Unit of competency Outline

Date retreived
23/07/2026 6:58 AM AWST

Whilst all efforts are made to provide accurate and timely information from the relevant source/documentation, please be aware that the information supplied may not be the most current version. The accuracy of the detail has not been confirmed by the Department and therefore should not be relied upon without first confirming the contents.

Report on the integrity of explosion-protected equipment in a hazardous area

Report on the integrity of explosion-protected equipment in a hazardous area

Unit of competency
National Code
UEENEEM080A
State Code
D3645
TGA Status
Deleted
DTWD Status
Deleted
Current Release Number
4.00
Current Release Date
16/12/2014
State Implementation and Classification
Approved Date
28/07/2014
Field of Education
031399 - Electrical And Electronic Engineering And Technology, N.e.c.
Original Release Date
28/07/2014
Nominal Hours
18
Description
1) 1.1) DescriptorThis unit covers the explosion-protection aspects of plant and machinery operation and maintenance. It requires the ability to visually identify any damage or deterioration of explosion-protected equipment, monitor changes in the explosion hazard and to implement procedures established to limit the risk of an explosion.This unit is directly equivalent to the Unit 2.2 Report on the integrity of explosion-protected equipment in hazardous areas in the Australian/New Zealand Standard AS/NZS 4761.1 Competencies for working with electrical equipment for hazardous areas (EEHA) Part 1: Competency Standards. Equivalence includes endorsement in the explosion-protection techniques listed in the Range statement of this unit.
Notes
Elements and Performance Criteria
1 Prepare to work in hazardous area.
  • 1.1 Nature of the explosion hazard in the area is known and the status of the explosion hazard is ascertained through established procedures.
  • 1.2 Operation and condition of plant and machinery, with regards to explosion-protection, is ascertained through established procedures.
  • 1.3 Established procedures for use of the plant and machinery, with regards to explosion-protection techniques used in the area, are followed.
2 Observe condition of explosion-protection system area.
  • 2.1 OHS policies and procedures, with regards to explosion-protection, are followed.
  • 2.2 Performance of plant and machinery is monitored to identify faults that may affect the integrity of the explosion-protected equipment and wiring system.
  • 2.3 Observations of explosion-protected equipment and wiring are made during normal operations and visual non-conformances that may affect the integrity of the explosion-protection technique are identified.
  • 2.4 Explosion hazard monitoring equipment is observed and a potentially dangerous state of the hazard is identified, e.g. by using gas detectors.
3 Take actions to limit risk of an explosion.
  • 3.1 Variations outside normal operating conditions are reported and documented in accordance with established procedures
  • 3.2 Non-conforming tools, equipment and testing devices are reported and documented in accordance with established procedures.
  • 3.3 Established procedures are followed in the event of a potential or immediate hazardous condition arising from any non-conformance identified in equipment/wiring or changes in the explosion hazard to a potentially dangerous state.
RANGE STATEMENT
8) This relates to the unit as a whole providing the range of contexts and conditions to which the performance criteria apply. It allows for different work environments and situations that will affect performance.
This unit shall be demonstrated in relation to any classified hazardous area.
Generic terms used throughout this Vocational Standard shall be regarded as part of the Range Statement in which competency is demonstrated. The definition of these and other terms that apply are given in Volume 2, Part 2.1.
EVIDENCE GUIDE
9) This provides essential advice for assessment of the unit and must be read in conjunction with the performance criteria and the range statement of the unit and the Training Package Assessment Guidelines.
The Evidence Guide forms an integral part of this unit. It must be used in conjunction with all components parts of this unit and performed in accordance with the Assessment Guidelines of this Training Package.
Overview of Assessment
9.1)
Longitudinal competency development approaches to assessment, such as Profiling, require data to be reliably gathered in a form that can be consistently interpreted over time. This approach is best utilised in Apprenticeship programs and reduces assessment intervention. It is the industry-preferred model for apprenticeships. However, where summative (or final) assessment is used it is to include the application of the competency in the normal work environment or, at a minimum, the application of the competency in a realistically simulated work environment. It is recognised that, in some circumstances, assessment in part or full can occur outside the workplace. However, it must be in accord with industry and regulatory policy.
Methods chosen for a particular assessment will be influenced by various factors. These include the extent of the assessment, the most effective locations for the assessment activities to take place, access to physical resources, additional safety measures that may be required and the critical nature of the competencies being assessed.
The critical safety nature of working with electricity, electrical equipment, gas or any other hazardous substance/material carries risk in deeming a person competent. Sources of evidence need to be 'rich' in nature to minimise error in judgment.
Activities associated with normal everyday work influence decisions about how/how much the data gathered will contribute to its 'richness'. Some skills are more critical to safety and operational requirements while the same skills may be more or less frequently practised. These points are raised for the assessors to consider when choosing an assessment method and developing assessment instruments. Sample assessment instruments are included for Assessors in the Assessment Guidelines of this Training Package.
Critical aspects of evidence required to demonstrate competency in this unit
9.2)
Before the critical aspects of evidence are considered all prerequisites shall be met.
Evidence for competence in this unit shall be considered holistically. Each element and associated performance criteria must be demonstrated on at least two occasions in accordance with the 'Assessment Guidelines - UEE07'. Evidence shall also comprise:
A representative body of work performance demonstrated within the timeframes typically expected of the discipline, work function and industrial environment. In particular this shall incorporate evidence that shows a candidate is able to:

Implement Occupational Health and Safety workplace procedures and practices, including the use of risk control measures as specified in the performance criteria and range statement
Apply sustainable energy principles and practices as specified in the performance criteria and range statement
Demonstrate an understanding of the essential knowledge and associated skills as described in this unit. It may be required by some jurisdictions that RTOs provide a percentile graded result for the purpose of regulatory or licensing requirements.
Demonstrate an appropriate level of skills enabling employment
Conduct work observing the relevant Anti Discrimination legislation, regulations, polices and workplace procedures

Demonstrated consistent performance across a representative range of contexts from the prescribed items below:

Report on the integrity of explosion-protected equipment in hazardous areas as described in 8) and including:


A
Following work permits and clearance procedures.


B
Monitoring hazards and following evacuation procedures.


C
Correctly operation of plant and machinery.


D
Following plant and electrical isolation procedures.


E
Identifying visual damage or deterioration of explosion-protected equipment.


F
Reporting visual defects.


G
Applying relevant contingency management skills.
Context of and specific resources for assessment
9.3)
This unit should be assessed as it relates to normal work practice using procedures, information and resources typical of a workplace. This should include:
OHS policy and work procedures and instructions.
Suitable work environment, facilities, equipment and materials to undertake actual work as prescribed by this unit.
These should also be part of the formal learning/assessment environment.
Note:
Where simulation is considered a suitable strategy for assessment, conditions must be authentic and as far as possible reproduce and replicate the workplace and be consistent with the approved industry simulation policy.

