Unit of competency Outline

Date retreived
22/07/2026 4:43 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Monitor contained waste

Monitor contained waste

Unit of competency
National Code
CPPWMT3025A
State Code
WC192
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
10/01/2012
State Implementation and Classification
Approved Date
06/07/2012
Field of Education
039901 - Environmental Engineering
Original Release Date
06/07/2012
Nominal Hours
40
Description
This unit of competency specifies the outcomes required to monitor waste containment and storage. Waste types will generally be regulated (prescribed) solid and liquid wastes. The unit requires the ability to monitor activity according to schedule and apply safe work practices.
Notes
Elements and Performance Criteria
1 Organise for monitoring of contained waste.
  • 1.1 Contained waste monitoring requirements are identified according to waste type, length of storage, organisational requirements, manufacturer specifications and legislation and codes.
  • 1.2 Monitoring equipment is selected, according to organisational and contained waste monitoring requirements.
  • 1.3 Potential hazards and risks of job requirements are identified according to organisational requirements, and occupational health and safety (OHS) regulations and other legislation and codes.
  • 1.4 Emergency and personal protective equipment (PPE) is selected and fitted according to job and organisational requirements, and manufacturer specifications.
2 Check waste containment.
  • 2.1 Integrity of waste containment is checked to ensure no leakage of waste.
  • 2.2 Stocktake of waste is conducted to confirm recorded stock levels.
  • 2.3 Testing of waste containment is organised according to manufacturer specifications, organisational requirements and legislation.
3 Check storage facility and report monitoring activities.
  • 3.1 Storage facility is checked to ensure no contamination in the area according to organisational requirements and legislation and codes.
  • 3.2 Storage facility is secured according to organisational requirements and legislation and codes to prevent unauthorised access.
  • 3.3 Testing of waste storage facility is organised according to organisational requirements.
  • 3.4 Report of contained waste monitoring is completed promptly and according to organisational requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Contained waste monitoring requirements may include:
checks for integrity of containment
compliance with legislative requirements
sampling
security of storage facility and testing.
Waste types may include:
solid (non-hazardous), e.g. construction and demolition
liquid (non-hazardous), e.g. chemical and aqueous
hazardous - regulated, prescribed, quarantined, medical and clinical
recoverable resources, e.g. recyclable and green waste.
Organisation may include:
all forms of business enterprises
local government and councils.
Organisational requirements may include information found in:
briefing papers
job sheets
letters
memos
operations manuals
quality assurance documents
tender and contract documents
verbal or written instructions
work procedures.
Manufacturer specifications are found in:
equipment specifications
instruction leaflets
operator manuals.
Legislation and codes may include:
codes, including:
Australian Code for the Transport of Dangerous Goods by Road and Rail
industry
commonwealth, state and territory legislation, including:
anti-discrimination
environmental protection
equal employment opportunity
freedom of information
industrial
OHS
trade practices
road laws.
Monitoring equipment may include:
sampling equipment
testing equipment.
Potential hazards and risks are those identified by the organisation that may lead to:
damage to plant, vehicle or property
harm to the environment
illness or injury to employees, contractors or the public
injuries resulting from manual handling and repetitive work.
Hazards and risks may include:
broken glass
broken metal
compaction equipment
contamination
dust
fire
gases and fumes
hazardous waste (e.g. sharps)
narrow driveways
other vehicles and equipment
overhanging signs
projectiles
spark-producing equipment
unguarded conveyor belts
weather.
Emergency and personal protective equipment must include:
communications equipment
eye protection, such as goggles and protective glasses
eyewash kit
fire extinguishers
first aid kit
footwear
gloves
overalls and protective clothing.
Emergency and personal protective equipment could also include:
breathing apparatus
emergency procedure guides
face shields or masks
hard hats
hearing protection
MSDS
spill kit.
Personal protective equipmentmust be:
cleaned and fitted according to organisational requirements, manufacturer specifications and OHS requirements
worn when required according to organisational requirements
stored according to organisational requirements.
Integrity of waste containment should include checks for:
contamination
drum expansion
gases
leaching
leaks
seals
spillage
unstable form.
Testing may include visual checks on:
contamination
gases
humidity
leaks
litter
pressure
temperature.
Storage facility may include:
may include:
bunded area
bunkers
containers
pits
stockpiles
tanks
trucks
under awning
warehouse
may be located at:
materials recovery facility
treatment site
waste generator site.
Contamination may include:
exposure to sunlight
infestation
mixing with other waste types
rot or mould
waterlogging.
Report may include:
checks completed
defects identified
faults serviced
housekeeping undertaken
materials used
parts replaced
repairs and adjustments made.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed by observation of practical demonstration in the workplace or in a simulated environment.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of the required skills and knowledge specified in this unit.
In particular the person should demonstrate the ability to:
determine contained waste monitoring requirements
determine monitoring equipment requirements
identify potential hazards and risks to waste containment
organise stockpile of waste cover material
observe OHS requirements.
Context of and specific resources for assessment
Assessment of essential underpinning knowledge may be conducted in an off-site context. It is to comply with relevant regulatory or Australian standards’ requirements.
Resource implications for assessment include:
work plans and approved specifications
forms and procedures manuals.
Method of assessment
Monitoring contained waste must comply with industry expectations in the particular client environment. If the environment is narrowly defined or is not representative of industry needs, it may be necessary to refer to portfolio case studies to assess competency in the monitoring of contained waste.
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Property Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Guidance information for assessment
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
This unit could be assessed on its own or in combination with other units relevant to the job function, for example:
CPPCMN3001B Participate in environmentally sustainable work practices
CPPCMN3003A Contribute to workplace safety arrangements
CPPWMT3020A Place and compact waste.
Replaces
State Code National Code Title Type
S4390 PRMWM25B Monitor contained waste Unit of competency
Replaced By
State Code National Code Title Type
AXI45 CPPWMT3025 Monitor contained waste Unit of competency
OBO63 CPPWMT3008 Store and monitor contained waste Unit of competency
State Code National Code Title Type
D764 CPP30711 Certificate III in Waste Management Qualification