Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Modify fluid power control systems

Modify fluid power control systems

Unit of competency
National Code
MEM18053B
State Code
W5599
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
1.00
Current Release Date
01/12/2005
State Implementation and Classification
Approved Date
26/10/2006
Field of Education
030701 - Mechanical Engineering
Original Release Date
26/10/2006
Nominal Hours
54
Description
This unit covers checking and testing software programs, controlling system inputs and outputs, repairing faulty system inputs and outputs, and preparing a service report.
Notes
Elements and Performance Criteria
1. Check/test control software program
  • 1.1. Program steps are checked against manufacturers' and site specifications using schematics, circuit and ladder diagrams.
  • 1.2. Deviations are determined and recorded.
2. Correct or modify control system software/program
  • 2.1. Program deviations are corrected and aligned to specification requirements using standard operating procedures.
  • 2.2. Modifications to program are undertaken to specification requirements using standard operating procedures.
  • 2.3. Modification is recorded to standard operating procedures.
  • 2.4. Modified program is backed up to standard operating procedures.
3. Check/test control system inputs/outputs
  • 3.1. Input/output signals are checked and assessed against operational specifications using correct and appropriate techniques, tools and equipment.
  • 3.2. Faulty signals are identified, repaired and recorded/reported to appropriate personnel.
4. Repair faulty control system input/output
  • 4.1. Faulty signal source is repaired and/or replaced.
  • 4.2. Repaired/replaced signal source is tested for correct operation in system and commissioned in conformance to operational specifications.
5. Prepare service report
  • 5.1. Service report is prepared and completed following standard operating procedure.
  • 5.2. Recommendations for improvement and repeat downtime avoidance analysis are included.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Control system
PCs, programmable controllers, DCS, relay logic (electric-hydraulic-pneumatic) etc.
Modifications
Modifications covered by this unit are changes to fluid power control systems that lead to desired changes in system performance
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to modify fluid power control systems. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both. Where assessment occurs off the job, i.e. the candidate is not in productive work, an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with modifying fluid power control systems or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning should not require language, literacy and numeracy skills beyond those required in this unit. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.