Unit of competency Outline
Date retreived
22/07/2026 1:13 PM AWST
22/07/2026 1:13 PM AWST
Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.
Lead emergency teams
Lead emergency teams
Unit of competency
National Code
PMAOHS311B
PMAOHS311B
State Code
W8831
W8831
TGA Status
Replaced
Replaced
DTWD Status
Replaced
Replaced
State Implementation and Classification
Approved Date
05/09/2013
Field of Education
080399 - Business And Management, N.e.c.
Original Release Date
05/09/2013
Nominal Hours
20
Description
This unit of competency applies to an individual required to lead and coordinate an emergency team, including deployment of resources at the scene of an emergency.
Notes
Elements and Performance Criteria
1. Assess the nature and extent of the emergency
- 1.1. Determine the nature and extent of the emergency in order to ascertain the level and degree of the emergency and what required actions and management strategies should be implemented
- 1.2. Communicate the nature and extent of the emergency in a timely and appropriate manner to other nominated emergency or facility personnel
- 1.3. Facilitate the rescue of personnel at risk, control/extinguish the emergency and to make the affected area safe through application of rescue and control strategies
- 1.4. Ensure all team members are adequately instructed, protected and equipped to function safely and effectively in the emergency situation through the application of personal protective equipment.
2. Effect rescue of personnel at risk.
- 2.1. Instruct rescue teams to effect the search for, and rescue of, personnel identified as being at risk
- 2.2. Allocate resources to potentially exposed or threatened personnel and assets, and minimise the likelihood of escalation of the risk.
3. Confine the spread of emergency
- 3.1. Initiate control/extinguishing responses promptly in order to eliminate the emergency
- 3.2. Render affected areas safe in order to prevent the likelihood of further re-occurrence, or threat to personnel or assets
- 3.3. Provide feedback to facility or other nominated personnel concerning the status of the emergency.
RANGE STATEMENT
The Range Statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the Performance Criteria, is detailed below. Add any essential operating conditions that may be present with training and assessment depending on the work situation, needs if the candidate, accessibility of the item, and local industry and regional contexts.
Codes of practice/ standards
Where reference is made to industry codes of practice, and/or Australian/international standards, the latest version must be used.
Context
Those persons who normally operate or are based permanently or regularly assigned to an onshore or offshore installation or facility and lead an emergency response team would require this unit of competency.
This unit could be applied to any of the following installations or facilities:
onshore/offshore rig/installation
island based facility
floating production vessel or platform
onshore production, processing and/or storage facilities
pipeline easements
maintenance bases.
This competency covers process manufacturing plants which may involve workplace hazards such as:
chemicals and hazardous materials
gases and liquids under pressure
moving machinery
materials handling
working at heights, in restricted or confined spaces, or environments subjected to heat, noise, dusts or vapours.
Emergency situations may include:
accidents
fires
chemical or oil spills
gas leak or vapour emission
utilities failure
bomb scares.
Equipment may include:
fire extinguishing agents and water curtains
hoses
mobile extinguishers
stretchers
personal protective clothing and equipment such as:
chemical protective clothing
distress alarms
structural fire protective clothing
self contained breathing apparatus (SCBA)
communication equipment.
Emergency extinguishing media may include:
water
foam
extinguishing powder
gaseous extinguishing agents
vapourising liquids
other fire extinguishing substances.
On-scene hazards may include:
smoke, darkness and heat
electricity
gas
structural hazards
structural collapse
industrial - machinery, equipment, product
hazardous products and materials
unauthorised personnel.
Emergency strategies and tactics may include:
direct attack
indirect attack
combination attack
exposure protection
internal/offensive attacks
confining the spread of incident
rescuing occupants
cooling the fuels
removal of fuels
interrupting the chemical chain reaction
exclusion of oxygen.
Relevant facility fire management and safety systems include:
fire management systems
communication systems
relevant facility emergency management and contingency response plans.
Relevant legislative and safety case management principles and agreements must be adhered to.
Health, safety and environment (HSE)
All operations to which this unit applies are subject to stringent health, safety and environment requirements, which may be imposed through State or Federal legislation, and these must not be compromised at any time. Where there is an apparent conflict between Performance Criteria and HSE requirements, the HSE requirements take precedence.
