Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Diagnose and rectify faults in servo drive systems

Diagnose and rectify faults in servo drive systems

Unit of competency
National Code
UEEIC0019
State Code
OCB11
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031307 - Communications Technologies
Original Release Date
12/07/2021
Nominal Hours
54
Description
This unit involves the skills and knowledge required to diagnose and rectify faults in system controlling servo drive systems.It includes applying safe working practices; interpreting technical data; applying knowledge of servo/stepper drives operating parameters to logical fault-finding processes; implementing fault rectification, safety and functional testing; and reporting work activities and outcomes.The skills and knowledge described in this unit require a licence or permit to practice in the workplace where work is carried out on electrical installations which are designed to operate at voltages greater than 50 volt (V) alternating current (a.c.) or 120 V direct current (d.c.).Competency development activities in this unit are subject to regulations directly related to licensing. Where a licence or permit to practice is not held, skills and knowledge described in this unit require a relevant contract of training, such as an Australian Apprenticeship. Additional and/or other conditions may apply in some jurisdictions subject to regulations related to electrical work. Practice in the workplace and during training is also subject to work health and safety (WHS)/occupational health and safety (OHS) regulations.Permits may also be required for some work environments, such as confined spaces, working aloft, near live electrical apparatus and site rehabilitation.No other licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to diagnose and rectify servo drive system faults
  • 1.1 WHS/OHS processes and workplace procedures for a given work area are identified, obtained and applied
  • 1.2 Hazards are identified, WHS/OHS risks assessed, and control measures and workplace procedures are implemented in preparation for work
  • 1.3 Safety hazards that have not previously been identified are documented and risk control measures devised and implemented in consultation with relevant person/s
  • 1.4 Scope of fault/s is determined from fault report/s, relevant documentation and in consultation with relevant person/s
  • 1.5 Relevant person/s is consulted to ensure work is coordinated effectively with others involved on the worksite
  • 1.6 Tools, equipment and testing devices needed to diagnose faults are obtained in accordance with workplace procedures and checked for correct operation and safety
2 Diagnose and rectifyservo drive system fault/s
  • 2.1 WHS/OHS risk control measures and workplace procedures for carrying out work are followed
  • 2.2 Need to inspect, test or measure live work is determined and conducted in accordance with WHS/OHS requirements and workplace procedures, as required
  • 2.3 Circuits/machines/plant are inspected, checked and isolated, as required, in accordance with WHS/OHS requirements and workplace procedures
  • 2.4 Logical diagnostic methods/techniques are applied to diagnose servo/stepper drive control system faults employing measurements and estimations of system operating parameters referenced to system operational requirements
  • 2.5 Fault scenarios are tested and confirmed as being the source of system problems in accordance with workplace procedures
  • 2.6 Cause of the fault/s is identified and relevant person/s identified to rectify the fault/s, as required, outside the scope of the servo/stepper drive control system
  • 2.7 Faults in the control components of the system are rectified in accordance with servo drive control system operation standard
  • 2.8 System is inspected and tested to verify that the system operates as intended and to specified requirements
  • 2.9 Decisions for dealing with unplanned situations are determined from discussions with relevant person/s, job specifications and requirements
  • 2.10 Methods for dealing with unplanned situations are selected on the basis of safety and specified work outcomes
  • 2.11 Diagnosis and rectification activities are carried out efficiently, without unnecessary waste of materials or damage to apparatus, the surrounding environment or services using sustainable energy practices
3 Complete and report fault diagnosis and rectification activities
  • 3.1 WHS/OHS work completion risk control measures and workplace procedures are followed
  • 3.2 Worksite is made safe in accordance with workplace safety procedures
  • 3.3 Rectification of faults is documented in accordance with workplace procedures
  • 3.4 Relevant person/s is notified in accordance with workplace procedures that the system fault/s has been rectified