Qualification Outline

Date retreived
22/07/2026 5:30 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Certificate IV in Hazardous areas - Electrical

Certificate IV in Hazardous areas - Electrical

Qualification
National Code:
UEE42611
State Code:
A151
TGA Status:
Replaced
DTWD Status:
Replaced
National Endorsed, State Implementation and Classification
Field of Education
0313 - Electrical And Electronic Engineering And Technology
Original TGA Release Date
17/04/2014
Approved Date
24/09/2012
Stream of Study
Initial Vocational (3100 - 3600)
VET Act Classifier
B
Nominal Hours
1152
Duration
2 Semesters
Current Release Number
4.00
Current Release Date
17/04/2014
VET Act Conditions
Releases
Release Version Release Date TGA Status DTWD Status
4.00 17/04/2014 Current Transition (Replaced)
Description

Scope
This qualification provides competencies to supervise selection, installation, commissioning maintenance and testing of explosion-protected equipment and systems for control and monitoring of plant and processes. The qualification provides competencies in working with explosion protections techniques with elections in how they apply to coal mining, gas and dust atmospheres. It includes ERAC requirements for an ‘Electrician’s licence’ and competencies to select, install, set up, test, fault find, repair and maintain stand alone renewable energy equipment and systems.
^ From 1 July 2022 the elective unit HLTAID001 must no longer be delivered and will be replaced in the Packaging Rules by the unit HLTAID009 - for more information see: https://asqa.gov.au/news-events/news/reminder-about-superseded-hlt-first-aid-units

Schedule
Packaging Rules
The requirements for granting this qualification will be met when competency is demonstrated and achieved for:
- Twenty three (23) core units and
- A combination of elective units to achieve a total weighting of 300 points:
- A maximum of 60 weighting points may be chosen from Group A Imported and Common Elective Units
- A maximum of 80 weighting points may be chosen from Group B Elective Units
- A minimum of 220 to a maximum of 300 weighting points to be chosen from Group C Elective Units

Imported units from other training packages and/or state accredited courses can be added to this group, but they must be selected from qualifications where the unit is first packaged at AQF level 4. If units have not being assigned a weighting by the relevant EE-Oz Industry Technical Advisory Committee, their weighting will be 10 points.

Note:
1. Prerequisite pathways shall be identified and met for all elective units selected.
2. In selecting elective units considerations to career planning advice should be given to units that form part of a prerequisite pathway for the progression to achieve particular competencies or qualification at a higher level.

Note: UEENEEG105A - those holding an 'Unrestricted Electricians Licence' or equivalent issued in an Australian State or Territory meets the requirements of this unit and its pre-requisite requirements
1. Core Units