The Range Statement relates to the unit of competency as a whole. It allows for different work environments and situations that may affect performance. Bold italicised wording, if used in the Performance Criteria, is detailed below. Add any essential operating conditions that may be present with training and assessment depending on the work situation, needs if the candidate, accessibility of the item, and local industry and regional contexts.
Codes of practice/ standards
Where reference is made to industry codes of practice, and/or Australian/international standards, the latest version must be used.
Context
Those persons who normally operate or are based permanently or regularly assigned to an onshore or offshore installation or facility and lead an emergency response team would require this unit of competency.
This unit could be applied to any of the following installations or facilities:
onshore/offshore rig/installation
island based facility
floating production vessel or platform
onshore production, processing and/or storage facilities
pipeline easements
maintenance bases.
This competency covers process manufacturing plants which may involve workplace hazards such as:
chemicals and hazardous materials
gases and liquids under pressure
moving machinery
materials handling
working at heights, in restricted or confined spaces, or environments subjected to heat, noise, dusts or vapours.
Emergency situations may include:
accidents
fires
chemical or oil spills
gas leak or vapour emission
utilities failure
bomb scares.
Equipment may include:
fire extinguishing agents and water curtains
hoses
mobile extinguishers
stretchers
personal protective clothing and equipment such as:
chemical protective clothing
distress alarms
structural fire protective clothing
self contained breathing apparatus (SCBA)
communication equipment.
Emergency extinguishing media may include:
water
foam
extinguishing powder
gaseous extinguishing agents
vapourising liquids
other fire extinguishing substances.
On-scene hazards may include:
smoke, darkness and heat
electricity
gas
structural hazards
structural collapse
industrial - machinery, equipment, product
hazardous products and materials
unauthorised personnel.
Emergency strategies and tactics may include:
direct attack
indirect attack
combination attack
exposure protection
internal/offensive attacks
confining the spread of incident
rescuing occupants
cooling the fuels
removal of fuels
interrupting the chemical chain reaction
exclusion of oxygen.
Relevant facility fire management and safety systems include:
fire management systems
communication systems
relevant facility emergency management and contingency response plans.
Relevant legislative and safety case management principles and agreements must be adhered to.
Health, safety and environment (HSE)
All operations to which this unit applies are subject to stringent health, safety and environment requirements, which may be imposed through State or Federal legislation, and these must not be compromised at any time. Where there is an apparent conflict between Performance Criteria and HSE requirements, the HSE requirements take precedence.
EVIDENCE GUIDE
The Evidence Guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Assessment of this unit should include demonstrated competence on actual plant and equipment in a work environment. The unit will be assessed in as holistic a manner as is practical and may be integrated with the assessment of other relevant units of competency. Assessment will occur over a range of situations which will include disruptions to normal, smooth operation.
Simulation may be required to allow for assessment of parts of this unit. Simulation should be based on the actual plant and will include walk-throughs of the relevant competency components. Simulations may also include the use of case studies/scenarios and role plays.
This unit of competency requires a significant body of knowledge which will be assessed through questioning and the use of what-if scenarios both on the plant (during demonstration of normal operations and walk-throughs of abnormal operations) and off the plant.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Competence must be demonstrated in the ability to recognise and analyse potential situations requiring action and then in implementing appropriate corrective action. The emphasis should be on the ability to minimise the effects of the critical situation.
Consistent performance should be demonstrated. In particular look for:
ability to work effectively as a team and as a team leader
recognition of the behaviour of fire and other emergency situations
impact of emergency tactics
evidence that emergency operations are conducted in accordance with the organisation's safe work practices.
These aspects may be best assessed using a range of scenarios/case studies/what ifs as the stimulus with a walk through forming part of the response. These assessment activities should include a range of problems, including new, unusual and extreme situations which may have been generated from the past incident history of the plant, incidents on similar plants around the world, hazard analysis activities (e.g. HAZOP) and similar sources.
