Unit of competency Outline

Date retreived
23/07/2026 1:29 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Joint and terminate coaxial cable

Joint and terminate coaxial cable

Unit of competency
National Code
ICTCBL2066A
State Code
D3306
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
15/06/2010
State Implementation and Classification
Approved Date
06/01/2011
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
06/01/2011
Nominal Hours
60
Description
This unit describes the performance outcomes, skills and knowledge required to install, joint and terminate coaxial cable on customer premises.Coaxial cables are used in all telecommunications applications including convergence technologies of telephony, data, video and multimedia as part of Next Generation Networks (NGN).No licensing, legislative, regulatory or certification requirements apply to this unit at the time of endorsement but users should confirm requirements with the relevant federal, state or territory authority.
Notes
Elements and Performance Criteria
1. Prepare to install and joint coaxial cable
  • 1.1. Confirm approval for site access with customer prior to site entry and comply with site security arrangements and relevant legislation, codes, regulations and standards
  • 1.2. Read and interpret customer's installation specifications and physical conditions at site to determine layout of job
  • 1.3. Locate and identify adjoining other services according to enterprise guidelines and occupational health and safety (OHS) practices
  • 1.4. Test for presence of dangerous gases in underground enclosures according to enterprise guidelines
  • 1.5. Undertake approved alterations to the design according to enterprise guidelines
2. Verify placement and secure coaxial cable
  • 2.1. Use safety equipment to protect self and public according to enterprise guidelines and OHS
  • 2.2. Maintain coaxial cable segregation to industry standard requirements
  • 2.3. Protect integrity of the coaxial shield cable to ensure no loss of performance
  • 2.4. Place cable in position with sufficient slack to allow termination and maintain minimum bend radius according to manufacturer's specifications
  • 2.5. Follow installation designs to install cable safely without damage to cable or customer's premises
  • 2.6. Maintain radio frequency (RF) signal strength by installing cable lengths within manufacturer's or design specifications
  • 2.7. Locate securing hardware to reduce the cumulative effect on cable wave shape properties and attach cable ties to minimise cable damage
3. Joint coaxial cable
  • 3.1. Strip coaxial cable according to specifications to required length using appropriate tools
  • 3.2. Select appropriate kit to match the type of coaxial cable in use and the jointing method according to manufacturer's recommendations
  • 3.3. Joint cable and ensure jointing fitting retains the segregation of conductor and shield
  • 3.4. Seal all joints according to manufacturer's specifications
4. Terminate coaxial cable
  • 4.1. Prepare coaxial cable for termination according to specifications using appropriate tool
  • 4.2. Select connectors to match the type of coaxial cable in use and use terminating method recommended by manufacturer
  • 4.3. Verify connector fitting retains the segregation of conductor and shield
  • 4.4. Terminate connectors to torque as recommended by manufacturer to prevent radio frequency leakage
  • 4.5. Test connectors to mating specifications using gauge tester
  • 4.6. Maintain a continuous ground on the terminations and waterproof seal to preserve cable integrity
5. Complete splicing operation
  • 5.1. Place cables in enclosure and lay up according to manufacturer's instructions and enterprise guidelines and check that no safety hazards are evident
  • 5.2. Place other services according to enterprise guidelines
  • 5.3. Reinstate site and remove waste and debris for disposal according to environmental requirements and to maintain safe worksite conditions
6. Complete installation administration
  • 6.1. Complete reports according to enterprise policy
  • 6.2. Note alterations to plans using appropriate symbols
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Site security arrangements may include:
access times and methods
approval to enter site
approved entry requirements
electronic surveillance
security clearance.
Relevant legislation, codes, regulations and standards may include:
Australian Communications Industry Forum (ACIF) standards and codes
Australian Communications and Media Authority (ACMA) technical standards
ARPANSA electromagnetic radiation (EMR) standard
AS Communications Cabling Manual (CCM) Volume 1
AS/NZS 3000:2007
AS/NZS 3080:2003
AS/NZS 3084:2003
AS/NZS 3085.1:2004
AS/NZS IEC 61935.1:2006
AS/NZS IEC 61935.2:2006
AS/NZS ISO/IEC 14763.3:2007
AS/NZS ISO/IEC 15018:2005
AS/NZS ISO/IEC 24702:2007
Australian building codes and regulations
cabling security codes and regulations
confined spaces regulations
enterprise standards
environmental protection
equipment standards
fire regulations
heritage legislation
international standards
intrinsically safe lightning protection
local government
mining legislation
noise abatement and heritage legislation
OHS
Radcoms Act
regulated or industry codes of practice
site engineering standard
technical standards AS/ACIF S008:2006 and AS/ACIF S009:2006
Telecoms Act
WIs, CIs, Business Operating Procedures (BOP), Radiocommunications Assignment and Licensing Instruction (RALI), assignment guidelines, spectrum planning reports.
Customer's installation specifications may include:
cable plans and designs
contract documents
specification schedules.
Other services may include:
availability and suitability of existing cabling trays and fixing systems
fire sprinkler systems
gas and water mains
high voltage (HV) power.
OHS may include:
safe use and handling of:
chemicals
materials
tools and equipment
work platforms.
Coaxial cable may be:
aerial or underground
flexible:
external
internal
flooded coaxial for underground use
hard line:
external
internal
powered or unpowered
RG6 and RG11 quad shield.
Manufacturer's specifications may include:
electrical characteristics:
isolation voltage
voltage requirements
handling instructions
installation instructions
performance characteristics
frequency response
impedance
loss
testing details.
Tools may include:
hand or power tools:
connector gauges
coring
crimping
stripping and preparation tool
torque spanner.
Connectors may include:
integral pin
internal or external
pin type
separate pin.















EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment

Critical aspects for assessment and evidence required to demonstrate competency in this unit
Evidence of the ability to:
joint and terminate coaxial cable using specialised hand or power tools and equipment
apply related OHS requirements and work practices
conduct signal strength tests and interpret results.
Context of, and specific resources for assessment
Assessment must ensure:
sites where jointing metallic conductor cable may be conducted
use of joint testing equipment currently used in industry
relevant regulatory and equipment documentation that impact on cable jointing and testing activities.
Methods of assessment
A range of assessment methods should be used to assess practical skills and knowledge. The following examples are appropriate for this unit:
review of hands-on project completed by the candidate
review of oral and written report with test results
direct observation of the candidate jointing and terminating cables and testing joints.
Guidance information for assessment
Holistic assessment with other units relevant to the industry sector, workplace and job role is recommended, for example:
ICTCBL2005A Install customer cable support systems
ICTCBL2006A Place and secure customer cable.

Aboriginal people and other people from a non-English speaking background may have second language issues.

Access must be provided to appropriate learning and assessment support when required.

Assessment processes and techniques must be culturally appropriate, and appropriate to the oral communication skill level, and language and literacy capacity of the candidate and the work being performed.

In all cases where practical assessment is used it will be combined with targeted questioning to assess required knowledge. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency.

Where applicable, physical resources should include equipment modified for people with special needs.




Replaces
State Code National Code Title Type
D2118 ICTTC066D Joint and terminate coaxial cable Unit of competency
Replaced By
State Code National Code Title Type
AWG40 ICTCBL209 Joint and terminate coaxial cable Unit of competency
WI875 ICTCBL2066B Joint and terminate coaxial cable Unit of competency