Unit of competency Outline

Date retreived
22/07/2026 9:07 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Modify fluid power control systems

Modify fluid power control systems

Unit of competency
National Code
MEM18053
State Code
OAU64
TGA Status
Current
DTWD Status
Approved
Current Release Number
2.00
Current Release Date
31/03/2021
State Implementation and Classification
Approved Date
Field of Education
030701 - Mechanical Engineering
Original Release Date
Nominal Hours
54
Description
This unit of competency defines the skills and knowledge required to check and test software programs, control system inputs and outputs, repair faulty system inputs and outputs, and prepare a service report.It covers the skills required to alter the control parameters of fluid power control systems by system modification, this includes the ability to assess system performance based on sound working knowledge of established principles, methods and procedures.System specifications are interpreted and understood from data sheets, circuit diagrams and flow diagrams.Where equipment condition monitoring and recording only is required to be performed then unit MEM18010 Perform equipment condition monitoring and recording should also be selected.No licensing, legislative or certification requirements apply to this unit at the time of publication.Band: BUnit Weight: 6
Notes
Elements and Performance Criteria
1 Determine job requirements
  • 1.1 Follow standard operating procedures (SOPs)
  • 1.2 Comply with work health and safety (WHS) requirements at all times
  • 1.3 Use appropriate personal protective equipment (PPE) in accordance with SOPs
  • 1.4 Identify job requirements from specifications, drawings, job sheets or work instructions
2 Check/test control software program
  • 2.1 Check program steps against manufacturers' and site specifications using schematics, circuit and ladder diagrams and determine and record deviations
3 Correct or modify control system software/program
  • 3.1 Correct and align program deviations to specification requirements
  • 3.2 Undertake modifications to program to specification requirements
  • 3.3 Back up and record modified program
4 Check/test control system inputs/outputs
  • 4.1 Check and assess input/output signals against operational specifications using appropriate tools, equipment and techniques
  • 4.2 Identify and repair and record/report faulty signals to appropriate personnel
5 Repair faulty control system input/output
  • 5.1 Repair and/or replace faulty signal source
  • 5.2 Test repaired/replaced signal source for correct operation in system and commission in compliance to operational specifications
6 Prepare service report
  • 6.1 Prepare and complete a service report and include recommendations for improvement and repeat downtime avoidance analysis in accordance with SOPs
No information
No information
Replaces
State Code National Code Title Type
W5599 MEM18053B Modify fluid power control systems Unit of competency
State Code National Code Title Type
BEJ8 MEM40119 Certificate IV in Engineering Qualification