Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Commission domestic and residential fire suppression sprinkler systems
Commission domestic and residential fire suppression sprinkler systems
Unit of competency
National Code
CPCPFS4021A
CPCPFS4021A
State Code
WF978
WF978
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
22/03/2013
Field of Education
039905 - Fire Technology
Original Release Date
22/03/2013
Nominal Hours
52
Description
This unit of competency specifies the outcomes required to test and commission domestic and residential fire suppression sprinkler systems in buildings up to four storeys in height.It covers preparation for the work, identification and confirmation of system specifications and requirements, physical testing and commissioning of the systems, and work finalisation processes including records and documentation.
Notes
Elements and Performance Criteria
1 Prepare for work.
- 1.1 Plans and specifications are obtained.
- 1.2 Work health and safety (WHS) andenvironmental requirements associated with commissioning domestic and residential fire suppression sprinkler systems are adhered to throughout the work.
- 1.3 Quality assurance requirements are identified and adhered to according to workplace requirements.
- 1.4 Tasks are planned and sequenced in conjunction with others involved in or affected by the work.
- 1.5 Tools, equipmentand materials for commissioning domestic and residential fire suppression sprinkler systems, including personal protective equipment, are selected and checked for serviceability.
- 1.6 Work area is prepared to support efficient commissioning process.
2 Identify system requirements.
- 2.1 System design requirements are identified and confirmed from job specifications and according to standards.
- 2.2 Commissioning requirements for domestic and residential fire suppression sprinkler systems are identified according to standards, authorities' requirements and job specifications.
3 Test and commission system.
- 3.1 Sprinkler systems are checked to ensure type and installation conform to standards, job specifications, manufacturer recommendations and authorities' requirements.
- 3.2 Operation of system is tested according to job specifications, manufacturer recommendations and authorities' requirements and is adjusted as required.
- 3.3 System is commissioned and maintained to ensure correct operation according to standards, and manufacturer and job specifications.
- 3.4 Sustainability principles and concepts are observed when preparing for and undertaking work process.
4 Clean up work area.
- 4.1 Work area is cleared and materials disposed of, reused or recycled according to legislation, regulations, codes of practice and job specification.
- 4.2 Tools and equipment are cleaned, checked, maintained and stored according to manufacturer recommendations and workplace procedures.
- 4.3 Informationis accessed and documentation completed according to workplace requirements.
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
hand and power tools
test equipment.
Materials may include:
actuating devices
alarms
control valve assemblies
unplasticised polyvinyl chloride (PVC-U), steel or copper pipes and other approved materials
sprinkler heads.
Domestic and residential fire suppression sprinkler systems may include:
actuating devices
alarms
control valve assemblies
piping
sprinkler heads.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include efficient water usage, harvesting and/or disposal.
Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing regulations
relevant Australian standards, including AS2118 Automatic fire sprinkler systems
safe work procedures relating to testing and commissioning domestic and residential fire suppression sprinkler systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
Work health and safety is to be according to commonwealth, state and territory legislation and regulations and may include:
handling of materials
hazard control
personal protective clothing and equipment prescribed under legislation, regulations and workplace policies and practices
safe operating procedures, including recognising and preventing hazards associated with:
electricity
hazardous materials and substances
other machines
surrounding structure and facilities
trip hazards
underground services
use of tools and equipment
work site visitors and the public
working at heights
working in confined spaces
working in proximity to others
use of firefighting equipment
use of first aid equipment
workplace environment and safety.
Environmental requirements cover water quality management and may include:
clean-up protection
stormwater protection
waste management.
Quality assurance requirements may include:
Australian standards
Environment Protection Authority (EPA)
internal company quality assurance policy and risk management strategy
International Standards Organisation
site safety plan
workplace operations and procedures.
Tools and equipment may include:
hand and power tools
test equipment.
Materials may include:
actuating devices
alarms
control valve assemblies
unplasticised polyvinyl chloride (PVC-U), steel or copper pipes and other approved materials
sprinkler heads.
Domestic and residential fire suppression sprinkler systems may include:
actuating devices
alarms
control valve assemblies
piping
sprinkler heads.
Sustainability principles and concepts:
cover the current and future social, economic and environmental use of resources
may include efficient water usage, harvesting and/or disposal.
