Unit of competency Outline

Date retreived
23/07/2026 7:17 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Install and maintain cabling for multiple access to telecommunication services

Install and maintain cabling for multiple access to telecommunication services

Unit of competency
National Code
UEEDV0005
State Code
OBX97
TGA Status
Current
DTWD Status
Approved
Current Release Number
2.00
Current Release Date
14/10/2021
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031309 - Communications Equipment Installation And Maintenance
Original Release Date
12/07/2021
Nominal Hours
72
Description
This unit involves the skills and knowledge required to install and maintain telecommunications cabling in buildings and premises.It includes working to relevant regulations, legislation, codes of practice and industry standards and to Australian Communications and Media Authority’s (ACMA) Telecommunications Cabling Provider Rules; installing multiple telecommunication lines for multiple access to telecommunication services; terminating at telecommunication outlets, termination modules and distributors; testing for compliance and completing cabling documentation.This unit applies to customer cabling terminated on distributors and to the installation, maintenance and modification of indoor, external, underground cabling and customer cabling and may be used to connect devices for a range of applications, including telecommunications phones, data (video and multimedia) and security (alarms and fire protection).Work functions in the occupational areas where this unit may be used are subject to regulatory requirements. Refer to the UEE Electrotechnology Training Package Companion Volume Implementation Guide or the relevant regulator for specific guidance on requirements.
Notes
Elements and Performance Criteria
1 Prepare to install and maintain cabling
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) requirements and workplace procedures for a given work area are identified and applied
  • 1.2 Hazards are identified, risks are assessed and control measures and workplace procedures are implemented
  • 1.3 Nature and location of the work is determined from documentation or relevant person/s to determine scope of work to be undertaken
  • 1.4 Cable routes are planned within the constraints of the building structure and in accordance with relevant regulations, legislation, codes of practice and industry standards
  • 1.5 Earthing requirements are determined in accordance with existing earthing arrangements, where applicable, and cable system, earth upper and lower resistance limitations
  • 1.6 Advice is sought from relevant person/s to ensure work is coordinated effectively with others
  • 1.7 Materials required for the work are obtained in accordance with workplace procedures
  • 1.8 Tools, equipment and testing devices required for the work are obtained and checked for correct operation and safety in accordance with workplace procedures
2 Install and maintain cabling
  • 2.1 WHS/OHS risk control measures and workplace procedures for carrying out the work are followed
  • 2.2 Installed support structure is checked for compliance to ensure cable will not be exposed to damage during installation and general operation
  • 2.3 Catenary supports are secured to building structure and tensioned, as required, to ensure cable weight can be carried in operating conditions, with interference and safety segregation maintained in accordance with relevant regulations, legislation, codes and standards
  • 2.4 Protective earthing of metal work is installed in accordance with job requirements and industry standards
  • 2.5 Cables/wires are installed in accordance with manufacturer application, tension and bending stress requirement specifications
  • 2.6 Sufficient cable excess is allowed at cable ends to facilitate termination in accordance with workplace procedures
  • 2.7 Cable ends terminating at a telecommunication outlet are labelled in accordance with industry standards
  • 2.8 Cable is placed and secured to maintain safety and interference segregation in accordance with legislative and industry standards
  • 2.9 Cable ties are tightened correctly and safely in accordance with workplace procedures and industry standards
  • 2.10 Customer cabling is installed in accordance with relevant regulations, codes of practice and industry standards
  • 2.11 Surge suppression devices are fitted to all cable pairs as required with the devices protectively earthed in accordance with relevant regulations, codes of practice and industry standards
  • 2.12 Telecommunications reference conductor (TRC)/communications earth system (CES)/protective earth (PE) insulation is protected against damage and TRC/CES and PE are segregated in accordance with relevant regulations, codes of practice and industry standards
  • 2.13 Cabling is installed without waste of materials and energy or damage to apparatus, the surrounding environment or services using sustainable energy practices
  • 2.14 Regular quality checks are conducted in accordance with workplace procedures to ensure cabling complies with requirements
3 Terminate, inspect and test cables and earth wires
  • 3.1 WHS/OHS risk control work measures and workplace procedures for carrying out work are followed
  • 3.2 Cable sheath is removed to allow for correct termination length and without damage to underlying conductors and their insulation
  • 3.3 Terminating modules are installed in accordance with manufacturer specifications and cable pairs neatly and sequentially fanned for termination
  • 3.4 Conductors are terminated in accordance with recommended colour code sequence and using relevant termination tools in accordance with manufacturer guidelines and operating instructions
  • 3.5 Cable shields are earthed, as required, in accordance with manufacturer specifications, relevant regulations, codes of practice and industry standards
