Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Solve problems in single and three phase low voltage circuits
Solve problems in single and three phase low voltage circuits
Unit of competency
National Code
UEENEEG002B
UEENEEG002B
State Code
W7881
W7881
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
24/09/2012
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
24/09/2012
Nominal Hours
72
Description
1) 1.1) DescriptorThis unit covers ascertaining correct operation of single and three phase circuits and solving circuit problems as they apply to servicing, fault finding, installation and compliance work functions. It encompasses safe working practices, multiphase circuit arrangements, issues related to protection, power factor and MEN systems and solutions to circuit problems derived from calculated and measured parameters.
Notes
Elements and Performance Criteria
1 Prepare to solve single and three phase low voltage circuit problems.
- 1.1 OHS procedures for a given work area are identified, obtained and understood.
- 1.2 Established OHS risk control measures and procedures in preparation for the work are followed.
- 1.3 Safety hazards, which have not previously been identified, are noted and established risk control measures are implemented.
- 1.4 The nature of the circuit(s) problem is obtained from documentation or from work supervisor to establish the scope of work to be undertaken.
- 1.5 Advice is sought from the work supervisor to ensure the work is coordinated effectively with others.
- 1.6 Sources of materials that may be required for the work are established in accordance with established procedures.
- 1.7 Tools, equipment and testing devices needed to carry out the work are obtained and checked for correct operation and safety.
2 Solve single and three phase low voltage circuit problems.
- 2.1 OHS risk control measures and procedures for carrying out the work are followed.
- 2.2 The need to test or measure live is determined in strict accordance with OHS requirements and when necessary conducted within established safety procedures.
- 2.3 Circuits/machines/plant are checked as being isolated where necessary in strict accordance OHS requirements and procedures.
- 2.4 Established methods are used to solve circuit problems from measure and calculated values as they apply to single and three-phase low voltage circuit.
- 2.5 Established methods for dealing with unexpected situations are discussed with appropriate person or persons and documented.
- 2.6 Unexpected situations are dealt with safely and with the approval of an authorised person.
- 2.7 Problems are solved without damage to apparatus, circuits, the surrounding environment or services and using sustainable energy practices.
3 Complete work and document problem solving activities.
- 3.1 OHS work completion risk control measures and procedures are followed.
- 3.2 Work site is cleaned and made safe in accordance with established procedures.
- 3.3 Justification for solutions used to solve circuit problems is documented.
- 3.4 Work completion is documented and an appropriate person or persons notified in accordance with established procedures.
No information
No information
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| W6122 | UEENEEG002A | Solve problems in single and three phase low voltage circuits | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| S7319 | UEENEEG102A | Solve problems in low voltage a.c. circuits | Unit of competency |