Qualification Outline

Date retreived
22/07/2026 6:25 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate III in ESI - Very Remote Community Utilities

Certificate III in ESI - Very Remote Community Utilities

Qualification
National Code:
UET30921
State Code:
BHB4
TGA Status:
Current
DTWD Status:
Approved
National Endorsed, State Implementation and Classification
Field of Education
0313 - Electrical And Electronic Engineering And Technology
Original TGA Release Date
20/09/2021
Approved Date
21/12/2021
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
A
Nominal Hours
990
Duration
3 Semesters
Current Release Number
1.00
Current Release Date
20/09/2021
VET Act Conditions
This apprenticeship applies to the construction, inspection, repair and maintenance of essential public utilities (generation and network assets) in a 'very remote community'. Work must be carried out in a non-energised (dead) environment other than for testing purposes. Prior to the commencement of work, all electrical apparatus is to be isolated. That is for High Voltage (short-circuited and earthed) and for Low Voltage (short-circuited to the neutral). 'Very remote community' is defined in terms of limited and/or long distance access along the road network and very limited accessibility to obtain goods, services and opportunities for social interaction within the Australian Statistical Geography Standard (ASGS) Statistical Area Level 3 (SA3) locations: - 50804 Kimberley (excluding the towns of Broome, Derby, Fitzroy Crossing, Halls Creek, Kununurra, Wyndham and mine sites); - 50806 Pilbara (excluding the towns/cities of Onslow, Dampier, Karratha, Newman, Paraburdoo, Port Hedland, Roebourne, South Hedland, Tom Price, Wickham and mine sites); - 50802 Gascoyne (excluding the towns of Carnarvon, Exmouth and mine sites); - 50805 Mid West (excluding the towns of Dongara, Geraldton, Greenough, Jurien, Kalbarri, Meekatharra, Mt Magnet, Morawa, Northampton, Port Denison, and mine sites); - 50803 Goldfields (excluding the towns/cities of Boulder, Kalgoorlie, Kambalda, Leinster, Leonora, Norseman and mine sites); - 50801 Esperance (excluding the town of Esperance and mine sites); - 90101 Christmas Island (no exclusions); and - 90102 Cocos Island (no exclusions). It excludes SA4 locations: 501 Bunbury; 502 Mandurah; 503 Perth-Inner; 504 Perth-North East; 505 Perth North West; 506 Perth-South East; 507 Perth-South West; and 509 Western Australia - Wheatbelt.
Releases
Release Version Release Date TGA Status DTWD Status
1.00 20/09/2021 Current Approved
Description

This qualification provides the skill and knowledge to work on very remote community utility systems as a remote community utilities worker in the electricity supply industry (ESI).
The qualification covers the skills and knowledge to operate, monitor and maintain generation power systems, distribution electrical network circuits and apparatus, and specialisations in power and water systems.
Combined Specialist - Power and Water Systems
This combined specialisation covers the skills and knowledge required to work on very remote community utility power and water systems.
Specialist - Power Systems
This specialisation covers the skills and knowledge required to install, operate, monitor and maintain distribution overhead and underground networks and customer connections. It also includes the skills and knowledge required to monitor and maintain renewable energy systems.
Specialist - Water Systems
This specialisation covers the skills and knowledge required to install, operate, monitor and maintain water systems.
All work on power systems will be undertaken on isolated assets other than for testing purposes.
The use of support plant and equipment to perform these tasks and environmental requirements also play a part in this qualification.
Please note: RTO to insert on the testamur, the specialisation selected from the specialist elective unit group below.
Very Remote Communities: means a community with restricted access and very little accessibility of goods, services and opportunities for social interaction. Supporting information on the classification of a very remote community can be defined using the latest version of Accessibility/Remoteness Index of Australia (ARIA) (excluding mine sites).
Isolated: Means disconnected from all possible sources of electricity supply by means that prevent unintentional energisation of the apparatus and that are assessed as a suitable step in the process of making safe for access purposes. That is for high voltage (HV) (short-circuited and earthed) and for low voltage (LV) (short-circuited to the neutral).
The application of the skills and knowledge described within the units in this qualification may require a licence/registration to practice in the workplace.
Other conditions may also apply under state and territory legislative and regulatory licensing requirements which must be confirmed prior to commencing this qualification.

Schedule
Packaging Rules
A total of twenty four (24) units comprising:

Combined Specialisation - Power and Water Systems
- Seventeen (17) core units listed below, plus
- Seven (7) elective units from a combination of Group A and Group B below.

Specialisation - Power Systems
- Seventeen (17) core units listed below, plus
- Seven (7) elective units from Group A listed below.

Specialisation- Water Systems
- Seventeen (17) core units listed below, plus
- Seven (7) elective units from Group B listed below.

Up to one (1) elective unit may be selected, with appropriate contextualisation, from a qualification in this or any endorsed Training Package, provided the selected unit contributes to the vocational outcome of the qualification.

Where imported units are selected, care must be taken to ensure all prerequisite units specified are complied with. Prerequisites attached to any of the units must be obtained and are additional to the number of units required for the qualification.

Where a prerequisite is attached to a unit it is identified by the symbol ∟.
1. Core Units

All seventeen (17) units must be completed.