  • 3.6 Visual inspection is undertaken prior to end-to-end testing of wire and pair termination integrity to confirm termination colour code sequence has been followed
  • 3.7 Cable pairs are tested and clearly labelled to provide accurate identification in accordance with job requirements and workplace procedures
  • 3.8 TRC/CES/PE are terminated with connectors in accordance with manufacturer specifications, relevant industry codes of practice and industry standards
  • 3.9 TRC/CES/PE wire continuity is maintained in accordance with workplace procedures and interface requirements with electrical systems are followed
  • 3.10 TRC/CES/PE installation is tested for continuity insulation resistance and conductive resistance in accordance with relevant industry standards
  • 3.11 Earthing system is labelled in accordance with job requirements and workplace procedures
  • 3.12 New work is tested both in isolation and when integrated with existing systems, and compatibility of alterations with existing systems is confirmed
  • 3.13 Cabling is terminated without waste of materials and energy or damage to apparatus, the surrounding environment or services
  • 3.14 Regular quality checks are conducted and any defects rectified to ensure cabling complies with requirements
4 Complete cabling work records and reporting
  • 4.1 WHS/OHS risk control measures and procedures for work completion are followed
  • 4.2 Worksite is cleaned and made safe in accordance with workplace procedures
  • 4.3 Record sheets, plans of cable location type and infrastructure are accurately created or updated and stored in accordance with customer requirements and workplace procedures
  • 4.4 Cable pair record books are created or updated to provide an accurate record of pair locations, inter-connections and usage in accordance with relevant regulations, codes of practice and industry standards
  • 4.5 Telecommunications cabling advice (TCA 1) is documented and reported in accordance with requirements and workplace procedures
No information
No information
Replaces
State Code National Code Title Type
WC458 UEENEEF102A Install and maintain cabling for multiple access to telecommunication services Unit of competency
State Code National Code Title Type
BFL8 UEE40120 Certificate IV in Computer Systems Qualification
BFQ6 UEE50120 Diploma of Computer Systems Engineering Qualification
BIV4 UEE50122 Diploma of Computer Systems Engineering Qualification
BFM1 UEE60420 Advanced Diploma of Computer Systems Engineering Qualification
BNY4 UEE30225 Certificate III in Computer Systems Equipment Qualification
BFK0 UEE30220 Certificate III in Computer Systems Equipment Qualification
BFM0 UEE30320 Certificate III in Custom Electronics Installations Qualification
BFM9 UEE30420 Certificate III in Data and Voice Communications Qualification
BNZ7 UEE30425 Certificate III in Data and Voice Communications Qualification
BFK1 UEE20720 Certificate II in Data and Voice Communications Qualification
AE230 UEESS00131 Data Communications - ACMA 'Open' Cabling Provider Skill Set Skill set
AE257 UEESS00134 Data Communications - Install Aerial Communication Cables Skill Set Skill set
AE271 UEESS00169 Data Communications - Install and Modify Performance Data Communication Structured Cabling Skill Set Skill set
AE262 UEESS00137 Data Communications - Install Below Ground Communication Cables Skill Set Skill set
BFI9 UEE40220 Certificate IV in Electrical - Data and Voice Communications Qualification
BFM8 UEE62220 Advanced Diploma of Electrical - Engineering Qualification
BFO8 UEE40820 Certificate IV in Electrical - Fire Protection Control Systems Qualification
BIV5 UEE43322 Certificate IV in Electrical - Renewable Energy Qualification
BFK5 UEE50420 Diploma of Electrical Engineering Qualification
BFM2 UEE43020 Certificate IV in Electrical Equipment and Systems Qualification
BFO5 UEE33020 Certificate III in Electrical Fitting Qualification
BFP6 UEE53020 Diploma of Electrical Systems Engineering Qualification
BGT93 52899WA Course in Electrical Trade Licensing Gap Training Accredited course
BFP4 UEE40720 Certificate IV in Electronics and Communications Qualification
BFO7 UEE30920 Certificate III in Electronics and Communications Qualification
BFQ2 UEE60220 Advanced Diploma of Electronics and Communications Engineering Qualification
BFP5 UEE50520 Diploma of Electronics and Communications Engineering Qualification
BFN2 UEE40620 Certificate IV in Electrotechnology - Systems Electrician Qualification
BFN0 UEE30820 Certificate III in Electrotechnology Electrician Qualification
BFM7 UEE43120 Certificate IV in Energy Efficiency and Assessment Qualification
BFL6 UEE41020 Certificate IV in Energy Management and Control Qualification
BOA0 UEE41025 Certificate IV in Energy Management and Control Qualification
BFN3 UEE61820 Advanced Diploma of Engineering Technology - Computer Systems Qualification
BFN8 UEE62120 Advanced Diploma of Engineering Technology - Electrical Qualification
BHZ3 UEE62122 Advanced Diploma of Engineering Technology - Electrical Qualification
BFJ6 UEE61720 Advanced Diploma of Engineering Technology - Electronics Qualification
BHQ0 UEP40322 Certificate IV in ESI Generation Maintenance - Electrical Electronics Qualification
BNY5 UEE31025 Certificate III in Fire Protection Control Qualification
BFO4 UEE31020 Certificate III in Fire Protection Control Qualification
BFK2 UEE40920 Certificate IV in Industrial Electronics and Control Qualification
AE237 UEESS00170 Install and Modify Performance Data Communication Optical Fibre Cabling Skill Set Skill set
BFO3 UEE41720 Certificate IV in Rail - Communications and Network Systems Qualification
BOB2 UEE31425 Certificate III in Security Equipment Qualification
BFL4 UEE31420 Certificate III in Security Equipment Qualification
BFN7 UEE41520 Certificate IV in Video and Audio Systems Qualification