The resources used for assessment should reflect current industry practices in relation to reporting on the integrity of explosion protected equipment in hazardous areas.
Method of assessment
9.4)
This unit shall be assessed by methods given in Volume 1, Part 3 'Assessment Guidelines'.
Note:
Competent performance with inherent safe working practices is expected in the Industry to which this unit applies. This requires assessment in a structured environment primarily intended for learning/assessment which incorporates all necessary equipment and facilities for learners to develop and demonstrate the essential knowledge and skills described in this unit.
Concurrent assessment and relationship with other units
9.5)
For optimisation of training and assessment effort, competency development in this unit may be arranged in combination with other competencies required by a given industry or enterprise for plant or machinery operation or in relation to installation, maintenance or service functions.
Replaces
State Code National Code Title Type
W8184 UEENEEM001B Report on the integrity of explosion-protected equipment in hazardous areas Unit of competency
State Code National Code Title Type
A169 UEE61111 Advanced Diploma of Automated Systems Maintenance Engineering Qualification
A139 UEE40811 Certificate IV in Electrical - Fire Protection Control Systems Qualification
A135 UEE40411 Certificate IV in Electrical - Instrumentation Qualification
A158 UEE50411 Diploma of Electrical Engineering Qualification
A152 UEE43011 Certificate IV in Electrical Equipment and Systems Qualification
A131 UEE33011 Certificate III in Electrical Fitting Qualification
A176 UEE63011 Advanced Diploma of Electrical Systems Engineering Qualification
A164 UEE53011 Diploma of Electrical Systems Engineering Qualification
A138 UEE40611 Certificate IV in Electrotechnology - Systems Electrician Qualification
A123 UEE30811 Certificate III in Electrotechnology Electrician Qualification
A170 UEE61211 Advanced Diploma of Engineering - Explosion protection Qualification
W834 UEE31910 Certificate III in Explosion-protected equipment overhaul Qualification
A124 UEE31011 Certificate III in Fire Protection Control Qualification
D731 UEG20411 Certificate II in Gas Industry Cylinder Operations Qualification
W991 UEG30110 Certificate III in Gas Industry Operations Qualification
D730 UEG20311 Certificate II in Gas Industry Transmission Pipeline Construction Qualification
D735 UEG50211 Diploma of Gas Supply Industry Operations Qualification
J837 UEG60114 Advanced Diploma of Gas Supply Industry Operations Qualification
BDY6 UEG40118 Certificate IV in Gas Supply Industry Operations Qualification
J836 UEG50114 Diploma of Gas Supply Industry Operations Qualification
BDY4 UEG60118 Advanced Diploma of Gas Supply Industry Operations Qualification
BDY5 UEG50118 Diploma of Gas Supply Industry Operations Qualification
BDY3 UEG30118 Certificate III in Gas Supply Industry Operations Qualification
J833 UEG20114 Certificate II in Gas Supply Industry Operations Qualification
BDY2 UEG20118 Certificate II in Gas Supply Industry Operations Qualification
J835 UEG40114 Certificate IV in Gas Supply Industry Operations Qualification
J834 UEG30114 Certificate III in Gas Supply Industry Operations Qualification
AB622 UEESS00059 Hazardous Areas - Attend to Breakdowns in Hazardous Areas - Coal Mining Skill set
AC330 UEESS00128 Hazardous Areas - Classify, Audit and Report on Hazardous Areas - Coal Mining Skill set
AB781 UEESS00062 Hazardous Areas - Conduct Audit of Hazardous Areas Installations - Coal Mining Skill set
AC735 UEESS00127 Hazardous Areas - Design and Maintain Safe Hazardous Areas Installations - Coal Mining Skill set
A151 UEE42611 Certificate IV in Hazardous areas - Electrical Qualification
W859 UEE42610 Certificate IV in Hazardous areas - Electrical Qualification
AB793 UEESS00113 Hazardous Areas - Electrical equipment in dust atmospheres Skill set
AC000 UEESS00114 Hazardous Areas - Electrical equipment in gas atmospheres Skill set
AC554 UEESS00115 Hazardous Areas - Electrical equipment in hazardous areas - pressurisation Skill set
W832 UEE31710 Certificate III in Hazardous areas - Electrician Qualification
AB741 UEESS00068 Hazardous Areas - Install Explosion-Protected Equipment and Wiring Systems - Coal Mining Skill set
W833 UEE31810 Certificate III in Hazardous areas - Instrumentation Qualification
AC690 UEESS00069 Hazardous Areas - Maintain Equipment in Hazardous Areas - Coal Mining Skill set
A154 UEE43211 Certificate IV in Industrial Automation and Control Qualification
A140 UEE40911 Certificate IV in Industrial Electronics and Control Qualification
A167 UEE60611 Advanced Diploma of Industrial Electronics and Control Engineering Qualification
A134 UEE40311 Certificate IV in Installation Inspection and Audits Qualification
A150 UEE42211 Certificate IV in Instrumentation and Control Qualification
A127 UEE31211 Certificate III in Instrumentation and Control Qualification
A171 UEE61511 Advanced Diploma of Instrumentation and Control Engineering Qualification