedures.
- 5.2. Tools and equipment are cleaned, checked, maintained and stored in accordance with manufacturer recommendations and workplace procedures.
- 5.3. Information is accessed and documentation completed in accordance with workplace requirements.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials:
may include:
copper tubing
fitting and fixing materials
gas cylinders
gas operated appliances
gas regulators
non-metallic hose assemblies
stainless steel
other approved materials
are to comply with job specifications and appropriate standards for gas installations.
Tools and equipment may include:
chain blocks
files
flaring tools
hacksaws
hand trolleys
hoists and jacks
lifting and load shifting equipment
measuring equipment
power cutting tools
rollers
silver brazing equipment
spanners
testing equipment
wrenches.
LPG system includes:
appliances
cylinders
piping
regulators.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
recognised formulas or tables accepted by the regulatory authority
regulatory and legislative requirements, particularly those pertaining to:
building and gasfitting authority codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to determining requirements, and installing and commissioning LPG systems in caravans, mobile homes, water craft and mobile workplaces
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Safety (OHS) is to be in accordance with commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
hazardous materials and substances
service lines
surrounding structures and facilities
trip hazards
use of tools and equipment
work site visitors and the public
working at heights
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements include:
clean-up protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Materials:
may include:
copper tubing
fitting and fixing materials
gas cylinders
gas operated appliances
gas regulators
non-metallic hose assemblies
stainless steel
other approved materials
are to comply with job specifications and appropriate standards for gas installations.
Tools and equipment may include:
chain blocks
files
flaring tools
hacksaws
hand trolleys
hoists and jacks
lifting and load shifting equipment
measuring equipment
power cutting tools
rollers
silver brazing equipment
spanners
testing equipment
wrenches.
LPG system includes:
appliances
cylinders
piping
regulators.
Statutory and regulatory authorities include:
state or territory statutory authority
statutory gasfitting authority
statutory plumbing authority.
Information may include:
charts and hand drawings
diagrams or sketches
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
recognised formulas or tables accepted by the regulatory authority
regulatory and legislative requirements, particularly those pertaining to:
building and gasfitting authority codes
OHS and environmental requirements
plumbing regulations
relevant Australian standards
safe work procedures relating to determining requirements, and installing and commissioning LPG systems in caravans, mobile homes, water craft and mobile workplaces
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements, and install and commission LPG systems in caravans, mobile homes, water craft and mobile workplaces
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, determine the requirements, install and commission LPG systems in either a caravan, mobile home or mobile workplace and a water craft (or simulated environment) by determining the gas load and storage capacity requirements for two gas appliances in both a caravan and a water craft and installing and commissioning the gas systems for the installations, ensuring:
correct identification of location, design and details of proposed installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to determine requirements, and install and commission LPG systems in caravans, mobile homes, water craft and mobile workplaces
applying safety requirements throughout the work sequence, including the use of personal protective clothing and equipment
as a minimum the ability to, given the plans and specifications, determine the requirements, install and commission LPG systems in either a caravan, mobile home or mobile workplace and a water craft (or simulated environment) by determining the gas load and storage capacity requirements for two gas appliances in both a caravan and a water craft and installing and commissioning the gas systems for the installations, ensuring:
correct identification of location, design and details of proposed installation
correct selection and use of appropriate processes, tools and equipment
completing all work to specification
compliance with regulations, standards and organisational quality procedures and processes
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe working practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W9691 | CPCPGS3006A | Install LPG systems in caravans, mobile homes, water craft and mobile workplaces | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| WF892 | CPCPGS3046A | Install LPG systems in caravans, mobile homes and mobile workplaces | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D414 | CPC32711 | Certificate III in Gas Fitting | Qualification |
| D411 | CPC32411 | Certificate III in Plumbing | Qualification |