Unit of competency Outline

Date retreived
22/07/2026 11:58 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Conduct compliance inspection of special LV electrical installations

Conduct compliance inspection of special LV electrical installations

Unit of competency
National Code
UEENEEG124A
State Code
WC482
TGA Status
Replaced
DTWD Status
Replaced
Current Release Number
2.00
Current Release Date
14/08/2013
State Implementation and Classification
Approved Date
24/07/2014
Field of Education
031313 - Electrical Fitting, Electrical Mechanics
Original Release Date
24/07/2014
Nominal Hours
54
Description
1)Scope:1.1) DescriptorThis unit covers inspection of electrical installation in marinas, moveable premises and caravan parks, medical treatment centres, construction and demolition sites in consumer’s premises for verifying compliance with electrical safety regulations. It encompasses working safely, conducting tests and inspections, documenting non-compliance defects, taking/recommending actions resulting from non-compliance defects, applying regulatory requirements and completing inspection reports.Note:Competency in verifying compliance of installations for hazardous areas is covered by “M” units:
Notes
Elements and Performance Criteria
1 Prepare to conduct compliance inspection.
  • 1.1 OHS procedures for a given work area are identified, obtained and understood.
  • 1.2 Established OHS risk control measures and procedures in preparation for the work are followed.
  • 1.3 Safety hazards that have not previously been identified are documented and risk control measures devised and implemented in consultation with appropriate person(s).
  • 1.4 Documentation or deemed to comply standard on which installation is based is reviewed and understood.
  • 1.5 Appropriate person(s) are consulted to ensure the work is coordinated effectively with others involved on the work site.
  • 1.6 Tools, equipment and testing devices needed to verify compliance are obtained in accordance with established procedures and checked for correct operation and safety.
2 Conduct compliance inspect.
  • 2.1 OHS risk control measures and procedures for carrying out the work are followed.
  • 2.2 The need to test or measure live is determined in strict accordance with OHS requirements and when necessary conducted within established safety procedures.
  • 2.3 Circuits/machines/plant are checked as being isolated where necessary in strict accordance OHS requirements and procedures.
  • 2.4 Detailed inspection of the consumer’s mains and main switchboard is conducted methodically to ascertain compliance of protection, metering, earthing, circuit arrangements and markings.
  • 2.5 Detailed inspection of circuits is conducted methodically to ascertain the compliance of the installed wiring, accessories, switchgear / control gear and current-using devices.
  • 2.6 Where deemed necessary, evidence that electrical equipment complies with safety requirements is sought from appropriate person(s) and sighted.
  • 2.7 Detailed inspection is conducted to verify compliance of earthing, insulation, polarity, circuit connections and operation of Residual current devices.
  • 2.8 Fault-loop impedance is ascertained as being sufficiently low by testing, calculation or deemed to comply with arrangement of the installation.
  • 2.9 Methods for dealing with unexpected situations are selected on the basis of safety and specified work outcomes.
3 Act and report on inspection findings.
  • 3.1 OHS work completion risk control measures and procedures are followed.
  • 3.2 Non-compliance defects are identified with appropriate clauses in regulatory standards and documented in accordance with established procedures.
  • 3.3 Actions are taken as a result of non-compliance within the scope of inspection responsibilities and authority and documented.
  • 3.4 Inspection report is made and issued to appropriate person(s) in accordance with established procedures.
RANGE STATEMENT
10) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance.
This unit shall be demonstrated by conducting compliance inspection of at least three of the following types of installations.
Caravan parks,
Construction and demolition sites,
Marinas,
Medical treatment areas,
Moveable premises
The electrical installations shall comprise consumers’ mains, main earthing system and main switchboard and sub-mains, earthing system and distribution boards, final sub circuits and requirement particular to the installation type.
Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1.
EVIDENCE GUIDE
9) The evidence guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for this Training Package.
The Evidence Guide forms an integral part of this unit. It must be used in conjunction with all parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.

Overview of Assessment
9.1)

Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the Industry’s preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accordance with industry and regulatory policy.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be ‘rich’ in nature to minimise error in judgment.
Activities associated with normal every day work have a bearing on the decision as to how much and how detailed the data gathered will contribute to its ‘richness’. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.

Critical aspects of evidence required to demonstrate competency in this unit
9.2)

Before the critical aspects of evidence are considered all prerequisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated performance criteria shall be demonstrated on at least two occasions in accordance with the ‘Assessment Guidelines - UEE11’. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:
Implement Occupational Health and Safety workplace procedures and practices including the use of risk control measures as specified in the performance criteria and range statement
Apply sustainable energy principles and practices as specified in the performance criteria and range statement
Demonstrate an understanding of the essential knowledge and associated skills as described in this unit. It may be required by some jurisdictions that RTOs provide a percentile graded result for the purpose of regulatory or licensing requirements.
Demonstrate an appropriate level of skills enabling employment
Conduct work observing the relevant Anti Discrimination legislation, regulations, polices and workplace procedures
Demonstrated consistent performance across a representative range of contexts from the prescribed items below:
Conduct compliance inspection of special electrical installations as described in 8) and including:
A Obtaining appropriate documentation and equipment in preparation for the inspection.
B Conducting Detailed inspections and testing methodically.
C Identifying non-compliance defects.
D Relating non-compliance defects with appropriate clause in regulatory standards.
E Acting within the inspection authority when dealing with non-compliance defects.
F Documenting and reporting inspection findings.
G Dealing with unplanned events by drawing on essential knowledge and skills to provide appropriate solutions incorporated in the holistic assessment with the above listed items.

Context of and specific resources for assessment
9.3)

This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this unit.
These should be part of the formal learning/assessment environment.
Note:
Where simulation is considered a suitable strategy for assessment, conditions must be authentic and as far as possible reproduce and replicate the workplace and be consistent with the approved industry simulation policy.
The resources used for assessment should reflect current industry practices in relation to conducting compliance inspection of special electrical installations.

Method of assessment
9.4)

This unit shall be assessed by methods given in Volume 1, Part 3 ‘Assessment Guidelines’.
Note:
Competent performance with inherent safe working practices is expected in the industry to which this unit applies. This requires assessment in a structured environment which is primarily intended for learning/assessment and incorporates all necessary equipment and facilities for learners to develop and demonstrate the essential knowledge and skills described in this unit.

Concurrent assessment and relationship with other units
9.5)

There are no concurrent assessment recommendations for this unit.
The critical aspects of occupational health and safety covered in unit UEENEEE101A and other discipline specific occupational health and safety units shall be incorporated in relation to this unit.
Replaced By
State Code National Code Title Type
OBZ47 UEEEL0031 Conduct compliance inspection of special LV electrical installations Unit of competency