Information may include:
charts and hand drawings
instructions issued by authorised organisational or external personnel
job drawings
manufacturer specifications and instructions
material safety data sheets (MSDS)
memos
organisation work specifications and requirements
plans and sketches
regulatory and legislative requirements, particularly those pertaining to:
building codes
WHS and environmental requirements
plumbing regulations
relevant Australian standards, including AS2118 Automatic fire sprinkler systems
safe work procedures relating to testing and commissioning domestic and residential fire suppression sprinkler systems
signage
verbal, written and graphical instructions
work bulletins
work schedules, plans and specifications.
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to testing and commissioning domestic and residential fire suppression sprinkler systems
applying safety requirements throughout the work sequence, including electrical safety requirements and the use of personal protective clothing and equipment
testing and commissioning a fire suppression sprinkler system for a residential complex containing a minimum of a communal catering and living area and multiple residential quarters (or equivalent) and a fire suppression sprinkler system for a domestic residence containing a minimum of two rooms, ensuring:
application of sustainability principles and concepts
correct identification of location, design specification and details of proposed service
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, standards and organisational quality procedures and processes
where at least one of the systems is for a complex of not less than three storeys
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Overview of assessment
This unit of competency could be assessed in the workplace or a close simulation of the workplace environment providing that simulated or project-based assessment techniques fully replicate plumbing and services workplace conditions, materials, activities, responsibilities and procedures.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
A person who demonstrates competency in this unit must be able to provide evidence of:
locating, interpreting and applying relevant information, standards and specifications to testing and commissioning domestic and residential fire suppression sprinkler systems
applying safety requirements throughout the work sequence, including electrical safety requirements and the use of personal protective clothing and equipment
testing and commissioning a fire suppression sprinkler system for a residential complex containing a minimum of a communal catering and living area and multiple residential quarters (or equivalent) and a fire suppression sprinkler system for a domestic residence containing a minimum of two rooms, ensuring:
application of sustainability principles and concepts
correct identification of location, design specification and details of proposed service
correct selection and use of appropriate processes, tools and equipment
completion of all work to specification
compliance with regulations, standards and organisational quality procedures and processes
where at least one of the systems is for a complex of not less than three storeys
communicating and working effectively and safely with others.
Context of and specific resources for assessment
This competency is to be assessed using standard and authorised work practices, safety requirements and environmental constraints.
Assessment of essential underpinning knowledge will usually be conducted in an off-site context.
Assessment is to comply with relevant regulatory or Australian standards' requirements.
Resource implications for assessment include:
an induction procedure and requirement
realistic tasks or simulated tasks covering the minimum task requirements
relevant specifications and work instructions
tools and equipment appropriate to applying safe work practices
support materials appropriate to activity
workplace instructions relating to safe work practices and addressing hazards and emergencies
material safety data sheets
research resources, including industry-related systems information.
Reasonable adjustments for people with disabilities must be made to assessment processes where required. This could include access to modified equipment and other physical resources, and the provision of appropriate assessment support.
Method of assessment
Assessment methods must:
satisfy the endorsed Assessment Guidelines of the Construction, Plumbing and Services Training Package
include direct observation of tasks in real or simulated work conditions, with questioning to confirm the ability to consistently identify and correctly interpret the essential underpinning knowledge required for practical application
reinforce the integration of employability skills with workplace tasks and job roles
confirm that competency is verified and able to be transferred to other circumstances and environments.
Validity and sufficiency of evidence requires that:
competency will need to be demonstrated over a period of time reflecting the scope of the role and the practical requirements of the workplace
where the assessment is part of a structured learning experience the evidence collected must relate to a number of performances assessed at different points in time and separated by further learning and practice, with a decision on competency only taken at the point when the assessor has complete confidence in the person's demonstrated ability and applied knowledge
all assessment that is part of a structured learning experience must include a combination of direct, indirect and supplementary evidence.
Assessment processes and techniques should as far as is practical take into account the language, literacy and numeracy capacity of the candidate in relation to the competency being assessed.
Supplementary evidence of competency may be obtained from relevant authenticated documentation from third parties, such as existing supervisors, team leaders or specialist training staff.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| D7449 | CPCPFS4011A | Commission domestic and residential fire suppression sprinkler systems | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OCO13 | CPCPFS4021 | Commission domestic and residential fire suppression sprinkler systems | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J497 | CPC40912 | Certificate IV in Plumbing and Services | Qualification |