All twenty three (23) units must be completed

State Code National Code Title Hours Type
S7307 UEENEEE101A Apply Occupational Health and Safety regulations, codes and practices in the workplace 18 Unit of competency
S7317 UEENEEG063A Arrange circuits, control and protection for general electrical installations 36 Unit of competency
WC429 UEENEEE124A Compile and produce an energy sector detailed report 54 Unit of competency
S7326 UEENEEG109A Develop and connect electrical control circuits 72 Unit of competency
S7314 UEENEEE137A Document and apply measures to control OHS risks associated with electrotechnology work 18 Unit of competency
S7308 UEENEEE102A Fabricate, assemble and dismantle utilities industry components 36 Unit of competency
S7310 UEENEEE105A Fix and secure electrotechnology equipment 18 Unit of competency
WC714 UEENEEK145A Implement and monitor energy sector environmental and sustainable policies and procedures 18 Unit of competency
WC423 UEENEEE117A Implement and monitor energy sector OHS policies and procedures 18 Unit of competency
S8321 UEENEEG104A Install appliances, switchgear and associated accessories for low voltage electrical installations 18 Unit of competency
S7320 UEENEEG103A Install low voltage wiring and accessories 18 Unit of competency
W7839 UEENEEE038B Participate in development and follow a personal competency development plan 18 Unit of competency
D3645 UEENEEM080A Report on the integrity of explosion-protected equipment in a hazardous area 18 Unit of competency
S7324 UEENEEG107A Select wiring systems and cables for low voltage general electrical installations 54 Unit of competency
S7309 UEENEEE104A Solve problems in d.c. circuits 72 Unit of competency
S7318 UEENEEG101A Solve problems in electromagnetic devices and related circuits 54 Unit of competency
S7319 UEENEEG102A Solve problems in low voltage a.c. circuits 72 Unit of competency
S7316 UEENEEG033A Solve problems in single and three phase low voltage electrical apparatus and circuits 54 Unit of competency
S7315 UEENEEG006A Solve problems in single and three phase low voltage machines 72 Unit of competency
S7323 UEENEEG106A Terminate cables, cords and accessories for low voltage circuits 36 Unit of competency
S7325 UEENEEG108A Trouble-shoot and repair faults in low voltage electrical apparatus and circuits 36 Unit of competency
S7311 UEENEEE107A Use drawings, diagrams, schedules, standards, codes and specifications 36 Unit of competency
S7322 UEENEEG105A Verify compliance and functionality of low voltage general electrical installations 36 Unit of competency
2. Group A Imported and Common Elective Units

Units may be chosen to a maximum of 60 weighting points from Group A.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
W7811 UEENEEE009B Comply with scheduled and preventative maintenance program processes 18 Unit of competency
W7740 UEENEEC010B Deliver a service to customers 18 Unit of competency
W7731 UEENEEC001B Maintain documentation 18 Unit of competency
W7822 UEENEEE020B Provide basic instruction in the use of electrotechnology apparatus 18 Unit of competency
WG730 HLTAID001 Provide cardiopulmonary resuscitation 3 Unit of competency
W7733 UEENEEC003B Provide quotations for installation or service jobs 18 Unit of competency
W7732 UEENEEC002B Source and purchase material/parts for installation or service jobs 18 Unit of competency
WC385 UEENEED101A Use computer applications relevant to a workplace 18 Unit of competency
W9434 CPCCOHS1001A Work safely in the construction industry 4 Unit of competency
3. Group B Elective Units

Units may be chosen to a maximum of 80 weighting points from Group B.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
D3585 UEENEEM019A Attend to breakdowns in hazardous areas - coal mining 18 Unit of competency
D3587 UEENEEM021A Attend to breakdowns in hazardous areas - dust atmospheres 18 Unit of competency
D3586 UEENEEM020A Attend to breakdowns in hazardous areas - gas atmospheres 18 Unit of competency
D3588 UEENEEM022A Attend to breakdowns in hazardous areas - pressurisation 18 Unit of competency
D3625 UEENEEM060A Carry out overhaul and repair of explosion-protected equipment - coal mining 54 Unit of competency
D3628 UEENEEM063A Carry out overhaul and repair of explosion-protected equipment - dust atmospheres 54 Unit of competency
D3626 UEENEEM061A Carry out overhaul and repair of explosion-protected equipment - flameproof enclosures 54 Unit of competency
D3627 UEENEEM062A Carry out overhaul and repair of explosion-protected equipment - gas atmospheres 54 Unit of competency
D3637 UEENEEM072A Inspect and fit plugs/couplers for reeling, trailing and flexible cables 54 Unit of competency
D3642 UEENEEM077A Install and maintain the integrity of fixed gas detection equipment 18 Unit of competency
D3589 UEENEEM023A Install explosion-protected equipment and wiring systems - coal mining 54 Unit of competency
D3591 UEENEEM025A Install explosion-protected equipment and wiring systems - dust atmospheres 54 Unit of competency
D3590 UEENEEM024A Install explosion-protected equipment and wiring systems - gas atmospheres 54 Unit of competency
D3592 UEENEEM026A Install explosion-protected equipment and wiring systems - pressurisation 54 Unit of competency
D3593 UEENEEM027A Maintain equipment in hazardous areas - coal mining 54 Unit of competency
D3595 UEENEEM029A Maintain equipment in hazardous areas - dust atmospheres 54 Unit of competency
D3594 UEENEEM028A Maintain equipment in hazardous areas - gas atmospheres 54 Unit of competency
D3596 UEENEEM030A Maintain equipment in hazardous areas - pressurisation 54 Unit of competency
D3597 UEENEEM031A Overhaul and repair of explosion-protected equipment - coal mining 54 Unit of competency
D3600 UEENEEM034A Overhaul and repair of explosion-protected equipment - dust atmospheres 54 Unit of competency
D3598 UEENEEM032A Overhaul and repair of explosion-protected equipment - flameproof enclosures 54 Unit of competency
D3599 UEENEEM033A Overhaul and repair of explosion-protected equipment - gas atmospheres 54 Unit of competency
D3634 UEENEEM070A Repair reeling, trailing and flexible cables 54 Unit of competency
D3636 UEENEEM071A Test reeling, trailing and flexible cables 54 Unit of competency
D3641 UEENEEM076A Use and maintain the integrity of a portable gas detection device 18 Unit of competency
D3638 UEENEEM073A Verify compliance of repaired reeling, trailing and flexible cables 54 Unit of competency
4. Group C Elective Units

