Qualification Outline

Date retreived
22/07/2026 6:38 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate III in Gas Fitting

Certificate III in Gas Fitting

Qualification
National Code:
CPC32711
State Code:
D414
TGA Status:
Replaced
DTWD Status:
Replaced
National Endorsed, State Implementation and Classification
Field of Education
0403 - Building
Original TGA Release Date
08/11/2011
Approved Date
11/10/2011
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
C
Nominal Hours
639
Duration
2 Semesters
Current Release Number
2.00
Current Release Date
08/11/2011
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
2.00 08/11/2011 Current Approved
Description

This qualification provides a trade outcome in gas fitting.
Occupational titles may include:
Gas fitter.
The qualification has core and elective unit of competency requirements that cover some common skills for the plumbing industry, as well as gas fitting specialist units of competency.
The plumbing industry strongly affirms that training and assessment leading to recognition of skills must be undertaken in a real or very closely simulated workplace environment and this qualification requires all units of competency to be delivered in this context.
Completion of the general induction training program specified by the National Code of Practice for Induction Training for Construction Work (ASCC 2007) is required before entering a construction work site. Achievement of unit CPCCOHS1001A covers this requirement.

Schedule
Packaging Rules
To achieve this qualification, the candidate must demonstrate competency in:
32 units of competency:
- 26 core units
- 6 elective units.

Note: In Western Australia the regulator requires the following:

Restricted Permit Class G
The Certificate III in Gas Fitting (CPC32711) including the following units:
- CPCPCM2021A Work effectively in the plumbing and services sector
- CPCPCM2023A Carry out OHS requirements
- CPCPCM2026A Use plumbing hand and power tools
- CPCPCM2032A Weld using oxy-acetylene equipment

Unrestricted Permit Class G Installation
The Certificate III in Gas Fitting (CPC32711) including the following units:
- CPCPCM2021A Work effectively in the plumbing and services sector
- CPCPCM2023A Carry out OHS requirements
- CPCPCM2026A Use plumbing hand and power tools
- CPCPCM2032A Weld using oxy-acetylene equipment
- CPCPCM3012A Weld plastic pipe using fusion method
- CPCPGS3025A Install subsidiary gas meters
- CPCPGS4011A Design and size consumer gas installations
1. Core Units

All twenty six (26) units must be completed

State Code National Code Title Hours Type
W9636 CPCPCM2011A Apply first aid in the workplace 24 Unit of competency
D7461 CPCPGS3024A Calculate and install natural ventilation for Type A gas appliances 12 Unit of competency
W9627 CPCPCM2002A Carry out interactive workplace communication 12 Unit of competency
D7409 CPCPCM2027A Carry out levelling 12 Unit of competency
D7406 CPCPCM2023A Carry out OHS requirements 34 Unit of competency
D7410 CPCPCM2028A Cut and join sheet metal 16 Unit of competency
D7460 CPCPGS3023A Disconnect and reconnect Type A gas appliances 16 Unit of competency
D7417 CPCPCM3011A Flash penetrations through roofs and walls 30 Unit of competency
D7407 CPCPCM2025A Handle and store plumbing materials 12 Unit of competency
D9305 CPCPGS3033A Install and Commission Type A gas appliances 24 Unit of competency
D7454 CPCPGS3017A Install gas detection devices 4 Unit of competency
D9303 CPCPGS3031A Install gas piping systems 24 Unit of competency
D7455 CPCPGS3018A Install gas pressure control equipment 12 Unit of competency
D9306 CPCPGS3034A Install LPG storage of aggregate storage capacity up to 500 litres 12 Unit of competency
D7453 CPCPGS3016A Install LPG systems in caravans, mobile homes, water craft and mobile workplaces 20 Unit of competency
D7456 CPCPGS3019A Install Type A gas appliance flues 10 Unit of competency
D7459 CPCPGS3022A Maintain Type A gas appliances 8 Unit of competency
D7412 CPCPCM2030A Mark out materials 16 Unit of competency
D7458 CPCPGS3021A Purge consumer piping 6 Unit of competency
W9629 CPCPCM2004A Read plans and calculate plumbing quantities 12 Unit of competency
D9304 CPCPGS3032A Size consumer gas piping systems 12 Unit of competency
D7408 CPCPCM2026A Use plumbing hand and power tools 16 Unit of competency
D7414 CPCPCM2033A Weld using arc welding equipment 8 Unit of competency
D7413 CPCPCM2032A Weld using oxy-acetylene equipment 8 Unit of competency
D7405 CPCPCM2021A Work effectively in the plumbing and services sector 16 Unit of competency
D7416 CPCPCM2035A Work safely on roofs 15 Unit of competency
2. Elective Units

Six (6) units to be completed
The following outlines ONE example of a training program for this qualification. Please refer to the Training Package for the full list of available options

State Code National Code Title Hours Type
D7411 CPCPCM2029A Cut using oxy-LPG-acetylene equipment 8 Unit of competency
D7514 CPCPCM3013A Fabricate and install non-ferrous pressure piping 8 Unit of competency
D7469 CPCPMS3011A Fabricate and install steel pressure piping 52 Unit of competency
D7462 CPCPGS3025A Install subsidiary gas meters 6 Unit of competency
D7354 CPCCCM3001B Operate elevated work platforms 16 Unit of competency
D7419 CPCPCM3012A Weld plastic pipe using fusion method 8 Unit of competency
3. WA Required Units

Please Note:
For Class G Permit - Installation Only, the following units MUST be completed:
- CPCPCM3012A Weld plastic pipe using fusion method
- CPCPGS3025A Install subsidiary gas meters
- CPCPGS4011A Design and size consumer gas installations
and
For unrestricted Class G Permit - Installation and Servicing, the following units MUST be completed:
- CPCPCM3012A Weld plastic pipe using fusion method
- CPCPGS3025A Install subsidiary gas meters
- CPCPGS4011A Design and size consumer gas installations
- CPCPGS4012A Service Type A Gas Appliances

State Code National Code Title Hours Type
D7463 CPCPGS4011A Design and size consumer gas installations 38 Unit of competency
D7464 CPCPGS4012A Service Type A gas appliances 150 Unit of competency
Replaces
State Code National Code Title Type
W603 CPC32708 Certificate III in Gas Fitting Qualification
Replaced By
State Code National Code Title Type
J494 CPC32712 Certificate III in Gas Fitting Qualification
VET Info Notes
This training program is a representation of the qualification code CPC32711 taken from the Construction, Plumbing and Services Training Package CPC08 V6 which should be consulted for a full description of requirements.

1. This qualification is the copyright of DEEWR.

2. Further information on this qualification is contained in the training Package available on the national training website at training.gov.au.

3. This model training program was entered on to STARS on 11/10/2011.
Entry Requirements

Not Applicable

Traineeships and Apprenticeships
No information