Qualification Outline

Date retreived
22/07/2026 5:18 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate IV in Energy Management and Control

Certificate IV in Energy Management and Control

Qualification
National Code:
UEE41011
State Code:
A141
TGA Status:
Replaced
DTWD Status:
Replaced
National Endorsed, State Implementation and Classification
Field of Education
0313 - Electrical And Electronic Engineering And Technology
Original TGA Release Date
17/04/2014
Approved Date
24/07/2014
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
C
Nominal Hours
1152
Duration
3 Semesters
Current Release Number
4.00
Current Release Date
17/04/2014
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
4.00 17/04/2014 Current Transition (Replaced)
Description

Scope
This qualification provides competencies to develop strategies for the reduction of energy in buildings and to recommend changes in the way in which energy is controlled in the building either by the installation of new control equipment or by the modification or re-programming of that existing. It includes ERAC requirements for an ‘Electrician’s licence’.
^ From 1 July 2022 the elective unit HLTAID001 must no longer be delivered and will be replaced in the Packaging Rules by the unit HLTAID009 - for more information see: https://asqa.gov.au/news-events/news/reminder-about-superseded-hlt-first-aid-units

Schedule
Packaging Rules
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- Twenty three (23) core units and
- A combination of elective units to achieve a total weighting of 300 points:
- A maximum of 100 weighting points may be chosen from Group A Imported and Common Elective Units
- A maximum of 100 weighting points may be chosen from Group B Elective Units
- A minimum of 200 to a maximum of 300 weighting points to be chosen from Group C Elective Units

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.


Note: UEENEEG105A - those holding an 'Unrestricted Electricians Licence' or equivalent issued in an Australian State or Territory meets the requirements of this unit and its pre-requisite requirements
1. Core Units

All twenty three (23) units must be completed

State Code National Code Title Hours Type
S7307 UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace 18 Unit of competency
S7317 UEENEEG063A Arrange circuits, control and protection for general electrical installations 36 Unit of competency
WC429 UEENEEE124A Compile and produce an energy sector detailed report 54 Unit of competency
S7326 UEENEEG109A Develop and connect electrical control circuits 72 Unit of competency
WC719 UEENEEK152A Develop strategies to address sustainability issues for electrical installations 18 Unit of competency
S7314 UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work 18 Unit of competency
S7308 UEENEEE102A Fabricate, assemble and dismantle utilities industry components 36 Unit of competency
S7310 UEENEEE105A Fix and secure electrotechnology equipment 18 Unit of competency
WC714 UEENEEK145A Implement and monitor energy sector environmental and sustainable policies and procedures 18 Unit of competency
WC423 UEENEEE117A Implement and monitor energy sector OHS policies and procedures 18 Unit of competency
S8321 UEENEEG104A Install appliances, switchgear and associated accessories for low voltage electrical installations 18 Unit of competency
S7320 UEENEEG103A Install low voltage wiring and accessories 18 Unit of competency
W7839 UEENEEE038B Participate in development and follow a personal competency development plan 18 Unit of competency
S7324 UEENEEG107A Select wiring systems and cables for low voltage general electrical installations 54 Unit of competency
S7309 UEENEEE104A Solve problems in d.c. circuits 72 Unit of competency
S7318 UEENEEG101A Solve problems in electromagnetic devices and related circuits 54 Unit of competency
S7319 UEENEEG102A Solve problems in low voltage a.c. circuits 72 Unit of competency
S7316 UEENEEG033A Solve problems in single and three phase low voltage electrical apparatus and circuits 54 Unit of competency
S7315 UEENEEG006A Solve problems in single and three phase low voltage machines 72 Unit of competency
S7323 UEENEEG106A Terminate cables, cords and accessories for low voltage circuits 36 Unit of competency
S7325 UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits 36 Unit of competency
S7311 UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications 36 Unit of competency
S7322 UEENEEG105A Verify compliance and functionality of low voltage general electrical installations 36 Unit of competency
2. Group A Imported and Common Elective Units

Units may be chosen to a maximum of 100 weighting points from Group A.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
W7811 UEENEEE009B Comply with scheduled and preventative maintenance program processes 18 Unit of competency
W7740 UEENEEC010B Deliver a service to customers 18 Unit of competency
W7731 UEENEEC001B Maintain documentation 18 Unit of competency
W7822 UEENEEE020B Provide basic instruction in the use of electrotechnology apparatus 18 Unit of competency
WG730 HLTAID001 Provide cardiopulmonary resuscitation 3 Unit of competency
W7733 UEENEEC003B Provide quotations for installation or service jobs 18 Unit of competency
W7732 UEENEEC002B Source and purchase material/parts for installation or service jobs 18 Unit of competency
WC385 UEENEED101A Use computer applications relevant to a workplace 18 Unit of competency
W9434 CPCCOHS1001A Work safely in the construction industry 4 Unit of competency
3. Group B Elective Units

