Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Depower and reinitialise battery electric vehicles
Depower and reinitialise battery electric vehicles
Unit of competency
National Code
AURETH101
AURETH101
State Code
OCK26
OCK26
TGA Status
Current
Current
DTWD Status
Approved
Approved
State Implementation and Classification
Approved Date
31/03/2021
Field of Education
030505 - Automotive Electrics And Electronics
Original Release Date
31/03/2021
Nominal Hours
10
Description
This unit describes the skills and knowledge required to depower and reinitialise battery electric vehicles (BEVs). It involves ensuring the vehicle high voltage (HV) rechargeable energy storage system (RESS) is isolated before commencing any service or repair work. It also involves calibrating vehicle systems that may need resetting once the energy storage system is reinitialised. Importance is placed in the unit on applying RESS and separated extra low voltage (SELV) electrical safety procedures.The unit applies to those who work in the automotive service and repair industry. No licensing, legislative, regulatory or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1. Prepare to depower and reinitialise BEV
- 1.1 Identify job requirements from workplace instructions
- 1.2 Identify required information for servicing activity
- 1.3 Identify hazards associated with the work, assess potential risks and implement control measures in line with workplace policies and procedures
- 1.4 Identify tools and equipment required for servicing activity and establish serviceability according to workplace procedures
2. Deactivate vehicle RESS
- 2.1 Locate and disconnect SELV supply according to manufacturer specifications
- 2.2 Locate and remove RESS service plug or manual service disconnect to depower vehicle HV RESS according to manufacturer specifications
- 2.3 Stabilise vehicle is stabilised ensure zero residual voltage according to manufacturer procedures
- 2.4 Secure and retain RESS service plug or manual service disconnect to prevent refitting by third party
3. Reinitialise vehicle RESS
- 3.1 Reconnect SELV and RESS service plug or manual service disconnect in the correct order and reactivate vehicle
- 3.2 Carry out diagnostic tests to ensure correct recalibration of subsystems affected by depower process according to manufacturer procedures
- 3.3 Check RESS and vehicle subsystems for correct operation
- 3.4 Report post-reactivation faults according to workplace procedures
4. Complete work processes
- 4.1 Conduct final inspection according to workplace procedures and confirm vehicle is ready for use
- 4.2 Clear work area and dispose of or recycle materials according to workplace procedures
- 4.3 Complete documentation according to workplace procedures