A minimum of 100 to a maximum of 160 weighting points to be chosen from Group C.
Please refer to the Training Package for the full list of unit weighting points.

State Code National Code Title Hours Type
D3609 UEENEEM043A Conduct detailed inspection of hazardous areas installations - coal mining 36 Unit of competency
D3611 UEENEEM045A Conduct detailed inspection of hazardous areas installations - dust atmospheres 36 Unit of competency
D3610 UEENEEM044A Conduct detailed inspection of hazardous areas installations - gas atmospheres 36 Unit of competency
D3612 UEENEEM046A Conduct detailed inspection of hazardous areas installations - pressurisation 36 Unit of competency
D3607 UEENEEM041A Conduct testing of hazardous area installations - pressurisation 36 Unit of competency
D3604 UEENEEM038A Conduct testing of hazardous areas installations - coal mining 36 Unit of competency
D3606 UEENEEM040A Conduct testing of hazardous areas installations - dust atmospheres 36 Unit of competency
D3605 UEENEEM039A Conduct testing of hazardous areas installations - gas atmospheres 36 Unit of competency
D3608 UEENEEM042A Conduct visual inspection of hazardous areas installations 36 Unit of competency
D3613 UEENEEM047A Develop and manage maintenance programs for hazardous areas electrical equipment - coal mining 18 Unit of competency
D3615 UEENEEM049A Develop and manage maintenance programs for hazardous areas electrical equipment - dust atmospheres 18 Unit of competency
D3614 UEENEEM048A Develop and manage maintenance programs for hazardous areas electrical equipment - gas atmospheres 18 Unit of competency
D3616 UEENEEM050A Develop and manage maintenance programs for hazardous areas electrical equipment - pressurisation 18 Unit of competency
D3643 UEENEEM078A Manage compliance of hazardous areas 18 Unit of competency
D3620 UEENEEM055A Plan electrical installations for hazardous areas - dust atmospheres 18 Unit of competency
D3621 UEENEEM056A Plan electrical installations for hazardous areas - pressurisation 18 Unit of competency
D3639 UEENEEM074A Plan electrical installations in hazardous areas - Coal mining 18 Unit of competency
Replaces
State Code National Code Title Type
W859 UEE42610 Certificate IV in Hazardous areas - Electrical Qualification
Replaced By
State Code National Code Title Type
BFL5 UEE42620 Certificate IV in Hazardous areas - Electrical Qualification
No information
Entry Requirements

Not applicable.

Traineeships and Apprenticeships
(TR09090) HAZARDOUS AREAS (LEVEL 4) Traineeship

Part-time is defined as a minimum of 20 hours per week.