Units may be chosen to a maximum of 100 weighting points from Group B.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
WC632 UEENEEI116A Assemble, enter and verify operating instructions in microprocessor equipped devices 18 Unit of competency
WC657 UEENEEI141A Develop electrical integrated systems 18 Unit of competency
WC666 UEENEEI150A Develop, enter and verify discrete control programs for programmable controllers 54 Unit of competency
WC458 UEENEEF102A Install and maintain cabling for multiple access to telecommunication services 108 Unit of competency
WC527 UEENEEG189A Install and maintain emergency lighting systems 36 Unit of competency
WC474 UEENEEG113A Install and maintain emergency safety systems 54 Unit of competency
WC460 UEENEEF104A Install and modify performance data communication copper cabling 36 Unit of competency
S7328 UEENEEG171A Install, set up and commission interval metering 18 Unit of competency
WC426 UEENEEE121A Plan an integrated cabling installation system 36 Unit of competency
WC519 UEENEEG181A Provide advice on effective and energy efficient lighting products 18 Unit of competency
WC521 UEENEEG183A Provide advice on the application of energy efficient lighting for ambient and aesthetic effect 18 Unit of competency
WC532 UEENEEH102A Repairs basic electronic apparatus faults by replacement of components 36 Unit of competency
WC620 UEENEEI103A Solve problems in density/level measurement components and systems 36 Unit of competency
WC621 UEENEEI104A Solve problems in flow measurement components and systems 36 Unit of competency
WC619 UEENEEI102A Solve problems in pressure measurement components and systems 36 Unit of competency
WC622 UEENEEI105A Solve problems in temperature measurement components and systems 36 Unit of competency
WC520 UEENEEG182A Supply effective and efficient lighting products for domestic and small commercial applications 36 Unit of competency
WC541 UEENEEH111A Troubleshoot single phase input d.c. power supplies 36 Unit of competency
WC388 UEENEED104A Use engineering applications software on personal computers 36 Unit of competency
4. Group C Elective Units

A minimum of 200 to a maximum of 300 weighting points to be chosen from Group C.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
WC721 UEENEEK154A Assess energy loads and uses for energy efficiency in commercial facilities 36 Unit of competency
WC722 UEENEEK155A Assess energy loads and uses for energy efficiency in industrial properties and enterprises 36 Unit of competency
WC720 UEENEEK153A Assess energy loads and uses for energy efficiency in residential, office and retail premises 36 Unit of competency
WC481 UEENEEG123A Conduct compliance inspection of LV electrical installations with demand exceeding 100 A per phase 36 Unit of competency
WC480 UEENEEG122A Conduct compliance inspection of single phase LV electrical installations 54 Unit of competency
WC482 UEENEEG124A Conduct compliance inspection of special LV electrical installations 54 Unit of competency
WC524 UEENEEG186A Design effective and efficient lighting for residential and commercial buildings 18 Unit of competency
WC515 UEENEEG175A Develop compliance policies and plans to conduct a electrical contracting business 72 Unit of competency
WC517 UEENEEG179A Develop detailed electrical drawings 54 Unit of competency
WC511 UEENEEG168A Diagnose and rectify faults in complex lift systems 36 Unit of competency
S7433 UEENEEG076A Install and replace low voltage current transformer metering 18 Unit of competency
WC514 UEENEEG172A Investigate and report on electrical incidents and causes 54 Unit of competency
WC483 UEENEEG125A Plan electrical installations with a low voltage demand up to 400 A per phase 36 Unit of competency
WC486 UEENEEG128A Plan low voltage switchboard and control panel layouts 36 Unit of competency
WC526 UEENEEG188A Prepare quotations for the supply of effective and efficient lighting products for lighting projects 18 Unit of competency
WC522 UEENEEG184A Provide photometric data for illumination system design 54 Unit of competency
WC523 UEENEEG185A Select effective and efficient light sources and luminaries for given locations and designs 54 Unit of competency
WC516 UEENEEG177A Select low voltage power factor correction equipment 36 Unit of competency
WC506 UEENEEG162A Set up and place LV electrical apparatus and associated circuits into service 36 Unit of competency
WC479 UEENEEG121A Verify compliance and functionality of special LV electrical installations 36 Unit of competency
W7860 UEENEEE073B Write specifications for refrigeration and air conditioning engineering projects 36 Unit of competency
Replaces
State Code National Code Title Type
W845 UEE41010 Certificate IV in Energy Management and Control Qualification
Replaced By
State Code National Code Title Type
BFL6 UEE41020 Certificate IV in Energy Management and Control Qualification
No information
Entry Requirements

Not applicable.

Traineeships and Apprenticeships
No information