Unit of competency Outline

Date retreived
22/07/2026 10:01 PM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Conduct in-service safety testing of electrical cord connected equipment and cord assemblies

Conduct in-service safety testing of electrical cord connected equipment and cord assemblies

Unit of competency
National Code
UEERL0003
State Code
OBZ38
TGA Status
Current
DTWD Status
Approved
Current Release Number
1.00
Current Release Date
05/10/2020
State Implementation and Classification
Approved Date
12/07/2021
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
12/07/2021
Nominal Hours
18
Description
This unit involves the skills and knowledge required to conduct in-service safety testing of electrical cord connected equipment and cord assemblies.It includes working safely, using portable appliance tester (PAT), identifying faults, applying tagging, arranging for repair of faulty equipment and complete testing documentation.No licensing, legislative or certification requirements apply to this unit at the time of publication.
Notes
Elements and Performance Criteria
1 Prepare to test cord connected apparatus and cord assemblies
  • 1.1 Work health and safety (WHS)/occupational health and safety (OHS) procedures for a given work area are identified, obtained and applied
  • 1.2 WHS/OHS risk control work preparation measures and procedures are followed
  • 1.3 Advice is sought from relevant person/s to ensure work is effectively coordinated with others
  • 1.4 Cord connected apparatus and cord assemblies to be tested are obtained in accordance with workplace procedures
  • 1.5 PAT device is checked for correct operation and safety in accordance with relevant industry standards and workplace procedures
2 Test cord connected apparatus and cord assemblies
  • 2.1 WHS/OHS risk control work measures and procedures are followed
  • 2.2 Measures are followed to ensure that cord connected apparatus and cord assemblies to be tested are not connected to the electrical supply in accordance with relevant industry standards
  • 2.3 Electrical safety requirements and parameters are applied to ensure correct test results are in accordance with relevant industry standards
  • 2.4 Visual inspection and checks of the cord connected apparatus and cord assemblies are carried out in accordance with workplace procedures to detect any abnormal damage or fault
  • 2.5 Approval is obtained in accordance with workplace procedures from relevant person/s before any contingencies are implemented
  • 2.6 PAT routines are followed to test cord connected apparatus and cord assemblies in accordance with workplace procedures
  • 2.7 Unsafe cord connected apparatus and cord assemblies are identified from test results in accordance with workplace procedures
  • 2.8 Testing is undertaken effectively to minimise waste of energy and damage to apparatus
3 Tag cord connected apparatus and cord assemblies and document testing activities
  • 3.1 WHS/OHS work completion risk control measures and procedures are followed
  • 3.2 Worksite is cleaned and made safe in accordance with workplace procedures
  • 3.3 Cord connected apparatus and cord assemblies are tagged in accordance with workplace procedures for their safety status
  • 3.4 Arrangements are made for unsafe cord connected apparatus and cord assemblies to be repaired by relevant person/s
  • 3.5 Safety testing activities are documented in accordance with relevant industry standards and workplace procedures
No information
No information