Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Operate and control surface finishing waste treatment process

Operate and control surface finishing waste treatment process

Unit of competency
National Code
MEM08008B
State Code
W5407
TGA Status
Replaced
DTWD Status
Transition (Replaced)
Current Release Number
1.00
Current Release Date
01/12/2005
State Implementation and Classification
Approved Date
18/06/2009
Field of Education
039901 - Environmental Engineering
Original Release Date
18/06/2009
Nominal Hours
27
Description
This unit covers treating metal finishing effluent waters
Notes
Elements and Performance Criteria
1. Load waste product
  • 1.1. Waste from production process is obtained via established procedures.
  • 1.2. Waste is loaded in accordance with standard operating procedures for waste/effluent.
2. Monitor plant for waste by-products
  • 2.1. All process parameters are accurately monitored and recorded to identify waste/effluent.
  • 2.2. Recording devices are checked for correct/continuous operation.
3. Adjust process
  • 3.1. Knowledge of waste treatment processes is applied in determining appropriate adjustments.
  • 3.2. Process parameters are checked to ensure they remain within specified limits.
  • 3.3. All adjustments are made to accord with authority requirements with regard to waste.
  • 3.4. In the event of mechanical failure, appropriate corrective action is undertaken.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Waste/effluent
Rinse waters, spent solutions, spills, leaks
Recording devices
pH meter, oxidising/reduction/potential probes (redox), flow rate
Waste treatment processes
Neutralisation, metal precipitation, solid separation (gravity, centrifuging), oxidation, reduction, grease entrapment, ion exchange
Process parameters
Solution flow, pH, redox (oxidising /reduction/potential) which typically contain cyanides, hexavalent chromium, heavy metal cations, certain anions, greases, etc.
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to treat metal finishing effluent waters. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with metal finishing waste effluent treatment or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.