Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Calibrate measuring equipment
Calibrate measuring equipment
Unit of competency
National Code
MEM12005B
MEM12005B
State Code
W5497
W5497
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
17/06/2014
Field of Education
030715 - Precision Metalworking
Original Release Date
17/06/2014
Nominal Hours
54
Description
This unit covers checking measuring equipment for correct operation, and validating/calibrating precision measuring equipment in accordance with predetermined procedures.
Notes
Elements and Performance Criteria
1. Check equipment for correct operation
- 1.1. Appropriate checks are made of components, leads, fasteners, etc. for wear, loose connections or other faults.
2. Validate/calibrate precision measuring equipment
- 2.1. Calibration of precision measuring equipment is assessed to manufacturers' specifications and/or standard operating procedures.
- 2.2. Equipment is calibrated against appropriate physical standards using correct calibration devices, equipment, techniques using predetermined procedures.
- 2.3. Equipment is recommissioned in accordance with standard operating procedures.
RANGE STATEMENT
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Calibration
To standardise the quantities of a measuring instrument
Physical standards
Reference standards of mass length, time, temperature, pressure, volume, process characteristics etc.
Calibration devices, equipment
Micrometer, vernier caliper, voltmeter, oscilloscope, all types of comparators, jigs and fixtures, templates and patterns etc.
Techniques
In standard operating procedures, manufacturers' manuals
Recommissioned
Sealing, tagging, identification or storage in accordance with standard operating procedures
The range statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the performance criteria, is detailed below. Essential operating conditions that may be present with training and assessment (depending on the work situation, needs of the candidate, accessibility of the item, and local industry and regional contexts) may also be included.
Calibration
To standardise the quantities of a measuring instrument
Physical standards
Reference standards of mass length, time, temperature, pressure, volume, process characteristics etc.
Calibration devices, equipment
Micrometer, vernier caliper, voltmeter, oscilloscope, all types of comparators, jigs and fixtures, templates and patterns etc.
Techniques
In standard operating procedures, manufacturers' manuals
Recommissioned
Sealing, tagging, identification or storage in accordance with standard operating procedures
EVIDENCE GUIDE
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to check equipment for correct operation and validate/calibrate precision measuring equipment. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with calibrating measuring equipment or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
The evidence guide provides advice on assessment and must be read in conjunction with the performance criteria, required skills and knowledge, range statement and the Assessment Guidelines for the Training Package.
Overview of assessment
A person who demonstrates competency in this unit must be able to check equipment for correct operation and validate/calibrate precision measuring equipment. Competency in this unit cannot be claimed until all prerequisites have been satisfied.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Assessors must be satisfied that the candidate can competently and consistently perform all elements of the unit as specified by the criteria, including required knowledge, and be capable of applying the competency in new and different situations and contexts.
Context of and specific resources for assessment
This unit may be assessed on the job, off the job or a combination of both on and off the job. Where assessment occurs off the job, that is the candidate is not in productive work, then an appropriate simulation must be used where the range of conditions reflects realistic workplace situations. The competencies covered by this unit would be demonstrated by an individual working alone or as part of a team. The assessment environment should not disadvantage the candidate.
This unit could be assessed in conjunction with any other units addressing the safety, quality, communication, materials handling, recording and reporting associated with calibrating measuring equipment or other units requiring the exercise of the skills and knowledge covered by this unit.
Method of assessment
Assessors should gather a range of evidence that is valid, sufficient, current and authentic. Evidence can be gathered through a variety of ways including direct observation, supervisor's reports, project work, samples and questioning. Questioning techniques should not require language, literacy and numeracy skills beyond those required in this unit of competency. The candidate must have access to all tools, equipment, materials and documentation required. The candidate must be permitted to refer to any relevant workplace procedures, product and manufacturing specifications, codes, standards, manuals and reference materials.
Guidance information for assessment
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| M0381 | MEM12.5BA | Calibrating measuring equipment | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAV42 | MEM12005 | Calibrate measuring equipment | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| D754 | MEA50511 | Diploma of Aeroskills (Non-Destructive Testing) | Qualification |
| J368 | MEM60112 | Advanced Diploma of Engineering | Qualification |
| W249 | MEM60105 | Advanced Diploma of Engineering | Qualification |
| W245 | MEM40105 | Certificate IV in Engineering | Qualification |
| W247 | MEM50105 | Diploma of Engineering - Advanced Trade | Qualification |
| J367 | MEM50212 | Diploma of Engineering - Technical | Qualification |
| W248 | MEM50205 | Diploma of Engineering - Technical | Qualification |
| W528 | MSA60108 | Advanced Diploma of Manufacturing Technology | Qualification |
| W526 | MSA50108 | Diploma of Manufacturing Technology | Qualification |