Context of and specific resources for assessment
Assessment will require access to an operating plant over an extended period of time, or a suitable method of gathering evidence of operating ability over a range of situations. A bank of scenarios/case studies/what-ifs will be required as will a bank of questions which will be used to probe the reasoning behind the observable actions.
Method of assessment
The skills and knowledge contained within this unit of competency could be utilised as a normal part of a person's responsibilities and duties.
In all plants it may be appropriate to assess this unit concurrently with relevant teamwork and communication units.
It would be expected that a person undertaking this competency would have completed or be able to demonstrate competence in the following unit of competency before undertaking this unit:
MSAPMOHS212A Undertake first response to fire incidents
PMAOHS213B Undertake fire control and emergency rescue.
Guidance information for assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the oracy, language and literacy capacity of the assessee and the work being performed.
The Evidence Guide provides advice on assessment and must be read in conjunction with the Performance Criteria, Required Skills and Knowledge, the Range Statement and the Assessment Guidelines for the Training Package.
Overview of assessment
Assessment of this unit should include demonstrated competence on actual plant and equipment in a work environment. The unit will be assessed in as holistic a manner as is practical and may be integrated with the assessment of other relevant units of competency. Assessment will occur over a range of situations which will include disruptions to normal, smooth operation.
Simulation may be required to allow for assessment of parts of this unit. Simulation should be based on the actual plant and will include walk-throughs of the relevant competency components. Simulations may also include the use of case studies/scenarios and role plays.
This unit of competency requires a significant body of knowledge which will be assessed through questioning and the use of what-if scenarios both on the plant (during demonstration of normal operations and walk-throughs of abnormal operations) and off the plant.
Critical aspects for assessment and evidence required to demonstrate competency in this unit
Competence must be demonstrated in the ability to recognise and analyse potential situations requiring action and then in implementing appropriate corrective action. The emphasis should be on the ability to minimise the effects of the critical situation.
Consistent performance should be demonstrated. In particular look for:
ability to work effectively as a team and as a team leader
recognition of the behaviour of fire and other emergency situations
impact of emergency tactics
evidence that emergency operations are conducted in accordance with the organisation's safe work practices.
These aspects may be best assessed using a range of scenarios/case studies/what ifs as the stimulus with a walk through forming part of the response. These assessment activities should include a range of problems, including new, unusual and extreme situations which may have been generated from the past incident history of the plant, incidents on similar plants around the world, hazard analysis activities (e.g. HAZOP) and similar sources.
Context of and specific resources for assessment
Assessment will require access to an operating plant over an extended period of time, or a suitable method of gathering evidence of operating ability over a range of situations. A bank of scenarios/case studies/what-ifs will be required as will a bank of questions which will be used to probe the reasoning behind the observable actions.
Method of assessment
The skills and knowledge contained within this unit of competency could be utilised as a normal part of a person's responsibilities and duties.
In all plants it may be appropriate to assess this unit concurrently with relevant teamwork and communication units.
It would be expected that a person undertaking this competency would have completed or be able to demonstrate competence in the following unit of competency before undertaking this unit:
MSAPMOHS212A Undertake first response to fire incidents
PMAOHS213B Undertake fire control and emergency rescue.
Guidance information for assessment
Assessment processes and techniques must be culturally appropriate and appropriate to the oracy, language and literacy capacity of the assessee and the work being performed.
Replaces
| State Code | National Code | Title | Type |
|---|---|---|---|
| C6022 | PMAOHS311A | Lead emergency teams | Unit of competency |
Replaced By
| State Code | National Code | Title | Type |
|---|---|---|---|
| AXM14 | PMAWHS311 | Lead emergency teams | Unit of competency |
| State Code | National Code | Title | Type |
|---|---|---|---|
| J835 | UEG40114 | Certificate IV in Gas Supply Industry Operations | Qualification |
| J834 | UEG30114 | Certificate III in Gas Supply Industry Operations | Qualification |
| J572 | PMA30113 | Certificate III in Process Plant Operations | Qualification |
| W516 | PMA30108 | Certificate III in Process Plant Operations | Qualification |
| J571 | PMA40113 | Certificate IV in Process Plant Technology | Qualification |
| W517 | PMA40108 | Certificate IV in Process Plant Technology | Qualification |