Unit of competency Outline
Date retreived
22/07/2026 3:41 PM AWST
22/07/2026 3:41 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Assess conservation requirements
Assess conservation requirements
Unit of competency
National Code
MSFSL5001
MSFSL5001
State Code
WI649
WI649
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
20/06/2014
Field of Education
040323 - Glazing
Original Release Date
20/06/2014
Nominal Hours
30
Description
This unit of competency covers assessing leadlight and stained glass panels in order to identify and document their conservation requirements.Licensing, legislative or certification requirements may apply to this unit and relevant state/territory and local government agencies should be consulted to determine any necessary certification or licensing for undertaking glass and glazing work. Access to construction sites requires certification of general induction training specified by the National Code of Practice for Induction for Construction Work (ASCC 2007).
Notes
Elements and Performance Criteria
1 Identify conservation assessment requirements
- 1.1 Applicable work health and safety (WHS), legislative and organisational requirements relevant to leadlight and stained glass operations are verified and complied with
- 1.2 Purpose of the assessment is established, confirmed and clarified with appropriate personnel
- 1.3 Assessment outcomes are identified and confirmed
2 Plan assessment processes
- 2.1 Location of the leadlight and stained glass panels to be assessed is identified and observed
- 2.2 Assessment sequence is identified and a work plan is developed
- 2.3 Tools and equipment required for the assessment are identified
- 2.4 Approval of assessment plan is obtained as required by agreed procedures
3 Prepare for the assessment
- 3.1 Tools and equipment are assembled, positioned and checked prior to use to ensure they are appropriate for the assessment, serviceable and in a safe condition
- 3.2 Plans and other documents are assembled and positioned to allow for confirmation of the panel structure and placement
- 3.3 Photographs are taken of the panel for documentation of condition and for later reference
4 Assess the panel
- 4.1 Glass faults are identified and noted
- 4.2 Structural faults or problems are identified and noted
- 4.3 Environmental effects are identified and noted
- 4.4 Other problems are identified and noted
5 Finalise and report on the assessment
- 5.1 Tools and equipment are removed, cleaned and stored appropriately
- 5.2 Assessment area is cleaned and rubbish disposed of, as appropriate
- 5.3 Conservation requirements resulting from the assessment are determined and confirmed with appropriate personnel
- 5.4 Condition report is prepared and provided, as required
No information
No information
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| OAJ97 | MSFDG5001 | Assess conservation requirements | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J751 | MSF50113 | Diploma of Stained Glass and Leadlighting | Qualification |