State Code National Code Title Hours Type
ODN07 UETDREL001 Apply environmental requirements 18 Unit of competency
OCA55 UEECD0007 Apply work health and safety regulations, codes and practices in the workplace 18 Unit of competency
OCC54 UEERE0007 Conduct periodic maintenance of remote area power supply generator sets 36 Unit of competency
OBX42 UEECD0019 Fabricate, assemble and dismantle utilities industry components 36 Unit of competency
OCA05 UEERE0018 Maintain and repair remote area power generation facilities 108 Unit of competency
OBX68 UEERE0041 Maintain operation of remote area power generation plant 108 Unit of competency
OBY78 UEERE0019 Maintain safety and tidiness of remote area power supply systems 18 Unit of competency
ODN35 UETDRRC005 Maintain, test and verify power systems in a very remote community 70 Unit of competency
ODN10 UETDREL004 Operate plant and equipment in the vicinity of live electrical apparatus 36 Unit of competency
ODM59 UETDRRC006 Perform low voltage electricity network switching in a very remote community 36 Unit of competency
ODN36 UETDRRC007 Solve problems in electrical network apparatus in a very remote community 72 Unit of competency
ODN37 UETDRRC008 Solve problems in low voltage electrical network circuits in a very remote community 72 Unit of competency
OBY68 UEECD0044 Solve problems in multiple path circuits 36 Unit of competency
OCA07 UEECD0046 Solve problems in single path circuits 36 Unit of competency
OCC28 UEECD0051 Use drawings, diagrams, schedules, standards, codes and specifications 36 Unit of competency
ODN11 UETDREL005 Work safely in the vicinity of live electrical apparatus 18 Unit of competency
OBZ03 UEERE0023 Work safely with remote area power supply systems 18 Unit of competency
2. Group A: Power Systems

For specialisation in Power Systems, seven (7) elective units must be selected from Group B.
Please refer to the packaging rules for the full details of each specialisation.

State Code National Code Title Hours Type
OCA42 UEERE0006 Conduct periodic maintenance of remote area power supply battery banks 36 Unit of competency
OCC23 UEERE0008 Conduct periodic maintenance of remote area power supply photovoltaic arrays 36 Unit of competency
OBX45 UEERE0009 Conduct periodic maintenance of remote area power supply wind generators 36 Unit of competency
ODM68 UETDRDO001 Inspect overhead poles, structures and electrical apparatus 40 Unit of competency
ODN19 UETDRIS007 Install and maintain distribution overhead conductors and cables 54 Unit of competency
ODN31 UETDRRC001 Install and maintain low voltage overhead services in a very remote community 36 Unit of competency
ODN32 UETDRRC002 Install and maintain low voltage underground services in a very remote community 36 Unit of competency
ODN24 UETDRIS012 Install and maintain poles, structures and hardware 45 Unit of competency
ODN33 UETDRRC003 Install and maintain public lighting systems in a very remote community 36 Unit of competency
ODN34 UETDRRC004 Install and replace energy meters and associated equipment in a very remote community 45 Unit of competency
ODN00 UETDRDU013 Joint, terminate and maintain high voltage underground polymeric cable 45 Unit of competency
ODN02 UETDRDU015 Joint, terminate and maintain low voltage underground polymeric cable 60 Unit of competency
ODN03 UETDRDU016 Lay power cables 18 Unit of competency
3. Group B: Water Systems

For specialisation in Water Systems, seven (7) elective units must be selected from Group B.
Please refer to the packaging rules for the full details of each specialisation.

State Code National Code Title Hours Type
OBO20 NWPGEN017 Apply the risk management principles of the water industry standards, guidelines and legislation 10 Unit of competency
OBN95 NWPNET020 Control electrical risk on metallic pipes 10 Unit of competency
OBN87 NWPNET038 Install metering equipment 35 Unit of competency
OBN91 NWPNET039 Maintain and repair network assets for drinking water 45 Unit of competency
OBN86 NWPNET040 Maintain and repair network assets for wastewater 45 Unit of competency
OBO38 NWPCAD004 Maintain catchment and surrounding areas 40 Unit of competency
OBO22 NWPCAD019 Monitor and operate groundwater extraction 35 Unit of competency
OBO12 NWPGEN027 Monitor and operate pump stations 30 Unit of competency
OBN59 NWPTRT027 Monitor and operate wastewater treatment processes 45 Unit of competency
OBN75 NWPTRT005 Monitor and operate water treatment processes 45 Unit of competency
OBN89 NWPNET036 Perform leak detection 20 Unit of competency
OBO21 NWPGEN020 Sample and test source or drinking water 35 Unit of competency
OBO17 NWPGEN021 Sample and test wastewater 35 Unit of competency
OBO14 NWPGEN023 Use maps, plans, drawings and details 25 Unit of competency
Replaces
State Code National Code Title Type
BEW5 UET30919 Certificate III in ESI - Remote Community Utilities Worker Qualification
No information
Entry Requirements

There are no entry requirements for this qualification

Traineeships and Apprenticeships
(AP02540) REMOTE COMMUNITIES UTILITIES WORKER Apprenticeship